Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: CompactDAQ [remove] ,
1-10 of 152
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (1)
Driver Software (16)
LabVIEW Development Systems (1)
LabVIEW Modules (5)
LabVIEW Signal Express (7)
LabVIEW Toolkits (1)
Utility Software (3)
Hardware
Backplanes (31)
Analog Input Modules (82)
Analog Output Modules (15)
Digital Input Modules (17)
Digital Output Modules (22)
Question Type
Bug Fix/ Error Message/ Error Code (17)
FAQ (44)
Install/Config (27)
Programming (15)
Specifications/ Documentation (36)
Unexpected Behavior/ Bad Reading (13)
Document Languages
English (68)
Spanish (8)
French (4)
Japanese (16)
Chinese (Simplified) (29)
Chinese (Traditional) (9)
Korean (18)

Sort by:
1-10 of 152
NI 9219 Convert FXP to Thermocouple VI I am using NI-RIO 2.4 with fixed point I/O and an NI 9219 in a CompactRIO. How can I convert the FXP channel value in the real-time controller or host PC to temperature units, accounting for the CJC value? URL: http://digital.ni.com/public.nsf/allkb/22C1D4F68DD27B6286257434005EA8F7
Letter of Volatility for C-Series Modules I need official confirmation that sensitive data passing through National Instruments C-Series modules will be erased when the device loses power. URL: http://digital.ni.com/public.nsf/allkb/7A0C5C240BE55B0F862574120001838E
Letter of Volatility for the CompactDAQ 9172 I need official confirmation that sensitive data passing through National Instruments CompactDAQ-9172 chassis will be erased when the device loses power. URL: http://digital.ni.com/public.nsf/allkb/1BDCFC7B8C53FCFC86257411005D02C8
Current vs. Voltage Characteristics for C-Series Modules with Current Limiting Architectures What input impedance should I expect when using a C-Series module with a current limiting architecture (9421, 9422 and 9423)? URL: http://digital.ni.com/public.nsf/allkb/7C8EE3C395478645862573FC00783B08
How Do I Acquire Data from More than One CompactDAQ Module in LabVIEW SignalExpress? I need to acquire data from multiple modules in my cDAQ-9172 chassis using LabVIEW SignalExpress. How do I do accomplish this? URL: http://digital.ni.com/public.nsf/allkb/7F890A8413C0544A862573F4006D4E63
Error -200016 with NI USB-9263 I am running my NI USB-9263 at the maximum rate on all channels with the regeneration mode set to Do Not Allow Regeneration and writing less than 5000 points per write. I receive the error message URL: http://digital.ni.com/public.nsf/allkb/7DEB112180E3DA0E862573F3006A6DF7
Determining the Maximum Current Output for the NI 9263 Module I want to ouput more than 1 mA of current with my NI 9263 cDAQ module. Can I output more than 1 mA of current if so, what is the maximum current output for the NI 9263 module? URL: http://digital.ni.com/public.nsf/allkb/52A4C4851F148B42862573E800700DE0
如何判定NI 9263模块的最大电流输出 我想使用NI 9263 cDAQ模块输出大于1mA的电流,是否能够实现?如果可以的话,NI 9263模块的允许最大输出电流是多少? URL: http://digital.ni.com/public.nsf/allkb/BCC554E4549F8D12862573FD000CAC29
Does the CompactRIO 9215 Module Have Anti-Alias Filters? We recently purchased several cRIO NI 9215 modules together with a cRIO NI 9233 module. I was looking for information on the anti-alias filters and I found that the 9215 does not have anti-alias filter and the 9233 does. Why does the cRIO-9215 module not have anti-alias filters? Which URL: http://digital.ni.com/public.nsf/allkb/2C4C52B37819F838862573E20055F037
How do I configure the Input Range of the NI 9237? The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get error -200077: "Requested value is URL: http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
Sort by:
1-10 of 152