Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: SCXI / Modules [remove] ,
31-40 of 426
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (7)
Calibration Executive (4)
Driver Software (44)
LabVIEW Signal Express (1)
Other NI Software (2)
Utility Software (7)
Hardware
SCXI-1100 (34)
SCXI-1102 (41)
SCXI-1102B (4)
SCXI-1102C (4)
SCXI-1104 (1)
SCXI-1104C (1)
SCXI-1112 (7)
SCXI-1120 (18)
SCXI-1120D (10)
SCXI-1121 (20)
SCXI-1122 (24)
SCXI-1124 (21)
SCXI-1125 (6)
More... 
SCXI-1126 (16)
SCXI-1127 (18)
SCXI-1128 (6)
SCXI-1129 (1)
SCXI-1140 (20)
SCXI-1141 (12)
SCXI-1142 (2)
SCXI-1143 (3)
SCXI-1160 (4)
SCXI-1161 (2)
SCXI-1162 (6)
SCXI-1162HV (7)
SCXI-1163 (10)
SCXI-1163R (2)
SCXI-1166 (2)
SCXI-1167 (1)
SCXI-1169 (1)
SCXI-1175 (1)
SCXI-1192 (1)
SCXI-1200 (36)
SCXI-1502 (1)
SCXI-1503 (2)
SCXI-1520 (72)
SCXI-1521 (4)
SCXI-1521B (4)
SCXI-1530 (9)
SCXI-1531 (9)
SCXI-1540 (8)
SCXI-1581 (8)
SCXI-1600 (28)
SCXI-2400 (4)
Question Type
Bug Fix/ Error Message/ Error Code (22)
FAQ (50)
Install/Config (52)
Programming (67)
Specifications/ Documentation (197)
Unexpected Behavior/ Bad Reading (38)
Document Languages
English (260)
Spanish (18)
French (5)
Japanese (30)
Chinese (Simplified) (46)
Chinese (Traditional) (13)
Korean (54)

Sort by:
31-40 of 426
|
哪些美国国家仪器的产品可以被用来作为电流输出? c[FP]-AIO-600 - 8通道,单端参考地,模拟输入/输出混合模块,内部更新率可达1. URL: http://digital.ni.com/public.nsf/allkb/51560496185576ED4825725D002D9E45
NI Switches and AC Wall Power Compatability Which NI Switches can be used to switch AC wall power? I tried using the SCXI 1166 to switch wall power, but it didn't operate as expected. URL: http://digital.ni.com/public.nsf/allkb/855AF9CBDAACE3018625725A00638653
NI Switch和AC壁装电源的兼容性 哪些NI Switch可以用于开关AC壁装电源? 我试着用SCXI 1166来开关壁装电源,但是没有得到预期结果。 URL: http://digital.ni.com/public.nsf/allkb/A79A0BF785A2B3668625739100347257
SCXI-1600能用在多机箱配置中吗? 我想知道如何使用SCXI-1600连接别的或者多个SCXI机箱或者数据采集卡。 URL: http://digital.ni.com/public.nsf/allkb/314C2130A17E35474825724A002476B5
为什么我的SCXI机箱不能自动检测到SCXI-1100模块? 我通过SCXI-1100模块把SCXI机箱连接到数据采集设备(DAQ),但是它没有自动检测到机箱中的任何模块。为什么呢? URL: http://digital.ni.com/public.nsf/allkb/0FE1A9E0EFEB807848257249001E1D7E
使用SCXI-1520和PXI-4220来测量全桥传感器 我有一个全桥传感器(例如压力传感器、负载单元、扭矩传感器等)。我想对传感器进行激励并且通过SCXI-1520监控响应。我如何使用传统DAQ或者DAQmx 7.x 对SCXI-1520(或PXI-4220)进行配置来创建虚拟通道、任务、或者全局通道来测量我的传感器? URL: http://digital.ni.com/public.nsf/allkb/95120F5F3CD30FFB48257249001629CF
用于热电偶测量的NI推荐硬件 NI Home This Document is not yet Rated Rate this Document 用于热电偶测量的NI推荐硬件 硬件: Multifunction DAQ (MIOE Series, Multifunction DAQ (MIOM Series, Multifunction DAQ (MIOPortable>>USB-9211A, SCXI>>Modules>>SCXI-1102, SCXI>>Terminal Blocks>>SCXI-1303, SCXI>>Modules>>SCXI-1112, SCXI>>Modules>>SCXI-1125, URL: http://digital.ni.com/public.nsf/allkb/5728F1E2C606756E4825724400233160
SCXI-1521与SCXI-1521B的应变计桥配置方法 我能否将SCXI-1521或者SCXI-1521B配置为全桥或者半桥应变计? URL: http://digital.ni.com/public.nsf/allkb/0D166E9106661A3148257243001DB287
当我使用SCXI-1327终端模块连接SCXI-1121时,我仅能访问8个通道中的4个。 我使用SCXI-1327终端模块连接SCXI-1121。在SCXI-1327中一共有8个通道可用,但当我在MAX配置一个虚拟通道时,仅允许我选择通道0-3,哪里出错了呢? URL: http://digital.ni.com/public.nsf/allkb/A990C0E97228AF5C4825722B002B17B6
电压信号合并在一起 NI Home This Document is not yet Rated Rate this Document 电压信号合并在一起 硬件: SCXI>>Modules>>SCXI-1100, SCXI>>Modules>>SCXI-1100 问题: 为什么在使用 SCXI-1100 时,我的电压信号合并在一起了? 解答: 信号合并在一起的原因是由于模块上的滤波器设置得太高了。滤波器设置可以通过模块上的跳线修改。请参考下列步骤 如果模块仍然在机箱中,关闭机箱并移除模块。 移除模块的盖板。 从 W4 中移除跳线 (4 Hz 滤波器) 并连接到 W3 (10 kHz 滤波器) 或者 W2 URL: http://digital.ni.com/public.nsf/allkb/93455DF1C82D4DDC4825721F00076CA8
Sort by:
31-40 of 426
|