SCC-A10 Voltage Attenuator Module User Guide and Specifications
The SCC-A10 voltage attenuator module accepts up to two voltage sources of 60 V maximum amplitude and attenuates each voltage by a factor of 10. A differential instrumentation amplifier buffers each input signal. The SCC-A10 contains circuitry capable of protecting E/M Series DAQ devices for input
Edition Date:
December-2005
URL: http://digital.ni.com/manuals.nsf/websearch/91DE4E5D395AD2C4862570C90057CC85
|
|
SCC-AI Series Isolated Analog Input Modules User Guide and Specifications
The SCC-AI Series isolated analog input modules can extract a relatively low-amplitude input signal from a high-common-mode voltage so the E/M Series DAQ device can measure the input signal. They also can amplify and filter the input signal, resulting in higher measurement resolution and accuracy.
Edition Date:
December-2005
URL: http://digital.ni.com/manuals.nsf/websearch/EC8954C20F3FD057862570C900577D66
|
|
SCC-AO10 Isolated Analog Output Module User Guide and Specifications
The SCC-AO10 is an isolated voltage output module with an output range of 10 V. The output voltage level is controlled by the DAC output of an E/M Series DAQ device. You can increase the output voltage level to 20 V by connecting two SCC-AO10 modules in series.
Edition Date:
December-2005
URL: http://digital.ni.com/manuals.nsf/websearch/3C8768ADF63D98A6862570C900585591
|
|
SCC-CO20 Isolated Current Output Module User Guide and Specifications
The SCC-CO20 is an isolated current output module that outputs up to 20 mA. The output current level is proportional to the voltage applied to the module by an analog output channel of an E/M Series DAQ device.
Edition Date:
December-2005
URL: http://digital.ni.com/manuals.nsf/websearch/5053360E687A369B862570C9005823AF
|
|
NI PXI-4220 Calibration Procedure
This document contains the information and instructions needed to calibrate the NI PXI-4220.
Edition Date:
November-2005
URL: http://digital.ni.com/manuals.nsf/websearch/E22C1055701C3E0B862570B30056497C
|
|
SCC Quick Start Guide
This document explains how to install, configure, and set up National Instruments SCC modules. This document assumes you have already installed, configured, and tested the data acquisition (DAQ) device you will connect to the SC-2345/2350 carrier.
Edition Date:
September-2005
URL: http://digital.ni.com/manuals.nsf/websearch/5587D12C545D7ED9862570600070E302
|
|
SCC-CTR01 Isolated Counter/Timer I/O Module User Guide and Specifications
The SCC-CTR01 is a two input and one output isolation module for general-purpose counter/timers on DAQ devices.
Edition Date:
September-2005
URL: http://digital.ni.com/manuals.nsf/websearch/AAFC29EDEC595FF0862570690075F34C
|
|
SCXI-1520 User Manual and Specifications
The SCXI-1520 module is an eight-channel module for interfacing to strain-gauge bridges and other Wheatstone-bridge based sensors. You can configure all settings on a per channel basis in software.
Edition Date:
September-2005
URL: http://digital.ni.com/manuals.nsf/websearch/74F442BE4AFE68EE8625707E006AE9D6
|
|
SCXI-1600 Calibration Procedure
This document contains information about calibrating the SCXI-1600 module. This document does not discuss programming techniques or compiler configuration.
Edition Date:
July-2005
URL: http://digital.ni.com/manuals.nsf/websearch/584EBB1B4F2957DB86257020006255BD
|
|
TB-2725 Terminal Block Installation Guide
This guide describes how to install and use the TB-2725 isothermal terminal block with the PXI-4224 modules. The TB-2725 has 16 screw terminals for easy connection of up to eight pairs of input signals, and one SMB connector for external triggering.
Edition Date:
July-2005
URL: http://digital.ni.com/manuals.nsf/websearch/57FF679C50F629B486257031004B9FB9
|