Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: PXI/CompactPCI / Platform Modules [remove] ,
1-10 of 56
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (3)
LabVIEW Modules (1)
Hardware
PXI-6651 (15)
PXI-6652 (17)
PXI-6653 (22)
PXI-6682 (3)
PXI-8210 (2)
PXI-8212 (1)
PXI-8214 (6)
PXI-8220 (1)
PXI-8221 (4)
PXI-8231 (6)
PXI-8232 (7)
PXI-8252 (2)
Question Type
Bug Fix/ Error Message/ Error Code (2)
FAQ (3)
Install/Config (11)
Programming (15)
Specifications/ Documentation (20)
Unexpected Behavior/ Bad Reading (5)
Document Languages
English (40)
Japanese (2)
Chinese (Simplified) (6)
Chinese (Traditional) (2)
Korean (6)

Sort by:
1-10 of 56
PXI-6682 Compatibility with Real-Time Systems I installed a PXI-6682 in a PXI chassis with a Real-Time embedded controller. I followed the instructions in the user manual and placed the module in slot 2 of the PXI chassis, but the PXI-6682 does not show up in Measurement & Automation Explorer (MAX). Is the PXI-6682 supported in LabVIEW URL: http://digital.ni.com/public.nsf/allkb/B0277D3B5F5677BE862573EE0080CAD6
1588 Synchronization Drifts Away with Time when using a 10 Mbps Router with the PXI-6682 I'm doing 1588 synchronization with the PXI-6682 but I've noticed that synchronization gets worse with time (the slave continues to drift away from the master). Looking at the "offset from master" property for the slave, the value will look normal (under 100ns) most of the time, but you'll URL: http://digital.ni.com/public.nsf/allkb/06F98C12AA16ACA68625737000629003
Special Considerations for PFI0 on the PXI-6682 PFI0 seems to behave inconsistently. Sometimes I get an immediate timestamp even if my input hasn't changed. The same problem happens if I connect PFI0 to a destination, the initial state seems to be floating. Do I have a problem with PFI0? URL: http://digital.ni.com/public.nsf/allkb/25CDB06E89A649B3862573700062BE1A
Error -1074118646 When Initializing Synchronization Card I'm running a program that uses the 6653 Synchronization card, but when I run the program, it stops during the initialization VI, and sends the error -1074118646. URL: http://digital.ni.com/public.nsf/allkb/94A061471960BC0D862572F20069A410
Error 1074118646 When Initializing Synchronization Card I'm running a program that tries to use the 6653 Synchronization card, but when I run the program, it stops during the initialization VI, and throws the error 1074118646. URL: http://digital.ni.com/public.nsf/allkb/3A77E1FC11D63802862572F20069A4DF
NI的PXI板卡如何同PXI背板映射? 我有一个NI的PXI板卡。我想知道这块板卡能否驱动或者读取Star Trigger,能否使用PXI触发线,能否使用10MHz的背板时钟,或者能否使用本地总线。 URL: http://digital.ni.com/public.nsf/allkb/07F96392B16454E3482572C700324329
PXI-823x或PCI-8232(千兆以太网)模块应该使用哪种线缆? NI Home This Document is not yet Rated Rate this Document PXI-823x或PCI-8232(千兆以太网)模块应该使用哪种线缆? 硬件: GPIB>>Plug-in Controllers>>PCI-8232, GPIB>>Plug-in Controllers>>PXI-8232, Instrument Connectivity Other>>Ethernet>>PXI-8231, GPIB>>Plug-in Controllers>>PCI-8232, GPIB>>Plug-in Controllers>>PXI-8232, URL: http://digital.ni.com/public.nsf/allkb/004EFF3B9DC8187C48257227000A4F52
将客户定制的FPGA代码下载到PXI-6653的FPGA上,与原有的FPGA代码并存 我想将客户定制的FPGA代码下载到PXI-6653上,这样做会覆盖PXI-6653上原有的代码么?我想通过客户定制的FPGA代码来访问PXI-6653上不同的PFI线。 URL: http://digital.ni.com/public.nsf/allkb/2F56392A1EB7B6A44825721E002A607C
How Do National Instruments PXI Boards Map to the PXI Backplane? I have a PXI National Instruments board. I want to know if my board can drive or read the Star Trigger, the PXI Trigger Lines, the 10MHz Backplane Clock, or the Local Bus. URL: http://digital.ni.com/public.nsf/allkb/F4AD3B87DC8CD62E862571E3007042E5
Troubleshooting Tips for GigE Vision Cameras Where can I find troubleshooting tips as well as general information on GigE Vision cameras? URL: http://digital.ni.com/public.nsf/allkb/9B44E123EFBAB226862571E30066891C
Sort by:
1-10 of 56