Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: PXI/CompactPCI / Chassis [remove] ,
11-20 of 134
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (2)
LabVIEW Modules (4)
Calibration Executive (1)
Driver Software (8)
Hardware
PXI-1000 (8)
PXI-1000B (20)
PXI-1002 (5)
PXI-1002B (1)
PXI-1006 (13)
PXI-1010 (26)
PXI-1011 (16)
PXI-1020 (9)
PXI-1025 (5)
PXI-1031 (5)
PXI-1031DC (1)
PXI-1042 (14)
PXI-1042Q (5)
More... 
PXI-1044 (5)
PXI-1045 (13)
PXI-1050 (11)
PXI-1052 (11)
PXI-1056 (3)
PXIe-1062Q (9)
PXIe-1065 (3)
PXIe-1075 (3)
Question Type
Bug Fix/ Error Message/ Error Code (9)
FAQ (19)
Install/Config (20)
NI AE Process (1)
Programming (15)
Specifications/ Documentation (60)
Unexpected Behavior/ Bad Reading (10)
Document Languages
English (93)
Spanish (2)
French (1)
Japanese (11)
Chinese (Simplified) (14)
Chinese (Traditional) (5)
Korean (8)

Sort by:
11-20 of 134
|
PXIe-1065 功能介绍 PXI Express 插槽通过指定的 x4 link 直接连接至控制器槽并可提供每槽(槽 7和8)高达 1GB/s 的带宽. 由于开销,芯片优化等原因, 这些槽实际上可以 提供大约800 MB/s 上行(输入板卡执行写内存操作)带宽和400 MB/s 下行带宽. URL: http://digital.ni.com/public.nsf/allkb/A1005B27375BBE618625736600242B04
PXIe Revision B Chassis Performance • I have a URL: http://digital.ni.com/public.nsf/allkb/59EDF1406F1FCEF586257307006C1B15
Can a PXI Card Taller than 100mm Fit in a PXI Chassis? I have a PXI card that is taller than the 100mm standard height. Will my PXI card fit in a NI Chassis? URL: http://digital.ni.com/public.nsf/allkb/8F8D54D39D47BF37862572C7006B4978
Line Reguration と Load Reguration の違い PXI-1042シャーシを使っています。NI PXI-1042 Series User ManualのSpecificationsを見ると、Line Reguration と Load Reguration という項目があり、電圧の範囲が異なっています。例えば、12Vのラインは、Line Reguration では、12V±0.1%(11.88~12.12V)となっていて、 Load Reguration では、12V URL: http://digital.ni.com/public.nsf/allkb/A137252DBFA6537F862572C6002739B2
在PXI/SCXI混和机箱中不能通过SCXI背板访问模拟输出通道 我正在用一个PXI-1050混合机箱,在这个PXI系统的最右边槽位上有一块MIO板卡。我想用SCXI-1180通过SCXI背板访问这块MIO板卡上的模拟输出通道,但是在这些信号输出端我得不到任何值。 URL: http://digital.ni.com/public.nsf/allkb/00D9387748E09B2F862572C400321042
How Can I Programmatically Clear PXI Trigger Routes or Reset the Chassis? I have either routed lines programmatically in LabVIEW or statically in MAX. At this point it is unclear what routes currently exist, so I would like to just reset the chassis and clear all routes. How can I do that? URL: http://digital.ni.com/public.nsf/allkb/BC3A1609E4CB2D6B862572C3005A742B
NI PXI Chassis Rack Mount Kits Standard Compatibility What standard are the NI PXI chassis rack mount kits compatible with? Are they compatible with EIA compliant racks? URL: http://digital.ni.com/public.nsf/allkb/5862602AA67C444A862572C2005B7152
Cannot Access Signals such as Analog Output Through SCXI Backplane Communication in a PXI/SCXI Combination Chassis I am using a PXI-1050 combination chassis with a supported MIO card in the right-most slot of the PXI system. I am trying to access the analog output signals from the MIO board by using an SCXI-1180 to read the signals through the SCXI backplane, but I am unable to get any readings from URL: http://digital.ni.com/public.nsf/allkb/2E4B88FDAD56DDD3492572AC0078E845
システムがPXIシャーシを使った構成になっているかを知る方法 実行ファイルを配布しようと思っていますが、実行環境がPXIかそうでないかによって設定を変更する必要があります。LabVIEWの実行環境や開発環境がPXIシャーシを使った環境か、プログラムで知ることはできますか? URL: http://digital.ni.com/public.nsf/allkb/CAAB9752CAE13C5786257281001801EA
NI PXI-103x Chassis Synchronization Troubleshoot When I route synchronization signals on a NI PXI-103x I do not get the expected results. What is the problem? URL: http://digital.ni.com/public.nsf/allkb/2E9F6CE7930B94208625727D00809E3F
Sort by:
11-20 of 134
|