Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI FP-RTD-124

8-Channel 4-Wire RTD Module for FieldPoint

  • Measures 2 and 4-wire RTDs or resistance
  • 50/60 Hz noise rejection
  • 16-bit resolution
  • HotPnP (plug and play) operation
  • -40 to 70 °C operating range
  • Data Sheet

Part Number Description Est Ship  US Dollars Qty
777518-124FP-RTD-124, 4 Wire RTD Input Module, 8 Channel, 16 Bit--For prices, Select Country 
745691-023-wire, 100 Ohm Platinum RTD (ready made), 2 m--For prices, Select Country 
745686-013 wire, 100 Ohm Platinum RTD (Field Cuttable Probe)--For prices, Select Country 
 
 

Please select the country where you will use the product(s) so that we can provide you with accurate pricing, availability, and purchasing information

The National Instruments FP-RTD-124 is an 8-channel input module for direct measurement of 2 and 4-wire RTD temperature sensor signals or resistance. With current excitation, signal conditioning, double-insulated isolation, input noise filtering, and a high-accuracy delta-sigma 16-bit analog-to-digital converter, the NI FP-RTD-124 delivers reliable, accurate temperature or resistance measurements. Designed from top to bottom for productivity and reliability, the module features HotPnP (plug-and-play) operation, easy configuration, self-diagnostics, and automatic scaling to engineering units. The FP-RTD-124 module comes with a NIST-traceable calibration certificate to ensure accurate, reliable analog measurements.

Specifications Documents


Specifications Summary


Extended Warranties

National Instruments designs and manufactures all products to minimize failures, but we know unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase covering any repair costs for up to three years.

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to bring the hardware back to manufacturing specifications

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many of our measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

  • You can return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to bring the hardware back to manufacturing specifications.
  • Contact us to obtain a Return Material Authorization (RMA) form and shipping instructions
  • View your RMA support request status online
  • Register your product

Technical Support

www.ni.com/support