- 50 Ω characteristic impedance
- 2.7 GHz bandwidth
- Insertion loss at 2.7 GHz <0.9 dB (typical <0.6 dB)
- VSWR at 2.7 GHz <1.5 (typical <1.35)
- Onboard relay counting
- Use NI Switch Executive for calibrating losses on each PXI-2548 channel
Data Sheet |
Configure System
View Diagram
Select one of the following options for product configuration and pricing:
Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information
The National Instruments PXI-2548 is a general-purpose switch module that features four (quad) independent SPDT relays suited for routing signals from DC to 2.7 GHz in 50 Ω RF applications. It can switch up to 30 Vrms or 500 mA at a maximum power rating of 10 W. Use the NI PXI-2548 to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high-channel-count multiplexers. The module also features excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation; and its onboard relay-count-tracking feature can be used to predict relay lifetime and reduce unexpected system downtime.
Note: The bandwidth specification of a switch module, which is not an absolute specification, is determined by vendor standards. Although higher frequency signals can be routed through this switch module, they will encounter more degradation than those at lower frequencies. In order to determine the best switch module for your application, review the insertion loss, VSWR, and isolation specifications of the product for the bandwidth of your application. For more information on choosing the right RF switch for your application, review the ‘Guide to Selecting an RF Switch’ linked in the 'Resources' section of this page.
Additional Product Information
Related Information
Specifications Documents
Specifications Summary
| General | | | Form Factor | PXI | | OS Support | Windows, Real-Time, Linux, Mac OS, Unix, Other | | Switch Type | General-Purpose Relay, RF | | Relay Type | Electromechanical | | Connectivity | Cables | | Product Certifications | C-Tick, CE, FCC Part 15, UL - Product Safety |
| Input Characteristics | | | Number of Relays | 4 SPDT | | Maximum Switching Voltage DC (Pollution Degree 2) | 30 VDC | | Maximum Switching Voltage DC (Pollution Degree 1) | 30 VDC | | Maximum Switching Voltage AC | 30 Vrms | | Maximum Switching Current | 0.5 A | | Maximum Carry Current | 0.5 A | | Maximum Switching Power | 10 W | | Bandwidth | 2.7 GHz | | Relay Count Tracking | Yes | | Voltage Category | CAT I | | Path Resistance (Typical) | 0.25 Ohm |
| Dynamic Characteristics | | | VSWR (Typical) | 1.15 @ 1.5 GHz, 1.35 @ 2.7 GHz | | Isolation (Typical) | 39 dB | | Insertion Loss (Typical) | 0.6 dB | | Terminated | No | | Characteristic Impedance | 50 Ohm | | Mechanical Relay Life | 1000000 cycles | | Scan Rate | 45 cycles/s |
| Timing/Triggering/Synchronization | | | Synchronization Bus (RTSI) | Yes | | Triggering | Analog | | External Clocking | No |
| Physical Specifications | | | Length | 16 cm | | Width | 10 cm | | Height | 2 cm | | I/O Connector | SMA female |
Factory Installation
Reduce your setup time with National Instruments installation services and get a system you can use out of the box. Factory installation services include:
- Installation of all individual hardware and software components as well as full testing to eliminate conflicts
- Custom documentation plus a custom restore and startup utility
- 2-year warranty and calibration coverage
This service is only available for PXI, CompactRIO, and Compact FieldPoint systems.
Extended Warranties
National Instruments designs and manufactures all products to minimize failures, but we know unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase covering any repair costs for up to three years.
- Significant cost savings compared to individual repair incidents
- Fault location, diagnostics, and repair by NI any time the system product fails
- All parts and labor costs covered as well as any adjustments needed to bring the hardware back to manufacturing specifications
Calibration
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many of our measurement products.
Training
NI training is the fastest, most certain route to productivity with NI tools and successful application development.
Repair Services
- You can return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to bring the hardware back to manufacturing specifications.
- Contact us to obtain a Return Material Authorization (RMA) form and shipping instructions
- View your RMA support request status online
- Register your product
Technical Support
www.ni.com/support
|