Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI USB-6216

16-Bit, 400 kS/s Isolated M Series MIO DAQ, Bus-Powered

Configure Page for: Print PDF Rich Text
  • 16 analog inputs (16-bit, 400 kS/s)
  • 2 analog outputs (16-bit, 250 kS/s); 32 digital I/O; two 32-bit counters
  • 60 V, CAT I isolation (1000 Vrms, 5 s withstand) for improved accuracy and safety
  • NI signal streaming for sustained high-speed data streams over USB; OEM version available
  • Compatible with LabVIEW, ANSI C/C++, C#, Visual Basic .NET, and Visual Basic 6.0
  • NI-DAQmx driver software and NI LabVIEW SignalExpress LE interactive data-logging software


The NI USB-6216 is a bus-powered USB M Series multifunction data acquisition (DAQ) module optimized for superior accuracy at fast sampling rates. It offers 16 analog inputs; 400 kS/s sampling rate; two analog outputs; 32 digital I/O lines; four programmable input ranges (±0.2 to ±10 V) per channel; digital triggering; and two counter/timers. The module features 60 V, CAT I isolation for improved accuracy and safety.

The USB-6216 is designed specifically for mobile or space-constrained applications. Plug-and-play installation minimizes configuration and setup time, while direct screw-terminal connectivity keeps costs down and simplifies signal connections. This product does not require external power.

The module also features NI signal streaming technology, which gives you DMA-like bidirectional high-speed streaming of data across the USB bus. For more information about NI signal streaming, view the Resources tab.

Driver Software
NI-DAQmx driver and measurement services software provides easy-to-use configuration and programming interfaces with features such as the DAQ Assistant to help reduce development time. M Series DAQ devices are not compatible with the Traditional NI-DAQ (Legacy) driver.

Application Software
Every M Series DAQ device includes a copy of NI LabVIEW SignalExpress LE data-logging software, so you can quickly acquire, analyze, and present data without programming. In addition to LabVIEW SignalExpress, M Series DAQ devices are compatible with the following versions (or later) of NI application software – LabVIEW 7.1, LabWindows™/CVI 7.x, or Measurement Studio 7.x. M Series DAQ devices are also compatible with Visual Studio .NET, ANSI C/C++, and Visual Basic 6.0.

The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

Specifications Documents

View Data Sheet

Specifications Summary

General
Product Name USB-6216
Product Family Multifunction Data Acquisition
Form Factor USB
Part Number 780170-01 , 780108-01
Operating System/Target Windows
DAQ Product Family M Series
Measurement Type Quadrature encoder , Voltage
Isolation Type Bank Isolation
RoHS Compliant Yes
USB Power Bus-Powered
Analog Input
Channels 16 , 8
Single-Ended Channels 16
Differential Channels 8
Resolution 16 bits
Sample Rate 400 kS/s
Max Voltage 10 V
Maximum Voltage Range -10 V - 10 V
Maximum Voltage Range Accuracy 2.71 mV
Maximum Voltage Range Sensitivity 118 µV
Minimum Voltage Range -200 mV - 200 mV
Minimum Voltage Range Accuracy 0.089 mV
Minimum Voltage Range Sensitivity 5.2 µV
Number of Ranges 4
Simultaneous Sampling No
On-Board Memory 4095 samples
Analog Output
Channels 2
Resolution 16 bits
Max Voltage 10 V
Maximum Voltage Range -10 V - 10 V
Maximum Voltage Range Accuracy 3.512 mV
Minimum Voltage Range -10 V - 10 V
Minimum Voltage Range Accuracy 3.512 mV
Update Rate 250 kS/s
Current Drive Single 2 mA
Current Drive All 4 mA
Digital I/O
Bidirectional Channels 32
Input-Only Channels 0
Output-Only Channels 0
Timing Software
Logic Levels TTL
Input Current Flow Sinking , Sourcing
Output Current Flow Sinking , Sourcing
Programmable Input Filters No
Supports Programmable Power-Up States? Yes
Current Drive Single 16 mA
Current Drive All 50 mA
Watchdog Timer No
Supports Handshaking I/O? No
Supports Pattern I/O? No
Maximum Input Range 0 V - 5.25 V
Maximum Output Range 0 V - 3.8 V
Counter/Timers
Counters 2
Buffered Operations Yes
Debouncing/Glitch Removal Yes
GPS Synchronization No
Maximum Range 0 V - 5.25 V
Max Source Frequency 80 MHz
Pulse Generation Yes
Resolution 32 bits
Timebase Stability 50 ppm
Logic Levels TTL
Physical Specifications
Length 16.9 cm
Width 9.4 cm
Height 3.1 cm
I/O Connector Screw terminals
Timing/Triggering/Synchronization
Triggering Digital

NI USB-6216 Complete Package

Each NI USB-6216 requires:

NI USB-6216 Software

Roll over icons above to learn why you need each item in the package.

NI USB-6216 and Accessories

Hardware Subtotal: $ 1,335
NI USB-6216
780108-01 Qty $ 1,335 each
780170-01 Qty $ 1,335 each

 
Optional Accessories Hide
Qty $ 64 each
Qty $ 57 each
Qty $ 175 each
DIN Rail Mounting Kit - 779689-01
Qty $ 31 each
Qty $ 290 each

Software

Software Subtotal: $ 0
Note : You should only purchase this device without software if you already own compatible application software. [View Full List]
LabVIEW Full Development System for Windows (English) , 1 year SSP - 776670-35 Qty $ 2,699 each
LabVIEW Application Builder for Windows - 776675-35 Qty $ 999 each
Change Software
Learn about all compatible software and get recommendations based on your needs.
Package Price: $ 1,335
Add to Cart >>
Guarantee your price for 30 days (learn more) Instant Quote
You need software to interface with your hardware and to collect, analyze, present, and store your measurements. This board is compatible with a variety of programming languages, including LabVIEW, C/C++, Visual Basic, and .NET. LabVIEW provides the easiest integration with all of your NI hardware and is recommended to maximize your hardware investment.

You have selected United States as the country where you will use the product(s) (change).

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support