Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI PXI-6259

16-Bit, 1 MS/s (Multichannel), 1.25 MS/s (1-Channel), 32 Analog Inputs

  • Four 16-bit analog outputs (2.8 MS/s); 48 digital I/O; 32-bit counters
  • NI-MCal calibration technology for increased measurement accuracy
  • NIST-traceable calibration certificate and more than 70 signal conditioning options
  • Correlated DIO (32 clocked lines, 10 MHz); analog and digital triggering
  • Get improved measurement accuracy, resolution, and sensitivity by choosing high-accuracy M Series.
  • NI-DAQmx driver software and NI LabVIEW SignalExpress interactive data-logging software
Configure System
View Data Sheet and Specifications

The National Instruments PXI-6259 is a high-speed multifunction M Series data acquisition (DAQ) board optimized for superior accuracy at fast sampling rates. For increased measurement accuracy, consider the high-accuracy M Series devices with an 18-bit analog-to-digital converter providing a 4X resolution increase.

High-speed M Series devices incorporate advanced features such as the NI-STC 2 system controller, NI-PGIA 2 programmable amplifier, and NI-MCal calibration technology to increase performance and accuracy. High-speed M Series devices have an onboard NI-PGIA 2 amplifier designed for fast settling time at high scanning rates, ensuring 16-bit accuracy even when measuring all channels at maximum speeds. To learn more about M Series technologies, device specifications, and information on recommended cables and accessories, please refer to the data sheet and specifications.

Driver Software
M Series devices work with multiple operating systems using three driver software options including NI-DAQmx, NI-DAQmx Base, and the Measurement Hardware DDK. Browse the information in the Resources tab to learn more about driver software or download a driver. M Series devices are not compatible with the Traditional NI-DAQ (Legacy) driver.

Application Software
With NI LabVIEW, you can create custom data acquisition applications with the ease of graphical programming and power of more than 500 analysis functions and advanced programming tools. LabVIEW Full and Professional Development Systems include LabVIEW SignalExpress for interactive data logging. M Series data acquisition devices are compatible with the following versions (or later) of NI application software – LabVIEW 7.x, LabWindows™/CVI 7.x, or Measurement Studio 7.x; LabVIEW SignalExpress 1.x; or LabVIEW with the LabVIEW Real-Time Module 7.1. M Series data acquisition devices are also compatible with Visual Studio .NET, C/C++, and Visual Basic 6.

View Diagram

Select one of the following options for product configuration and pricing:

Select Module and Accessories Below »   Configure and Price a Complete PXI System »
 
Module Accessories   Chassis, Controllers, Modules Software & Services
Step 1: Verify Device and Quantity Selection
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
  NI PXI-6259      
779632-01 Standard Board
NI Recommended
5 - 10 $ 1,599.00
779119-01 Board for SCXI Control in PXI/SCXI Combination Chassis 5 - 10 $ 1,599.00

