Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Hardware
:
CompactDAQ
/ Analog Input Modules [
remove
] ,
1-10 of
82
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Driver Software
(12)
LabVIEW Development Systems
(1)
LabVIEW Modules
(5)
LabVIEW Signal Express
(3)
LabVIEW Toolkits
(1)
Utility Software
(3)
Hardware
NI 9201
(5)
NI 9203
(5)
NI 9205
(18)
NI 9205 D-Sub
(4)
NI 9206
(10)
NI 9211
(13)
NI 9215
(10)
NI 9217
(6)
NI 9219
(9)
NI 9221
(6)
NI 9233
(19)
NI 9234
(1)
NI 9237
(37)
More...
NI 9239
(3)
Question Type
Bug Fix/ Error Message/ Error Code
(4)
FAQ
(25)
Install/Config
(13)
Programming
(12)
Specifications/ Documentation
(16)
Unexpected Behavior/ Bad Reading
(12)
Document Languages
English
(35)
Spanish
(2)
French
(3)
Japanese
(9)
Chinese (Simplified)
(18)
Chinese (Traditional)
(7)
Korean
(8)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
82
Next
NI 9219 Convert FXP to Thermocouple VI
I am using NI-RIO 2.4 with fixed point I/O and an NI 9219 in a CompactRIO. How can I convert the FXP channel value in the real-time controller or host PC to temperature units, accounting for the CJC value?
URL:
http://digital.ni.com/public.nsf/allkb/22C1D4F68DD27B6286257434005EA8F7
Current vs. Voltage Characteristics for C-Series Modules with Current Limiting Architectures
What input impedance should I expect when using a C-Series module with a current limiting architecture (9421, 9422 and 9423)?
URL:
http://digital.ni.com/public.nsf/allkb/7C8EE3C395478645862573FC00783B08
How Do I Acquire Data from More than One CompactDAQ Module in LabVIEW SignalExpress?
I need to acquire data from multiple modules in my cDAQ-9172 chassis using LabVIEW SignalExpress. How do I do accomplish this?
URL:
http://digital.ni.com/public.nsf/allkb/7F890A8413C0544A862573F4006D4E63
Does the CompactRIO 9215 Module Have Anti-Alias Filters?
We recently purchased several cRIO NI 9215 modules together with a cRIO NI 9233 module. I was looking for information on the anti-alias filters and I found that the 9215 does not have anti-alias filter and the 9233 does. Why does the cRIO-9215 module not have anti-alias filters? Which
URL:
http://digital.ni.com/public.nsf/allkb/2C4C52B37819F838862573E20055F037
How do I configure the Input Range of the NI 9237?
The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get error -200077: "Requested value is
URL:
http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
How to Wire the Shield Pins of My 994x Terminal Blocks
I see the shield terminal on my 994x terminal block but I don’t know how to use it.
URL:
http://digital.ni.com/public.nsf/allkb/E14E3FC42DD02FFE862573D30005240E
How Do I Select Configurations and Resistances of Strain Gauges in My FPGA VI for an NI 9237?
When using an NI 9237 module in an FPGA target, I don’t see a way to specify the resistance of my strain gauges or how to configure the module for quarter bridge measurement.
URL:
http://digital.ni.com/public.nsf/allkb/4E06A09A826895D98625738D006305FF
在我的FPGA VI中,如何为NI 9237进行应变计的配置和选择电阻?
当在FPGA设备中使用NI 9237模块时, 我找不到如何指定应变计的电阻,也不知道如何配置模块用于 1/4 桥测量.
URL:
http://digital.ni.com/public.nsf/allkb/0D58BB53134195AB862573C4003AFD05
How Do I Detect an Open Thermocouple Using the NI-9211?
I have read in the user manual for the NI-9211 that the module can detect open thermocouples. How do I program my application to work with this functionality?
URL:
http://digital.ni.com/public.nsf/allkb/67E93D764EC9C38086257387004EADF6
使用NI-9211時要如何偵測開路狀態的Thermocouple?
我從NI-9211的使用手冊上看到這個模組可以偵測開路狀態的thermocouples。要如何在程式中加入這個功能呢?
URL:
http://digital.ni.com/public.nsf/allkb/3A539DD864BF54F1862573F3001B6097
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
82
Next
Search KnowledgeBase Documents: