Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

NI PCI-6030E

100 kS/s, 16-Bit, 16-Analog-Input Multifunction DAQ

  • Formerly known as PCI-MIO-16XE-10
  • Included NI-DAQmx driver software and additional measurement services
  • LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Basic and Visual Studio .NET integration
  • Consider NI M Series for 18-bit resolution, 625 kS/s, and similar costs with the PCI-6281.
  • Two 16-bit analog outputs; 8 digital I/O lines; two 24-bit counters; analog triggering
  • NIST-traceable calibration certificate and more than 70 signal conditioning options

National Instruments recommends M Series DAQ and NI-DAQmx driver software for new applications. Quadruple your resolution, increase sampling by 6 times, and improve your accuracy with the 18-bit, 625 kS/s PCI-6281.

Add sensor and high-voltage measurement capability to your E Series device with National Instruments SCC or SCXI signal conditioning. The National Instruments PXI-6030E uses E Series technology to deliver high-performance, reliable data acquisition capabilities to meet a wide range of application requirements. You get 100 kS/s sampling and 16-bit resolution with 16 single-ended analog inputs. Depending on your type of hard drive, the NI PXI-6030E can stream to disk at rates up to 100 kS/s.

Using NI hardware and driver software options, you have flexible OS, application development environment, and application software choices. Complete your DAQ system with NI signal conditioning to measure virtually any type of sensor and voltage.

NI PCI-6030E Complete Package

Each NI PCI-6030E requires:

1 Connector Block 1 Cable NI PCI-6030E Software

Roll over icons above to learn why you need each item in the package.

NI PCI-6030E and Accessories

Hardware Subtotal: $ 3,217
NI PCI-6030E - 777384-01 Qty $ 2,799 each
Connector Block - Screw Terminal
SCB-68 - 776844-01
Qty $ 299 each
Warning : You removed a required accessory. If you would like to reselect it or see other options, click Select Accessories. [Close]
Warning : You removed a required accessory. If you would like to reselect it or see other options, click Change Accessories. [Close]
Cable - Shielded
SH68-68-EP (2m) - 184749-02
Qty $ 119 each
Warning : You removed a required accessory. If you would like to reselect it or see other options, click Select Accessories. [Close]
Warning : You removed a required accessory. If you would like to reselect it or see other options, click Change Accessories. [Close]
Change Accessories
Learn about all compatible accessories and get recommendations based on your application needs.

Software

Software Subtotal: $ 0
NI LabVIEW Full Development System for Windows (English) - 776670-35 Qty $ 2,599 each
Note : You should only purchase this device without software if you already own compatible application software. View Compatible Application Software | Compare to LabVIEW SignalExpress Limited Edition [Close]
Note : This software is required to use LabVIEW Application Builder for Windows. You should purchase LabVIEW Application Builder for Windows without a LabVIEW Development System only if you already own LabVIEW Base or Full for Windows version 8.6.1 or later. Upgrade Your Development System Now [Close]
LabVIEW Application Builder for Windows (English) - 776675-35 Qty $ 999 each
Note : NI recommends this software for use with your hardware to maximize your productivity. [Close]
Change Software
Learn about other compatible software, OS, and language options.
Package Price: $ 3,217
  Add to Cart >>
Guarantee your price for 30 days (learn more)Instant Quote
 

You have selected United States as the country where you will use this product(s) (change)

Specifications Documents


Specifications Summary

General
Product Name PCI-6030E
Product Family Multifunction Data Acquisition
Form Factor PCI
Operating System/Target Windows , Real-Time , Linux , Mac OS
LabVIEW RT Support Yes
DAQ Product Family E Series
RoHS Compliant No
Analog Input
Channels 16 , 8
Single-Ended Channels 16
Differential Channels 8
Resolution 16 bits
Sample Rate 100 kS/s
Max Voltage 10.0 V
Maximum Voltage Range 10.0 , -10.0 V
Maximum Voltage Range Accuracy 1.147 mV
Minimum Voltage Range 100 V , 0 nV
Minimum Voltage Range Accuracy 59 µV
Number of Ranges 14
Simultaneous Sampling No
On-Board Memory 512 B
Analog Output
Channels 2
Resolution 16 bits
Max Voltage 10.0 V
Maximum Voltage Range 10.0 , -10.0 V
Maximum Voltage Range Accuracy 1.430 mV
Minimum Voltage Range 10.0 , 0.0 V
Minimum Voltage Range Accuracy 1.201 mV
Update Rate 100 kS/s
Current Drive Single 5 mA
Digital I/O
Bidirectional Channels 8
Input-Only Cannels 0
Output-Only Channels 0
Number of Channels 8 , 0 , 0
Timing Software
Logic Levels TTL
Input Current Flow Sinking , Sourcing
Output Current Flow Sinking , Sourcing
Programmable Input Filters No
Supports Programmable Power-Up States? No
Current Drive Single 24 mA
Current Drive All 192 mA
Watchdog Timer No
Supports Handshaking I/O? No
Supports Pattern I/O? No
Maximum Input Range 5.0 , 0.0 V
Maximum Output Range 5.0 , 0.0 V
Counter/Timers
Counters 2
Number of DMA Channels 1
Buffered Operations Yes
Debouncing/Glitch Removal No
GPS Synchronization No
Maximum Range 5.0 , 0.0 V
Max Source Frequency 20 MHz
Minimum Input Pulse Width 10 ns
Pulse Generation Yes
Resolution 24 bits
Timebase Stability 100.0 ppm
Logic Levels TTL
Physical Specifications
Length 17.500 cm
Width 10.600 cm
I/O Connector 68-pin male SCSI-II type

Extended Warranties

National Instruments designs and manufactures all products to minimize failures, however unexpected failures can still occur. Extended warranties provide a fixed economical price at the time of system purchase, covering any repair costs for up to three years. In addition, they offer the following benefits:

  • Significant cost savings compared to individual repair incidents
  • Fault location, diagnostics, and repair by NI any time the system product fails
  • All parts and labor costs covered as well as any adjustments needed to restore the hardware to manufacturing specifications

For more information about your warranty options:

Calibration

NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. NI provides manual calibration procedures, services to recalibrate your products, and automated calibration software to calibrate many NI measurement products.

Training

NI training is the fastest, most certain route to productivity with NI tools and successful application development.

Repair Services

Return your registered product under warranty at no additional labor and parts cost. NI offers fault location, diagnostics, and repair any time the system fails as well as any adjustments needed to restore the hardware to manufacturing specifications.

Technical Support

ni.com/support