Each NI PXI-6259 requires: 2 Cables, 2 Connector Blocks

NI PXI-6259 Cable Connector Block
Step 2: Select Cable
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Connector 0
Shielded
192061-02 SHC68-68-EPM Cable (2m)
NI Recommended
1 - 3 $ 129.00
192061-01 SHC68-68-EPM Cable (1m) 1 - 3 $ 99.00
192061-0R5 SHC68-68-EPM Cable (0.5m) 5 - 10 $ 99.00
192061-10 SHC68-68-EPM Cable (10m) 5 - 10 $ 219.00
192061-05 SHC68-68-EPM Cable (5m) 5 - 10 $ 169.00
Unshielded
187252-01 RC68-68 Cable (1m) 5 - 10 $ 59.00
187252-0R5 RC68-68 Cable (0.5m) 5 - 10 $ 49.00
187252-0R25 RC68-68 Cable (0.25m) 5 - 10 $ 49.00
Connector 1
Shielded
192061-02 SHC68-68-EPM Cable (2m)
NI Recommended
1 - 3 $ 129.00
192061-01 SHC68-68-EPM Cable (1m) 1 - 3 $ 99.00
192061-0R5 SHC68-68-EPM Cable (0.5m) 5 - 10 $ 99.00
192061-10 SHC68-68-EPM Cable (10m) 5 - 10 $ 219.00
192061-05 SHC68-68-EPM Cable (5m) 5 - 10 $ 169.00
Unshielded
187252-01 RC68-68 Cable (1m) 5 - 10 $ 59.00
187252-0R5 RC68-68 Cable (0.5m) 5 - 10 $ 49.00
187252-0R25 RC68-68 Cable (0.25m) 5 - 10 $ 49.00
Step 3: Select Connector Block
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Connector 0
Screw Terminals
776844-01 SCB-68 - Shielded
NI Recommended
1 - 3 $ 299.00
BNC Termination
779556-01 BNC-2090A - Shielded, Rack Mountable 1 - 3 $ 419.00
777643-01 BNC-2110 - Shielded 1 - 3 $ 349.00
777960-01 BNC-2120 - Shielded 1 - 3 $ 399.00
779347-01 BNC-2111 - Shielded 5 - 10 $ 349.00
Screw Terminals
779475-01 SCC-68 - Unshielded 1 - 3 $ 299.00
777145-01 CB-68LP - Unshielded 1 - 3 $ 79.00
777141-01 TBX-68 Unshielded, I/O Connector Block with DIN-Rail Mounting - Unshielded 1 - 3 $ 159.00
777145-02 CB-68LPR - Unshielded 1 - 3 $ 99.00
779183-01 TB-2706 10 - 15 $ 259.00
Connector 1
Screw Terminals
776844-01 SCB-68 - Shielded
NI Recommended
1 - 3 $ 299.00
BNC Termination
779556-01 BNC-2090A - Shielded, Rack Mountable 1 - 3 $ 419.00
777643-01 BNC-2110 - Shielded 1 - 3 $ 349.00
777960-01 BNC-2120 - Shielded 1 - 3 $ 399.00
779347-01 BNC-2111 - Shielded 5 - 10 $ 349.00
Screw Terminals
779475-01 SCC-68 - Unshielded 1 - 3 $ 299.00
777145-01 CB-68LP - Unshielded 1 - 3 $ 79.00
777141-01 TBX-68 Unshielded, I/O Connector Block with DIN-Rail Mounting - Unshielded 1 - 3 $ 159.00
777145-02 CB-68LPR - Unshielded 1 - 3 $ 99.00
Step 4: Select Optional Accessories
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Other
779489-01 DAQ 7 Steps Tutorial 5 - 10 $ 95.00
SCC Modules
777459-04 SCC-TC02, Thermocouple Input Module with Screw Terminals 10 - 15 $ 179.00
777459-22 SCC-AI03, 2-Channel Isolated Analog Input 10 - 15 $ 359.00
777459-18 SCC-RTD01, 2-Channel RTD Input Module 10 - 15 $ 359.00
777459-33 SCC-CO20, 1-Channel Current Output Module (0 - 20 mA) 12 - 20 $ 279.00
Step 5: Add to Cart or Get a Quote

Guarantee your price for 30 days with an NI Instant Quote (learn more)

You have selected United States as the country where you will use the product(s) (change).

Specifications Documents


Specifications Summary

General 
Form FactorPXI Platform
PXI Bus TypePXI Hybrid Compatible
Operating System / TargetWindows, Real-Time, Linux, Mac OS
Measurement TypeDigital, Frequency, Quadrature encoder, Voltage
DAQ Product FamilyM Series
LabVIEW RT SupportYes
Analog Input 
Number of Channels32 SE/16 DI
Sample Rate1.25 MS/s
Resolution16 bits
Simultaneous SamplingNo
Maximum Voltage Range-10..10 V
      Range Accuracy1920 µV
      Range Sensitivity112 µV
Minimum Voltage Range-100..100 mV
      Range Accuracy52 µV
      Range Sensitivity6 µV
Number of Ranges7
On-Board Memory4095 samples
Analog Output 
Number of Channels4
Update Rate2.86 MS/s
Resolution16 bits
Maximum Voltage Range-10..10 V
      Range Accuracy2080 µV
Minimum Voltage Range-5..5 V
      Range Accuracy1045 µV
Current Drive (Channel/Total)5 mA
Digital I/O 
Number of Channels48 DIO
TimingHardware, Software
Maximum Clock Rate10 MHz
Logic LevelsTTL
Maximum Input Range0..5 V
Maximum Output Range0..5 V
Input Current FlowSinking, Sourcing
Programmable Input FiltersYes
Output Current FlowSinking, Sourcing
Current Drive (Channel/Total)24 mA/1 A
Watchdog TimerNo
Supports Programmable Power-Up States?Yes
Supports Handshaking I/O?No
Supports Pattern I/O?Yes
Counter/Timers 
Number of Counter/Timers2
Resolution32 bits
Maximum Source Frequency80 MHz
Minimum Input Pulse Width12.5 ns
Logic LevelsTTL
Maximum Range0..5 V
Timebase Stability50 ppm
GPS SynchronizationNo
Pulse GenerationYes
Buffered OperationsYes
Debouncing/Glitch RemovalYes
Number of DMA Channels2
Timing/Triggering/Synchronization 
Synchronization Bus (RTSI)Yes
TriggeringAnalog, Digital

System Assurance Programs

Reduce your setup time and total cost of ownership, and get a system you can use out of the box with National Instruments system assurance programs. System assurance programs include:

  • Installation and integration test of all individual hardware
  • Courtesy installation of system driver sets and application development environments
  • Three-year warranty and calibration coverage
  • Custom documentation plus a custom restore and startup utility

This service is only available for PXI, NI CompactRIO, and NI Compact FieldPoint systems.

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support