Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI PXI-6040E

500 kS/s (1-Channel), 250 kS/s (Multichannel), 12-Bit, 16-Analog-Input Multifunction DAQ

  • FREE award-winning global services and support at ni.com/support
  • NIST-traceable calibration certificate and more than 70 signal conditioning options
  • Two 12-bit analog outputs; 8 digital I/O; two 24-bit counters; analog and digital triggering
  • Consider M Series for 16-bit resolution, 1.25 MS/s, and costs similar to the PXI-6251.
  • Included NI-DAQmx driver software and additional measurement services
  • LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Basic and Visual Studio .NET integration
  • Data Sheet  |   Configure System popup

Part Number Description Est Ship  US Dollars Qty
Products and Accessories
777484-01NI PXI-6040E and NI-DAQ--For prices, Select Country 
778241-01TB-2705, PXI Front-mount Screw Terminal Blk for E/S-Series DAQ--For prices, Select Country 
779489-01Data Acquisition: 7 Steps To Success Tutorial Kit--For prices, Select Country 
SCC Signal Conditioning Common Configurations
777459-04SCC-TC02 Thermocouple Input Module, with Screw Terminals--For prices, Select Country 
777459-22SCC-AI03 2 ch Isolated Analog Input (10V, 10 kHz)--For prices, Select Country 
777459-16SCC-SG04, 2 Channel, Full Bridge--For prices, Select Country 
778018-01SC-2345 (panelettes, rear conn, power from DAQ device)--For prices, Select Country 
 
 

Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information

National Instruments recommends M Series DAQ and NI-DAQmx driver software for new applications. Increase resolution 16 times, double sampling speeds, get more I/O, and improve performance with the 16-bit, 1.25 MS/s PXI-6251.

Add sensor and high-voltage measurement capability to your E Series device with NI SCC or SCXI signal conditioning. The National Instruments PXI-6040E uses E Series technology to deliver high-performance, reliable data acquisition capabilities to meet a wide range of application requirements. You get 500 kS/s (1-channel, 250 kS/s multichannel), 12-bit resolution on 16 single-ended analog inputs. Depending on your type of hard drive, this module can stream to disk at rates up to 250 kS/s. Using NI hardware, you have flexible OS, application development environment, and application software choices.

Complete your DAQ system with NI signal conditioning to measure virtually any type of sensor and voltage.

Specifications Documents


Specifications Summary

General 
Form FactorPXI
OS SupportWindows, Real-Time, Linux, Mac OS
DAQ Product FamilyE Series
LabVIEW RT SupportYes
Analog Input 
Number of Channels16 SE/8 DI
Sample Rate500 kS/s
Resolution12 bits
Simultaneous SamplingNo
Maximum Voltage Range-10..10 V
      Range Accuracy15.373 mV
Minimum Voltage Range-50..50 mV
      Range Accuracy0.1 mV
Number of Ranges15
On-Board Memory512 samples
Analog Output 
Number of Channels2
Update Rate1 MS/s
Resolution12 bits
Maximum Voltage Range-10..10 V
      Range Accuracy8.127 mV
Minimum Voltage Range0..10 V
      Range Accuracy5.685 mV
Current Drive (Channel/Total)5 mA
Digital I/O 
Number of Channels8 DIO
TimingSoftware
Logic LevelsTTL
Maximum Input Range0..5 V
Maximum Output Range0..5 V
Input Current FlowSinking, Sourcing
Programmable Input FiltersNo
Output Current FlowSinking, Sourcing
Current Drive (Channel/Total)24 mA/192 mA
Watchdog TimerNo
Supports Programmable Power-Up States?No
Supports Handshaking I/O?No
Supports Pattern I/O?No
Counter/Timers 
Number of Counter/Timers2
Resolution24 bits
Maximum Source Frequency20 MHz
Minimum Input Pulse Width10 ns
Logic LevelsTTL
Maximum Range0..5 V
Timebase Stability100 ppm
GPS SynchronizationNo
Pulse GenerationYes
Buffered OperationsYes
Debouncing/Glitch RemovalNo
Number of DMA Channels1
Timing/Triggering/Synchronization 
Synchronization Bus (RTSI)Yes
TriggeringAnalog, Digital
Physical Specifications 
Length16 cm
Width10 cm
I/O Connector68-pin male 0.050 D-type

Factory Installation

Reduce your setup time with National Instruments installation services and get a system you can use out of the box. Factory installation services include:

  • Installation of all individual hardware and software components as well as full testing to eliminate conflicts
  • Custom documentation plus a custom restore and startup utility
  • 2-year warranty and calibration coverage

This service is only available for PXI, CompactRIO, and Compact FieldPoint systems.

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, but we know unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase covering any repair costs for up to three years.

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to bring the hardware back to manufacturing specifications

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many of our measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

  • You can return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to bring the hardware back to manufacturing specifications.
  • Contact us to obtain a Return Material Authorization (RMA) form and shipping instructions
  • View your RMA support request status online
  • Register your product

Technical Support

www.ni.com/support