5B Power Supply Manufacturer's Part Number and Dimensions
What is the manufacturer's part number and dimensions of the 5B external power supplies?
URL: http://digital.ni.com/public.nsf/allkb/6D8B669620DA556D86256625007C9473
|
Input Modes (RSE & NRSE) When Using 5B Input Modules
When configuring my data acquisition (DAQ) device for use with 5B input modules, which input mode should I use: differential (DIFF), nonreferenced single-ended (NRSE), or referenced single-ended (RSE)?
URL: http://digital.ni.com/public.nsf/allkb/FA40BD14018D8FBF862565FE004AAA69
|
Open Thermocouple on one 5B47 Module Causes Voltage Change on Other Channels
I am using an AT-MIO-16E-1 with a 5B backplane, six 5B47 modules (not obtained from National Instruments) , and LabVIEW. When I scan all channels above 20k Scans/s, and one of the channels become open thermocouple, I see a change of 25-30 LSBs on the other channels.
URL: http://digital.ni.com/public.nsf/allkb/E06803F7006F11D28625658700569AA5
|
What is the Small Black Component that Shipped With the 5B-32 Module?
and plugs directly into the backplane just behind the 5B-32 Module (between the module and the screw terminals). There are two different versions of this current resistor because there are two different manufacturers of the 5B product line: Analog Devices and Dataforth.
URL: http://digital.ni.com/public.nsf/allkb/47D441AB07E671018625656700703786
|
How Do I Connect a 955 Power Supply to the 5B Backplane?
Some of the 5B backplanes such as the 5B08 require an external power supply. I've purchased a power cord from an electronics store, and the cord has three wires which correspond to Live, Neutral, and Ground of an AC wall outlet. The Analog Devices 955 power supply has 6 screw terminals, labeled AC
URL: http://digital.ni.com/public.nsf/allkb/647DF2AEC860771E8625653D0072EA77
|
5B49 Documentation
Problem: Where can I find documentation for the 5B49? Solution: The 5B49 is not made by Analog Devices, but by Dataforth Corporation. Please follow the link below to download the datasheets for the module from the Dataforth website.
URL: http://digital.ni.com/public.nsf/allkb/01B72B78C708AE758625652A0056A087
|
How to Do Analog Output with an 8 Channel and 16 Channel 5B Backplanes
National Instruments sells both the 8 channel and the 16 channel version of the 5B Series backplane. How do I connect them to my data acquisition board?
URL: http://digital.ni.com/public.nsf/allkb/9158F6383D3CECBC85256441005452DD
|
Why Is the Signal from my 5B Analog Input Module Floating?
If I leave my E-series MIO board in the default configuration and read analog inputs via my 5B-series modules, I get a floating signal. Why is my 5B-series analog input signal floating? Does my board configuration affect this?
URL: http://digital.ni.com/public.nsf/allkb/BDCD2656F6A8CFA7862562B4007A0DBF
|
5B 백플레인과 아날로그 출력 모듈들을 Lab-PC 시리즈 (PC+, PC-1200)과 1200 시리즈 보드, SC-2053과 같이 어떻게 씁니까?
LAB-PC+, Lab-PC-1200 또는 a1200 시리즈 보드를 SC-2053과 16 모듈 5B 백플레인을 함께 사용할 때, 아날로그 출력 모듈은 제대로 동작하기 위해 특정한 위치에 있어야만 합니다. 어디에 설치해야 합니까?
URL: http://digital.ni.com/public.nsf/allkb/5941AA9B4D9D75E386256FBA00034E9A
|
How Do I Use the 5B Backplane and Analog Output Modules with a Lab-PC Series (PC+, PC-1200) and 1200 Series Board and a SC-2053?
When using a LAB-PC+, Lab-PC-1200, or a1200 series board with an SC-2053 and a 16 module 5B backplane, the analog output modules must be in specific positions in order to function properly. Which positions can they be in?
URL: http://digital.ni.com/public.nsf/allkb/570E3C188BFA148F862561B70065A72F
|