Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: SCXI [remove] ,
1-10 of 782
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (5)
Driver Software (64)
LabVIEW Development Systems (14)
LabVIEW Modules (1)
LabVIEW Signal Express (1)
LabWindows/CVI Development Systems (2)
Other NI Software (4)
Utility Software (10)
Hardware
Chassis (91)
Modules (410)
Terminal Blocks (100)
Custom Modules and Terminal Blocks (6)
Question Type
Bug Fix/ Error Message/ Error Code (44)
FAQ (93)
Install/Config (99)
Programming (107)
Specifications/ Documentation (371)
Unexpected Behavior/ Bad Reading (68)
Document Languages
English (476)
Spanish (27)
French (1)
Japanese (72)
Chinese (Simplified) (84)
Chinese (Traditional) (25)
Korean (97)

Sort by:
1-10 of 782
Windows Vista DAQPad/DAQCard Support I have a National Instruments DAQPad/Card that worked fine previously, but doesn't function properly in Windows Vista. Why? URL: http://digital.ni.com/public.nsf/allkb/678CCC14FEA8F8CE8625743400680F8D
Why does the Auto-Detect Fail to Recognize my SCXI-1163R? I am controlling a SCXI chassis with an M-Series DAQ device. Currently I have the chassis properly configured in MAX with the appropriate communicating device selected and it auto-detects and recognizes all modules except my SCXI 1163R. I have ensured that all the jumpers are in their URL: http://digital.ni.com/public.nsf/allkb/ED9E094B7996D4A58625743300606C56
Maximum Voltage When Using the SCXI-1180/1181 Problem: What is the maximum voltage the SCXI-1180 or SCXI-1181 can handle? Solution: The SCXI-1180/1181 User Manual, p28, has the following warning: Warning: The SCXI-1181 is not intended for use with hazardous voltages (voltages exceeding 42 Vrms). URL: http://digital.ni.com/public.nsf/allkb/5F39B709FC0AE1568625742700453B55
LFH200 Bare Wire Cables with Date Codes 3707 and 5007 Have Incorrect Pinouts On the LFH200 Bare Wire cable, Leg J2, Leg J3, Leg J6 and Leg J7 have mismatched wire color codes when compared with the pin assignment table given in the LFH200 Cable Installation Instructions. This URL: http://digital.ni.com/public.nsf/allkb/F6C3FFFAC2A65970862573E7007F822E
How do I Determine the Sampling Rate for a SCXI 1520 Module. Problem: How do I determine the sampling rate for a SCXI 1520 module? Solution: SCXI 1520 is a simultaneous sampling device that uses track-and-hold technology. The maximum convert rate for simultaneous sample and hold (SSH) circuit in the SCXI 1520 is 10 us. URL: http://digital.ni.com/public.nsf/allkb/3E99FB68FDBD4ECB862573AF007DD7CE
How Can I Test a Device that Requires Excitation in MAX? I am testing my SCXI device using test panels in Measurement & Automation Explorer (MAX) but the values aren't what I'm expecting. Is something wrong with my device? URL: http://digital.ni.com/public.nsf/allkb/C2553DEE2E3CF1BE862573A30062C1F3
PXI-SCXI组合机箱的SCXI模块没有被自动选择 在我的组合机箱中,没有一个SCXI模块被自动选择好,甚至机箱已经上电并正确连接。如果我人为选择好模块,则没有一个模块能工作。如何解决这个问题? URL: http://digital.ni.com/public.nsf/allkb/8F70A697373F966A4825739100134E26
为什么我的SCXI-1163在MAX中探测不到? 我有一个SCXI-1163在SCXI机箱中,但是当我在SCXI机箱配置对话框中点击Auto-Detect All Modules按钮时,MAX找不到SCXI-1163。 URL: http://digital.ni.com/public.nsf/allkb/646043A1CC9D701F4825739100233254
在并行模式下,哪些数字线被SCXI保留了? 我想使用DAQ板卡的数字和PFI线,而这块DAQ卡正连接到一个并行模式下的SCXI模块。在SCXI-1180穿通面板上可以做这个吗? URL: http://digital.ni.com/public.nsf/allkb/80A07DF7FE4656494825739100105D7F
如果使用SCXI-1124输出大于20MA的电流? 我使用一个SCXI-1124以及SCXI-1325接线盒。根据用户手册中的指标,SCXI-1124能够输出的电流介于0到20mA之间。有什么办法让我从这个模块输出大于20mA的电流? URL: http://digital.ni.com/public.nsf/allkb/BB6CEE5CBEDECF6248257391000B0F7B