2.5 GHz 75 Ω Terminated 4x1 Mux (Insertion Loss <2.0 dB)

  • 75 Ω characteristic impedance
  • 2.5 GHz bandwidth
  • Insertion loss at 2.5 GHz <2.0 dB (typical <1.6 dB)
  • VSWR at 2.5 GHz <1.75 (typical <1.5)
  • Onboard relay counting
  • Use NI Switch Executive for calibrating losses on each PXI-2555 channel
  • Data Sheet  |   Configure System popup

View Diagram

Select one of the following options for product configuration and pricing:

Select Module and Accessories Below »   Configure and Price a Complete PXI System »
 
Module Accessories   Chassis, Controllers, Modules Software & Services
Step 1: Verify Device and Quantity Selection
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
778572-55 NI PXI-2555 -- For price, select country  

Each NI PXI-2555 requires: 5 Cables

NI PXI-2555 Cable
Step 2: Select Cable
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Shielded
197211-0R3 Mini-75 Ohm SMB Plug to Mini-75 Ohm SMB Plug (0.3m)
NI Recommended
-- For price, select country  
197211-01 Mini-75 Ohm SMB Plug to Mini-75 Ohm SMB Plug (1m) -- For price, select country  
Step 3: Select Optional Accessories
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Software
778546-09 NI Switch Executive Development System + 1 Yr SSP -- For price, select country  
Step 4: Add to Cart or Get a Quote

Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information

The National Instruments PXI-2555 is a 4x1 high-frequency terminated multiplexer switch module suited for routing signals from DC to 2.5 GHz in 75 Ω RF applications. It can switch up to 30 Vrms or 500 mA, at a maximum power rating of 10 W. The internal termination of the NI PXI-2555, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in video RF applications where such reflections can damage the source. The module also provides users with excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation; you can use the onboard relay-count-tracking feature to predict relay lifetime and reduce unexpected system downtime.

Note: The bandwidth specification of a switch module, which is not an absolute specification, is determined by vendor standards. Although higher frequency signals can be routed through this switch module, they will encounter more degradation than those at lower frequencies. In order to determine the best switch module for your application review the insertion loss, VSWR, and isolation specifications of the product for the bandwidth of your application. For more information on choosing the right RF switch for your application, review the ‘Guide to Selecting an RF Switch’ linked in the 'Resources' section of this page.

Specifications Documents


Specifications Summary

General 
Form FactorPXI
OS SupportWindows, Real-Time, Linux, Mac OS
Switch TypeMultiplexer, RF
Relay TypeElectromechanical
ConnectivityCables
Product CertificationsC-Tick, CE, FCC Part 15, UL - Product Safety
Input Characteristics 
Multiplexer Configurations4x1, 1-wire
Maximum Switching Voltage DC (Pollution Degree 2)30 VDC
Maximum Switching Voltage DC (Pollution Degree 1)30 VDC
Maximum Switching Voltage AC30 Vrms
Maximum Switching Current0.5 A
Maximum Carry Current0.5 A
Maximum Switching Power10 W
Bandwidth2.5 GHz
Relay Count TrackingYes
Voltage CategoryCAT I
Path Resistance (Typical)0.35 GOhm
Dynamic Characteristics 
VSWR (Typical)1.15 @ 1 GHz, 1.4 @ 2 GHz, 1.5 @ 2.5 GHz
Isolation (Typical)47 dB
Insertion Loss (Typical)1.6 dB
TerminatedYes
Characteristic Impedance75 Ohm
Mechanical Relay Life1000000 cycles
Scan Rate45 cycles/s
Timing/Triggering/Synchronization 
Synchronization Bus (RTSI)Yes
TriggeringAnalog
External ClockingYes
Physical Specifications 
Length16 cm
Width10 cm
Height2 cm
I/O ConnectorSMB female

System Assurance Programs

Reduce your setup time and total cost of ownership, and get a system you can use out of the box with National Instruments system assurance programs. System assurance programs include:

  • Installation and integration test of all individual hardware
  • Courtesy installation of system driver sets and application development environments
  • Three-year warranty and calibration coverage
  • Custom documentation plus a custom restore and startup utility

This service is only available for PXI, NI CompactRIO, and NI Compact FieldPoint systems.

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support