Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: CompactDAQ [remove] ,
41-50 of 173
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (3)
LabVIEW Modules (7)
Calibration Executive (1)
Driver Software (23)
LabVIEW Signal Express (7)
LabVIEW Toolkits (1)
Utility Software (3)
Hardware
Backplanes (32)
Analog Input Modules (94)
Analog Output Modules (18)
Digital Input Modules (18)
Digital Output Modules (22)
Question Type
Bug Fix/ Error Message/ Error Code (20)
FAQ (51)
Install/Config (28)
Programming (21)
Specifications/ Documentation (40)
Unexpected Behavior/ Bad Reading (13)
Document Languages
English (82)
Spanish (11)
French (4)
Japanese (17)
Chinese (Simplified) (31)
Chinese (Traditional) (10)
Korean (18)

Sort by:
41-50 of 173
|
¿Cuáles son los Requisitos de CPU para Utilizar mi Tarjeta de Serie M? He tratado de buscar en la Web pero no he encontrado ningún requisito de CPU para utilizar mi tarjeta de Serie M. ¿Cuáles son los requisitos de URL: http://digital.ni.com/public.nsf/allkb/D205178A4E45BF1F86257362001FC76B
Channel Names Cause Incorrect Analog Output on NI USB DAQ Devices When generating a voltage on the analog output of my USB devices (such as the USB-6008/9, cDAQ 9263) I notice that if the channels in my task have a numeric value at the end of the channel name, then I generate incorrect values. Why is this and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/061D00FB903F2F6586257361006C5505
Full Scale Current Output for the NI 9265 on Startup I have NI-DAQmx 8.6 installed and on startup my NI 9265 in a cDAQ chassis outputs full scale current (20mA). How can I fix this since the power up state of the card should be 0mA as written on the specification. URL: http://digital.ni.com/public.nsf/allkb/C86C74450F5B78518625735A0056C8C6
Why do I see Voltage Offsets in NI 9237 Acquisitions when Connecting Additional Strain Sensors? While measuring strain from a channel on the NI 9237, if an additional strain sensor is inserted into an available channel on the module it may cause other channels to see an offset. How can I correct this offset? URL: http://digital.ni.com/public.nsf/allkb/57BEE29D9B9331BE482573530078D386
为什么当连接应变片到另外一个通道时,9237原通道就会有一个电压的偏置? 当使用NI 9237的一个通道来测量应变时,如果再接一个应变片到其它的一个没有用到的通道,会导致原通道有一个电压的偏置,我应该如何校正这个电压? URL: http://digital.ni.com/public.nsf/allkb/E5285A437CDB85B18625735B00409217
How Do I Check the Status of the Relays on My NI 948x Compact DAQ Relay Module? I am using an NI 948x relay module with Compact DAQ. I know that I can use the DAQmx Write VI to open and close the relays, as explained in KnowledgeBase 44LAPTNP: What Functions Do I Use to Operate My URL: http://digital.ni.com/public.nsf/allkb/65A3DB0767ED26478625734C007271C8
Advantages of the NI 9237 Over the NI 9219 in Strain Measurements I will be using CompactDAQ or CompactRIO to acquire data from a strain gage. My two options for modules are the NI 9237 bridge module and the NI 9219 universal analog input module. What are the advantages that the 9237 has over the 9219? URL: http://digital.ni.com/public.nsf/allkb/3F3165FE0709B8B38625733E007D7C55
在应变测试中使用NI 9237比使用NI 9219的优势在哪里? 我想使用CompactDAQ 或 CompactRIO 从应变计中采集数据. 我有两个选择,一是使用NI 9237 电桥模块,一是使用NI 9219通用电压输入模块 . 使用9237比9219的优势在哪里? URL: http://digital.ni.com/public.nsf/allkb/E194B4871C42846E862573C4003A2AC2
量測 strain 時 NI 9237 相對於 NI 9219 的優勢。 我預定使用 compactDAQ 或 compactRIO 量測 Strain Gauge 的資料。NI 9237 橋接器模組與 NI 9219 通用類比輸入模組都是可以滿足我的需求的選擇。我想了解 NI 9237 優於 NI 9219 的地方。 URL: http://digital.ni.com/public.nsf/allkb/E4B6B7E2D19676D6862573490037056F
Is the NI 9481 Relay Module Normally Open or Normally Closed? I have the NI 9481 4-Channel Relay and in the specifications it says the relay type is single pole single throw (SPST), however it does not specify if the relays are normally open or normally closed. URL: http://digital.ni.com/public.nsf/allkb/8725AFE7FC1067968625733A005CA483
Sort by:
41-50 of 173
|