Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: SCXI / Modules [remove] ,
11-20 of 416
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (4)
Driver Software (41)
LabVIEW Development Systems (7)
LabVIEW Signal Express (1)
Other NI Software (2)
Utility Software (6)
Hardware
SCXI-1100 (34)
SCXI-1102 (41)
SCXI-1102B (4)
SCXI-1102C (4)
SCXI-1104 (1)
SCXI-1104C (1)
SCXI-1112 (7)
SCXI-1120 (17)
SCXI-1120D (9)
SCXI-1121 (20)
SCXI-1122 (23)
SCXI-1124 (21)
SCXI-1125 (6)
More... 
SCXI-1126 (16)
SCXI-1127 (19)
SCXI-1128 (6)
SCXI-1129 (1)
SCXI-1140 (20)
SCXI-1141 (10)
SCXI-1142 (2)
SCXI-1143 (3)
SCXI-1160 (4)
SCXI-1161 (2)
SCXI-1162 (6)
SCXI-1162HV (7)
SCXI-1163 (10)
SCXI-1163R (2)
SCXI-1166 (2)
SCXI-1167 (1)
SCXI-1169 (1)
SCXI-1175 (1)
SCXI-1192 (1)
SCXI-1200 (36)
SCXI-1502 (1)
SCXI-1503 (1)
SCXI-1520 (68)
SCXI-1521 (4)
SCXI-1521B (4)
SCXI-1530 (9)
SCXI-1531 (9)
SCXI-1540 (8)
SCXI-1581 (8)
SCXI-1600 (27)
SCXI-2400 (4)
Question Type
Bug Fix/ Error Message/ Error Code (22)
FAQ (48)
Install/Config (52)
Programming (63)
Specifications/ Documentation (194)
Unexpected Behavior/ Bad Reading (37)
Document Languages
English (256)
Spanish (18)
French (5)
Japanese (29)
Chinese (Simplified) (41)
Chinese (Traditional) (13)
Korean (54)

Sort by:
11-20 of 416
|
What is the Frequency Response for the SCXI-1102? The manual for the SCXI-1102 lists that the lowpass filter is a two-pole filter with a 2 Hz cutoff frequency to reject 60 Hz noise. What family of filter is this? URL: http://digital.ni.com/public.nsf/allkb/3CFA60E20AC9C72586257341007F3AD4
What is the Frequency Response for the SCXI-1102B? The manual for the SCXI-1102B lists that the lowpass filter in the device is a 3 pole filter with a 200 Hz cutoff frequency. What family of filter is this? URL: http://digital.ni.com/public.nsf/allkb/A21EAC7B480EED958625732C00816637
Programmatically Obtaining Serial Number from SCXI-1127 and SCXI-1128 Modules I am using the DAQmx Device » DevSerialNum property node in LabVIEW, and returning a value of '0' for the SCXI-1127 and SCXI-1128 devices in my system. All of my other SCXI modules return proper serial numbers. Why do I recieve a '0' instead of a serial number for these two modules? URL: http://digital.ni.com/public.nsf/allkb/8B1C5C1F5EEF15AA862572C700574A50
MAX에서 시뮬레이션이 지원되지 않는 DAQ 디바이스 NI-DAQmx가 지원되는 디바이스를 가지고 있고, NI-DAQmx를 설치했습니다. MAX에서 해당 디바이스를 시뮬레이션하려고 하는데 설정 tree에서 내 시스템>>디바이스와 인터페이스>>NI-DAQmx디바이스에서 마우스 우클릭하여 새 NI-DAQmx디바이스 URL: http://digital.ni.com/public.nsf/allkb/7043425C266978A1862572E6000FEF8C
Why Can't I Simulate my DAQ Device in Measurement & Automation Explorer? My device is supported in NI-DAQmx and I have NI-DAQmx installed. I would like to simulate my National Instruments DAQ device in Measurement & Automation Explorer (MAX). When I navigate in the MAX Configuration tree to My System » Data Neighborhood » Devices and URL: http://digital.ni.com/public.nsf/allkb/4B20AD64F650D2D5862572C2005779A7
¿Por qué no Puedo Simular mi Dispositivo en Measurement & Automation Explorer? Mi dispositivo si es soportado por NI-DAQmx y lo tengo instalado en mi computadora. Quiero simular mi dispositivo en Measurement & Automation Explorer (MAX). Cuando voy a voy a My System » Data Neighborhood » Devices and Interfaces y doy clic derecho en NI-DAQmx Devices y selecciono Create New URL: http://digital.ni.com/public.nsf/allkb/E6B55E10990A5E3A862572C6006934EE
Error -17208 When Using SCXI-1104 with Calibration Executive 3.2 Error -17208 is returned when calibrating an SCXI-1104 with Calibration Executive 3.2. URL: http://digital.ni.com/public.nsf/allkb/2FC4059D33FEF318862572BB0043704C
MAX에서 SCXI-1163이 보이지 않는 이유 SCXI-1163을 샤시에 삽입한 후, SCXI 샤시 설정 대화 창에서 Auto-Detect All Modules버튼을 클릭해도, MAX가 SCXI-1163을 인식하지 못합니다. URL: http://digital.ni.com/public.nsf/allkb/EB7A7DBDCCB2EA19862572BA002AD534
Why Isn't My SCXI-1163 Detected in MAX? I have a SCXI-1163 in my SCXI chassis, but when I click the Auto-Detect All Modules button in my SCXI Chassis Configuration dialog box, MAX does not find my SCXI-1163. URL: http://digital.ni.com/public.nsf/allkb/919B8C262E74A861862572B50049CF24
Which Strain Gauge Modules Support Custom Shunt Calibration Values? National Instruments' strain gauge module 1521x has a Shunt Resistance of 100kΩ, is there anyway of changing this value? URL: http://digital.ni.com/public.nsf/allkb/6B1B3E8A2A484351862572900035F807
Sort by:
11-20 of 416
|