NI PXI-4224 User Manual and Specifications
The NI PXI-4224 is an 8-channel isolated analog input device with a ±10 V input range. It allows isolated analog measurements directly on the PXI platform. Edition Date: August-2006 URL: http://digital.ni.com/manuals.nsf/websearch/10203FA34D12A5FB862571BD00561D7C

SCC-68 User Guide and Specifications
The SCC-68 is an I/O connector block for easy signal connection to a National Instruments M Series or E Series data acquisition (DAQ) device. This manual describes the SCC-68 and explains how to connect and use the connector block with National Instruments M Series or E Series DAQ devices. Edition Date: August-2006 URL: http://digital.ni.com/manuals.nsf/websearch/6ECC13E530315D21862571C3004FF365

SC-2345/2350 Carrier User Manual and Specifications
This document describes how to install and configure the SC-2345/2350 carrier. The SC-2345/2350 carrier transfers signals to and from 68-pin E/M Series data acquisition (DAQ) devices, referred to as the DAQ device in this manual. When used with SCC Series modules and a shielded 68-pin cable, the Edition Date: July-2006 URL: http://digital.ni.com/manuals.nsf/websearch/09FC2D464C3C38A1862571850066A88D

SCC-RTD01 Resistance Temperature Detector User Guide and Specifications
The SCC-RTD01 resistance temperature detector (RTD) input module accepts up to two RTD input signals from 2-, 3-, or 4-wire RTDs. Each module consists of two RTD input channels, a 30 HZ Butterworth lowpass filter for each channel and a 1 mA excitation current source. Each input channel includes an Edition Date: July-2006 URL: http://digital.ni.com/manuals.nsf/websearch/6D5CE73F4F8A6F668625718500661E0E

SCC-TC Series Thermocouple Input Modules User Guide and Specifications
The SCC-TC Series thermocouple input modules, SCC-TC01 and SCC-TC02, accept input signals from B-, E-, J-, K-, N-, R-, S-, and T-type thermocouples. Each module contains thermistor circuitry powered by 2.5 V, to compensate for cold-junction effects and can detect open thermocouple circuits. Each Edition Date: July-2006 URL: http://digital.ni.com/manuals.nsf/websearch/7FAF6A7D786879B38625718500657322

SCC-RLY01 Relay Module User Guide and Specifications
The SCC-RLY01 contains one single-pole double-throw (SPDT) nonlatching relay capable of switching 5 A at 30 VDC or 250 VAC when using an SCC-68. Any single E/M Series DAQ device digital input/output (P0.) line 0 to 7 can control the SCC-RLY01. Edition Date: May-2006 URL: http://digital.ni.com/manuals.nsf/websearch/1BECC1FA3A47A22D8625714F004E15A3

SCXI Chassis User Manual and Specifications
This manual describes the electrical and mechanical aspects of the SCXI-1000, SCXI-1000DC, and SCXI-1001 chassis and contains information concerning their operation. The SCXI chassis supply power to and contain control circuitry for the SCXI series of modules. The SCXI-1000 and SCXI-1000DC hold up Edition Date: April-2006 URL: http://digital.ni.com/manuals.nsf/websearch/6B35ECF27AA9216D8625712D00520A54

SCXI-1102/B/C User Manual and Specifications
The SCXI-1102/B/C modules are for signal conditioning of thermocouples, low-bandwidth volt and millivolt sources, 4 to 20 mA current sources, and 0 to 20 mA process-current sources. The SCXI-1102/B/C has 32 differential analog input channels and one cold-junction sensor channel. Each channel also Edition Date: April-2006 URL: http://digital.ni.com/manuals.nsf/websearch/2CDD38710DA595BB86257150006A6285

SCXI-1581 User Manual and Specifications
The SCXI-1581 module provides 32 channels of 100 uA current excitation. You can use the SCXI-1581 in any application that requires 100 uA fixed current excitation. Edition Date: April-2006 URL: http://digital.ni.com/manuals.nsf/websearch/995656D2993AFE8D86257145004CEF6C

SCXI-1521/B User Manual and Specifications
The SCXI-1521 and SCXI-1521B modules are 24-channel modules for interfacing to quarter-bridge strain gauges and are configured using Measurement & Automation Explorer (MAX) or through NI-DAQmx property nodes. The SCXI-1521 has 350 ohm completion resistors while the SCXI-1521B has 120 ohm completion Edition Date: March-2006 URL: http://digital.ni.com/manuals.nsf/websearch/BB8D5A5D0F9F2C2D8625712C005BBA83