NI USB-6008

12-Bit, 10 kS/s Low-Cost Multifunction DAQ

  • 8 analog inputs (12-bit, 10 kS/s)
  • 2 analog outputs (12-bit, 150 S/s); 12 digital I/O; 32-bit counter
  • Bus-powered for high mobility; built-in signal connectivity
  • OEM version available
  • Compatible with LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Studio .NET
  • NI-DAQmx driver software and NI LabVIEW SignalExpress LE interactive data-logging software

The National Instruments USB-6008 provides basic data acquisition functionality for applications such as simple data logging, portable measurements, and academic lab experiments. It is affordable for student use, but powerful enough for more sophisticated measurement applications. Use the NI USB-6008 with the included ready-to-run data logger software to begin taking basic measurements in minutes, or program it using LabVIEW or C and the included NI-DAQmx Base measurement services software for a custom measurement system.

To supplement simulation, measurement, and automation theory courses with practical experiments, NI developed a USB-6008 Student Kit that includes a copy of the LabVIEW Student Edition. These kits are exclusively for students, giving them a powerful, low-cost, hands-on learning tool. Visit the NI academic products page for more details.

For faster sampling, more accurate measurements, and higher channel count, consider the NI USB-6210 and NI USB-6211 high-performance USB data acquisition devices.

Every USB data acquisition module includes a copy of NI LabVIEW SignalExpress LE so you can quickly acquire, analyze and present data without programming. In addition to LabVIEW SignalExpress, USB data acquisition devices are compatible with the following versions (or later) of NI application software – LabVIEW 7.x, LabWindows™/CVI 7.x, or Measurement Studio 7.x. USB data acquisition modules are also compatible with Visual Studio .NET, C/C++, and Visual Basic 6.

NI USB-6008 Complete Package

Each NI USB-6008 requires:

NI USB-6008 Software

Roll over icons above to learn why you need each item in the package.

NI USB-6008 and Accessories

Hardware Subtotal: $ 169
NI USB-6008 - 779051-01 Qty $ 169 each
USB 6008/09 Accessory Kit - 779371-01 Qty $ 29 each
USB 6000 Series Prototyping Accessory - 779511-01 Qty $ 29 each

Software

Software Subtotal: $ 0
LabVIEW Signal Express for Windows (English) - 779037-35 Qty $ 749 each
Note : You should only purchase this device without software if you already own compatible application software. View Compatible Application Software | Compare to LabVIEW SignalExpress Limited Edition [Close]
Note : This software is required to use null. You should purchase null without a LabVIEW Development System only if you already own LabVIEW Base or Full for Windows version 8.6.1 or later. Upgrade Your Development System Now [Close]
Change Software
Learn about other compatible software, OS, and language options.
Package Price: $ 169
  Add to Cart >>
Guarantee your price for 30 days (learn more)Instant Quote
 

You have selected United States as the country where you will use this product(s) (change)

Specifications Documents


Specifications Summary

General
Product Name USB-6008
Product Family Multifunction Data Acquisition
Form Factor USB
Operating System/Target Windows , Linux , Mac OS , Pocket PC
DAQ Product Family B Series
Measurement Type Voltage
RoHS Compliant Yes
Analog Input
Channels 8 , 4
Single-Ended Channels 8
Differential Channels 4
Resolution 12 bits
Sample Rate 10 kS/s
Max Voltage 10.0 V
Maximum Voltage Range 10.0 , -10.0 V
Maximum Voltage Range Accuracy 138 mV
Minimum Voltage Range 1 V , -1 V
Minimum Voltage Range Accuracy 37.500 mV
Number of Ranges 8
Simultaneous Sampling No
On-Board Memory 512 B
Analog Output
Channels 2
Resolution 12 bits
Max Voltage 5.0 V
Maximum Voltage Range 5.0 , 0.0 V
Maximum Voltage Range Accuracy 7 mV
Minimum Voltage Range 5.0 , 0.0 V
Minimum Voltage Range Accuracy 7 mV
Update Rate 150 S/s
Current Drive Single 5 mA
Current Drive All 10 mA
Digital I/O
Bidirectional Channels 12
Input-Only Cannels 0
Output-Only Channels 0
Number of Channels 12 , 0 , 0
Timing Software
Logic Levels TTL
Input Current Flow Sinking , Sourcing
Output Current Flow Sinking , Sourcing
Programmable Input Filters No
Supports Programmable Power-Up States? No
Current Drive Single 8.500 mA
Current Drive All 102 mA
Watchdog Timer No
Supports Handshaking I/O? No
Supports Pattern I/O? No
Maximum Input Range 5.0 , 0.0 V
Maximum Output Range 5.0 , 0.0 V
Counter/Timers
Counters 1
Buffered Operations No
Debouncing/Glitch Removal No
GPS Synchronization No
Maximum Range 5.0 , 0.0 V
Max Source Frequency 5 MHz
Minimum Input Pulse Width 100 ns
Pulse Generation No
Resolution 32 bits
Timebase Stability 50.0 ppm
Logic Levels TTL
Physical Specifications
Length 8.510 cm
Width 8.180 cm
Height 2.310 cm
I/O Connector Screw terminals

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support


NI USB Low-Cost Multifunction DAQ Application Demos

The USB-6008 provides an excellent entry point for data acquisition applications. View the following videos to see a similar product in action with NI LabVIEW. The videos feature the USB-6009, with higher sampling rate and resolution than the USB-6008. To realize the maximum performance cited in the video, see the USB-6009.