Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI PXI-2599

26.5 GHz Dual SPDT Relays

  • 50 Ω characteristic impedance
  • Design based on RADIALL R570 series microwave switches
  • Ability to store RF path calibration information with NI Switch Executive
  • 26.5 GHz bandwidth electromechanical relays
  • Onboard relay count tracking
  • <1 dB of insertion loss at 26.5 GHz
  • Data Sheet  |   Configure System popup

View Diagram

Select one of the following options for product configuration and pricing:

Select Module and Accessories Below » Configure and Price a Complete PXI System »
 
Module Accessories   Chassis, Controllers, Modules Software & Services
Step 1: Verify Device and Quantity Selection
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
778572-99 NI PXI-2599 -- For price, select country  

Each NI PXI-2599 requires: 6 Cables

NI PXI-2599 Cable
Step 2: Select Cable
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Shielded
763443-01 SMA100 Cable (15cm)
NI Recommended
-- For price, select country  
763444-01 SMA100 Cable (45cm) -- For price, select country  
Step 3: Select Optional Accessories
Part
Number
Description Est Ship Days Glossary Definition US Dollars
(change)
Qty
Other
779670-00 NI PXI-5650 -- For price, select country  
Software
778546-09 NI Switch Executive Development System + 1 Yr SSP -- For price, select country  
Step 4: Add to Cart or Get a Quote

Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information

The National Instruments PXI-2599 is a dual SPDT relay switch module designed for routing RF or microwave signals in automated test applications. While designed to operate with less than 1 dB insertion loss up to 26.5 GHz, the NI PXI-2599 appears almost invisible to signals at much lower frequencies as well. Use the PXI-2599 for basic signalrouting or inserting and removing components in a signal path. Thismodule is also well-suited for passing high-order harmonics from RFupconverters, such as the NI PXI-5670 2.7 GHz RF signal generator, orrouting multiple sources to RF downconverters, such as theNI PXI-5660 2.7 GHz RF signal analyzer.

Specifications Documents


Specifications Summary

General 
Form FactorPXI
OS SupportWindows, Real-Time, Linux
LabVIEW RT SupportYes
Switch TypeGeneral-Purpose Relay, RF
Relay TypeElectromechanical
ConnectivityCables
Product CertificationsC-Tick, CAN/CSA, CE, FCC Part 15, IEC, UL - Product Safety
Input Characteristics 
Number of Relays2 SPDT
Maximum Switching Voltage AC90 Vrms
Maximum Switching Current1.73 Arms
Maximum Carry Current1.73 Arms
Maximum Switching Power150 W
Bandwidth26.5 GHz
Relay Count TrackingYes
Voltage CategoryCAT I
Dynamic Characteristics 
VSWR (Typical)1.2 @ 3 GHz
Isolation (Typical)80 dB
Insertion Loss (Typical)0.2 dB
TerminatedNo
Characteristic Impedance50 Ohm
Mechanical Relay Life1 x 108 cycles
Scan Rate5 cycles/s
Timing/Triggering/Synchronization 
Synchronization Bus (RTSI)Yes
TriggeringDigital
External ClockingNo
Physical Specifications 
Length16 cm
Width10 cm
Height2 cm
I/O ConnectorSMA female

Factory Installation

Reduce your setup time with National Instruments installation services and get a system you can use out of the box. Factory installation services include:

  • Installation of all individual hardware and software components as well as full testing to eliminate conflicts
  • Custom documentation plus a custom restore and startup utility
  • 2-year warranty and calibration coverage

This service is only available for PXI, CompactRIO, and Compact FieldPoint systems.

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, but we know unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase covering any repair costs for up to three years.

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to bring the hardware back to manufacturing specifications

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many of our measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

  • You can return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to bring the hardware back to manufacturing specifications.
  • Contact us to obtain a Return Material Authorization (RMA) form and shipping instructions
  • View your RMA support request status online
  • Register your product

Technical Support

www.ni.com/support