Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI USB-9215A

Portable USB-Based DAQ with Simultaneous Sampling

  • 4 channels of 16-bit simultaneously sampled analog input
  • Plug-and-play connectivity via USB
  • Sampling rates at 100 kS/s per channel
  • Small, portable devices (12.1 by 8.6 by 2.5 cm)
  • Includes NI-DAQmx driver software and LabVIEW SignalExpress LE for Windows
  • Includes NI-DAQmx Base driver software for Linux® and Mac
  • Data Sheet

Part Number Description Est Ship  US Dollars Qty
Devices and Common Accessory Set
779434-01USB-9215A 4 ch, +/- 10 V, 100kS/s/ch, 16-Bit, SS AI, Windows--For prices, Select Country 
779435-01USB-9215A BNC 4 ch +/- 10V, 100kS/s/ch, 16-Bit, SS AI for Windows--For prices, Select Country 
780101-01USB-9215A 4-ch, 16-bit Analog Input Module for Linux and Mac--For prices, Select Country 
780102-01USB-9215A 4-ch, 16-bit BNC Analog Input Module for Linux and Mac--For prices, Select Country 
Optional Accessories
777550-01USB/PCMCIA Cable Strain Relief for Laptop--For prices, Select Country 
 
 

Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information

The NI USB-9215A data acquisition module features integrated signal conditioning that provides plug-and-play connectivity via USB for faster setup and measurements. It offers four channels of simultaneously sampled voltage inputs with 16-bit accuracy to provide minimal phase delay when scanning multiple channels. With both screw-terminal and BNC connector options, the USB-9215A is designed for flexible and low-cost signal wiring. In addition, this module includes 250 Vrms channel-to-earth ground isolation for safety, noise immunity, and high common-mode voltage range.

This USB data acquisition module is compatible with Microsoft Windows OSs when using NI-DAQmx driver software, and Mac OS X and Linux OSs when using NI-DAQmx Base driver software. This USB data acquisition module is not compatible with the Traditional NI-DAQ (Legacy) driver.

Every NI USB data acquisition module includes a copy of NI LabVIEW SignalExpress LE for Windows so you can quickly acquire, analyze, and present data without programming. In addition to LabVIEW SignalExpress, USB data acquisition modules are compatible with the following versions (or later) of NI application software – LabVIEW 7.x, LabWindows™/CVI 7.x, or Measurement Studio 7.x; or LabVIEW with the LabVIEW 7.1 Real-Time Module. USB data acquisition modules are also compatible with ANSI C/C++, C#, Visual Studio .NET, and Visual Basic 6.0.

The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.

Specifications Documents


Specifications Summary

General 
Form FactorUSB
OS SupportWindows, Linux, Mac OS
Isolation TypeBank Isolation
Analog Input 
Number of Channels4 DI
Sample Rate100 kS/s/ch
Resolution16 bits
Simultaneous SamplingYes
Maximum Voltage Range-10..10 V
      Range Accuracy0.14 V
Minimum Voltage Range-10..10 V
      Range Accuracy0.14 V
Number of Ranges1
On-Board Memory0 samples
Analog Output 
Number of Channels0
Digital I/O 
Number of Channels0
Counter/Timers 
Number of Counter/Timers0
Timing/Triggering/Synchronization 
Physical Specifications 
Length14 cm
Width8.6 cm
Height2.5 cm
I/O ConnectorBNC connectors, Screw terminals

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, but we know unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase covering any repair costs for up to three years.

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to bring the hardware back to manufacturing specifications

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many of our measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

  • You can return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to bring the hardware back to manufacturing specifications.
  • Contact us to obtain a Return Material Authorization (RMA) form and shipping instructions
  • View your RMA support request status online
  • Register your product

Technical Support

www.ni.com/support