Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Hardware
:
CompactDAQ
/ Analog Input Modules [
remove
] ,
11-20 of
47
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Driver Software
(5)
LabVIEW Development Systems
(1)
LabVIEW Modules
(2)
LabVIEW Signal Express
(1)
LabVIEW Toolkits
(1)
Utility Software
(2)
Hardware
NI 9201
(3)
NI 9203
(1)
NI 9205
(14)
NI 9205 D-Sub
(1)
NI 9206
(6)
NI 9211
(9)
NI 9215
(5)
NI 9217
(5)
NI 9219
(4)
NI 9221
(3)
NI 9233
(11)
NI 9237
(14)
Question Type
Bug Fix/ Error Message/ Error Code
(2)
FAQ
(17)
Install/Config
(9)
Programming
(7)
Specifications/ Documentation
(6)
Unexpected Behavior/ Bad Reading
(6)
Document Languages
English
(23)
Spanish
(1)
French
(2)
Japanese
(5)
Chinese (Simplified)
(9)
Chinese (Traditional)
(2)
Korean
(5)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
47
Previous
|
Next
cRIOでNI 9219を熱電対と使う場合のCJCチャンネル(FPGA I/Oノード)の作り方
cRIOでNI 9219を熱電対と使おうと考えています。プロジェクトの中のFPGAターゲットでCモジュールの追加でNI 9219を追加しました。FPGA I/OノードとしてCJCチャンネルを作ろうとしましたが、リストに表示されません。 どのようにしたら、CJCチャンネルをFPGA
URL:
http://digital.ni.com/public.nsf/allkb/D99A5902053E0DAE8625731500129D78
NI-9219をCompact DAQで使用する場合のサンプリングレートに関して
Compact DAQでNI-9219により測定を行うと、設定したサンプリングレートでデータは読み取れるのですが、同じデータが繰り返し集録されてしまいます。データの更新頻度を上げるには、どのようにすいればよいでしょうか
URL:
http://digital.ni.com/public.nsf/allkb/3ED773B7C63AB85886257314000C348A
How to Set the Sampling Rate of the NI-9217/9219
When I try to take measurements with the NI-9217 or NI-9219 module , I see many repeated samples. In effect, I only receive new samples at a fraction of the rate that I expect. How can I control the sampling rate of the module?
URL:
http://digital.ni.com/public.nsf/allkb/1015F4182FB8A805862572D1006B4CC1
Incorrect Initial Sample with NI 9211, NI 9217, or NI 9219 in NI CompactDAQ
When I perform a hardware-timed acquisition with an NI 9211, NI 9217, or NI 9219 in NI CompactDAQ, the first sample that I read is old/stale. The rest of the data I acquire looks fine, but the first sample is not what I expect.
URL:
http://digital.ni.com/public.nsf/allkb/EC6B7C1528D610CC862572C70063366D
The NI 9217 and NI 9219 2-Wire RTD Support
The Operating Instructions for the NI 9217 and NI 9219 both explain how to connect and measure from a 4-Wire RTD and 3-Wire RTD. Do these modules also support 2-Wire RTD's?
URL:
http://digital.ni.com/public.nsf/allkb/09E99F60C481D613862572C300637341
如何增加FieldPoint或者cRIO RTD模块的范围?
我有一个RTD,其电阻值超出了我的RTD模拟输入模块指定的测量范围。可否扩展最大阻值以使我的RTD能够测量?
URL:
http://digital.ni.com/public.nsf/allkb/3437EF0534231DEC482572BA0012011F
NI 9945 or NI 9944 with an NI 9237 Connection Guide
How do I connect my strain gauge to a NI 9944 or NI 9945 and NI 9237?
URL:
http://digital.ni.com/public.nsf/allkb/F47EFDB8B1992282862572AD007CE9C3
NI 9945とNI 9237の配線ガイド
ひずみゲージをNI 9944/5またはNI 9237にどのように配線するば良いですか?
URL:
http://digital.ni.com/public.nsf/allkb/26E7E95DC77422CA8625734F0030B544
Error -50150 when using cDAQ 9205 with Analog Reference Trigger
I have a cDAQ chassis and would like to use the 9205 to set up an analog reference trigger for the rest of the modules in the chassis. I am able to set up a task in the Measurement and Automation Explorer (MAX) for an analog reference trigger on channel 0 of the 9205. However, once I add
URL:
http://digital.ni.com/public.nsf/allkb/21017DE39A3F17F28625727C0081FA99
Using the Digital Output and PFI Lines of the 9205/6 with Compact DAQ
I have purchased the 9205/6 analog input module to use with a cDAQ chassis, and I noticed a DO and PFI line on the pinout. I noticed I can access the PFI line to use as a trigger, but I can't access either of these lines in my digital output task. How do I use them?
URL:
http://digital.ni.com/public.nsf/allkb/51DD3F0206860ABC8625724B007364C9
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
47
Previous
|
Next
Search KnowledgeBase Documents: