- Scheduled for obsolescence. For new designs, consider the NI USB-6259 BNC.
- 2 analog outputs; 8 digital I/O lines; two 24-bit counters; analog triggering
- NIST-traceable calibration certificate and more than 70 signal conditioning options
- Traditional NI-DAQ (Legacy) driver software is included
- Superior integration -- LabVIEW, CVI, and Measurement Studio for Visual Basic and Visual Studio .NET
Data Sheet
- New! Compare to similar products
This device is scheduled for obsolescence. National Instruments recommends M Series DAQ and NI-DAQmx driver software for new applications. High-speed M Series devices offer a 16x improvement in analog input resolution, 32-bit counters, and a 1.25 MS/s sampling rate. M Series devices are available in PCI, PXI, PCIe, PXIe, and USB form factors with built-in BNC connectivity.
Add sensor and high-voltage measurement capability to your E Series device with SCC or SCXI signal conditioning. The National Instruments DAQPad-6070E for FireWire (IEEE 1394) uses E Series technology to deliver high-performance, reliable data acquisition capabilities to meet a wide range of application requirements. It is available in two configurations, both of which feature 250 V functional isolation from your PC and a low-profile package that fits under a laptop. The Mass Termination version features a 68-pin shielded connector to connect to signals from SCC signal conditioning modules or from our CA-1000 custom-connectivity enclosure. The BNC version features shielded BNC connectors for eight differential analog inputs, two analog outputs, and five auxiliary lines. Access to the other signals is via built-in screw terminal connections. The NI DAQPad-6070E for FireWire includes a standard IEEE 1394 cable. It can run off any 9 to 25 VDC power supply, a standard AC outlet, or the optional BP-1 battery pack, which powers the NI DAQPad-6070Efor up to 2.5 hours.
Using NI hardware, you have flexible operating system, application development environment, and application software choices.
Additional Product Information
Related Information
Specifications Documents
Specifications Summary
| General | |
| Form Factor | IEEE 1394 |
| OS Support | Windows |
| DAQ Product Family | E Series |
| Analog Input | |
| Number of Channels | 16 SE/8 DI |
| Sample Rate | 1.25 MS/s |
| Resolution | 12 bits |
| Simultaneous Sampling | No |
| Maximum Voltage Range | -10..10 V |
| Range Accuracy | 14.369 mV |
| Minimum Voltage Range | -50..50 mV |
| Range Accuracy | 0.091 mV |
| Number of Ranges | 2 |
| On-Board Memory | 512 samples |
| Analog Output | |
| Number of Channels | 2 |
| Update Rate | 1 MS/s |
| Resolution | 12 bits |
| Maximum Voltage Range | -10..10 V |
| Range Accuracy | 8.127 mV |
| Minimum Voltage Range | 0..10 V |
| Range Accuracy | 5.685 mV |
| Current Drive (Channel/Total) | 5 mA/10 mA |
| Digital I/O | |
| Number of Channels | 8 DIO |
| Timing | Software |
| Logic Levels | TTL |
| Maximum Input Range | 0..5 V |
| Maximum Output Range | 0..5 V |
| Input Current Flow | Sinking, Sourcing |
| Programmable Input Filters | No |
| Output Current Flow | Sinking, Sourcing |
| Current Drive (Channel/Total) | 24 mA/192 mA |
| Watchdog Timer | No |
| Supports Programmable Power-Up States? | No |
| Supports Handshaking I/O? | No |
| Supports Pattern I/O? | No |
| Counter/Timers | |
| Number of Counter/Timers | 2 |
| Resolution | 24 bits |
| Maximum Source Frequency | 20 MHz |
| Minimum Input Pulse Width | 10 ns |
| Logic Levels | TTL |
| Maximum Range | 0..5 V |
| Timebase Stability | 100 ppm |
| GPS Synchronization | No |
| Pulse Generation | Yes |
| Buffered Operations | Yes |
| Debouncing/Glitch Removal | No |
| Timing/Triggering/Synchronization | |
| Synchronization Bus (RTSI) | No |
| Triggering | Analog, Digital |
| Physical Specifications | |
| Length | 30.7 cm |
| Width | 25.4 cm |
| Height | 4.3 cm |
| I/O Connector | 100-pin female 0.050 D-type, BNC connectors |
Extended Warranties
National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:
- Significant cost savings compared to individual repair incidents
- Fault location, diagnostics, and repair by NI any time the system product fails
- All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications
For more information about your warranty options:
Calibration
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.
Training
NI training is the fastest, most certain route to productivity with NI tools and successful application development.
Repair Services
Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.
Technical Support
ni.com/support
|