For engineers and scientists who need a high-power PXI chassis with reduced acoustic noise emissions for office, laboratory, and educational environments, National Instruments offers the NI PXI-1031 4-slot PXI chassis with sound pressure levels as low as 40 dBA (per ISO 7779 at operator position). With its enhanced cooling capacity, 300 W universal AC power supply, and HALT-tested chassis design, the PXI-1031 meets the demanding cooling and power requirements of today's high-performance PXI applications. To configure a system with the PXI-1031, visit ni.com/pxiadvisor.
Remote Power Inhibit Control and Voltage Monitoring
No
Total Available Power
400 W
Input Voltage Range
100 V
-
240 V
Input Frequency Range
50 Hz
-
60 Hz
Field-replaceable Power Supply
No
Auto Fan Sound Pressure Level
35 dBA
Auto Fan Sound Power
51.8 dBA
High Fan Sound Pressure Level
50 dBA
High Fan Sound Power
57.5 dBA
Auto/High Fan Selector
Yes
Number of Fans
1
Fan Capacity
86 cfm
Per-slot Cooling Capacity
86 cfm
Physical Specifications
Length
25.71 cm
Width
21.28 cm
Height
17.7 cm
I/O Connector
BNC connectors
Minimum Operating Temperature
0 °C
Maximum Operating Temperature
50 °C
Maximum Altitude
2000 m
You have selected United States as the country where you will use the product(s)
(change).
System Assurance Programs
Reduce your setup time and total cost of ownership, and get a system you can use out of the box with National Instruments system assurance programs. System assurance programs include:
Installation and integration test of all individual hardware
Courtesy installation of system driver sets and application development environments
Extended warranty and calibration coverage for up to five years
Custom documentation plus a custom restore and startup utility
This service is only available for PXI, NI CompactRIO, and NI Compact FieldPoint systems.
National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:
Significant cost savings compared to individual repair incidents
Fault location, diagnostics, and repair by NI any time the system product fails
All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.
Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.