Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI SCXI-1112

8-Channel Thermocouple Input Module

  • Cold-junction compensation per channel
  • Onboard calibration reference
  • NI-DAQmx Measurement Services software to simplify configuration and measurements
  • Instrumentation amplifier per channel
  • Open thermocouple detection LEDs
  • SCXI-1600 (USB) is recommended for controlling this module; also compatible with M Series
Data Sheet  |   Configure System popup

Use SCXI Advisor to configure an SCXI data acquisition system based on this module.

The National Instruments SCXI-1102 and SCXI-1112 are designed for high-accuracy thermocouple measurements. They share a common architecture where each input channel includes an instrumentation amplifier and a 2 Hz lowpass filter. With this architecture, you can scan the NI SCXI-1102 or SCXI-1112 analog input channels along with the input channels of other modules at rates up to 333 kS/s (3 µs per channel). You can also scan the cold-junction compensation sensor along with other input channels. The SCXI-1102 can also acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals. Each module can multiplex its channels into a single channel of the DAQ device, and you can add modules to increase channel count.

The SCXI-1600USB data acquisition module can be used in conjunction with this module to create a completely plug-and-play USB data acquisition system. An SCXI chassis is required to house the SCXI-1600 and assorted SCXI modules for a particular system. The SCXI-1000 chassis is capable of holding up to four modules while the SCXI-1001 can hold up to 12.

most popular item most popular item(s)
Part Number Description Est Ship  US Dollars Qty
NI SCXI-1112
776572-12SCXI-1112 8 ch Thermocouple Input Module10 - 15$ 829.00
745688-J10J-Type Minithermocouple Plug (QTY 10)12 - 20$ 49.00
745690-J002J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 2 m12 - 20$ 29.00
745687-J030J-Type Thermocouple Wire (32 deg F to 900 deg F) 30 m12 - 20$ 109.00
745688-K10K-Type Minithermocouple Plug (QTY 10)12 - 20$ 49.00
745690-K002K-Type Thermocouples Wire, Fiberglass (32deg F to 900deg F) 2 m12 - 20$ 29.00
745687-K030K-Type Thermocouple Wire (32 deg F to 900 deg F) 30 m12 - 20$ 109.00
Complete your SCXI Data Acquisition System with USB Connectivity
776572-1600NI SCXI-1600, USB Data Acquisition and Control Module5 - 10$ 1,199.00
776570-01most popular item SCXI-1000 4-Slot Chassis, U.S. 120 VAC5 - 10$ 829.00

Guarantee your price for 30 days with an NI Instant Quote (learn more)

You have selected the United States as the country where you will use the product(s) (change).

Specifications Documents


Specifications Summary

General 
Form FactorSCXI
Operating System / TargetWindows, Real-Time, Linux
Measurement TypeThermocouple
LabVIEW RT SupportYes
Analog Input 
Number of Channels8 DI
Sample Rate333 kS/s
Simultaneous SamplingNo
Input Impedance1 GOhm
Maximum Voltage Range-100..100 mV
Signal ConditioningCold-junction compensation, Low-pass filtering, Open thermocouple
Available Filters2 Hz
Analog Output 
Number of Channels0
Digital I/O 
Number of Channels0
Counter/Timers 
Number of Counter/Timers0
Timing/Triggering/Synchronization 
TriggeringAnalog, Digital
Triggers cDAQ ChassisNo

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support