Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: CompactRIO / Analog Input Modules [remove] ,
21-30 of 114
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (1)
LabVIEW Modules (9)
Driver Software (21)
LabVIEW Signal Express (3)
LabVIEW Toolkits (1)
Utility Software (3)
Hardware
NI 9201 (5)
NI 9203 (5)
NI 9205 (22)
NI 9205 D-Sub (4)
NI 9206 (11)
NI 9211 (14)
NI 9215 (10)
NI 9217 (7)
NI 9219 (11)
NI 9221 (6)
NI 9233 (20)
NI 9237 (43)
NI 9239 (3)
More... 
cRIO-9220 (2)
cRIO-9231 (5)
Question Type
Bug Fix/ Error Message/ Error Code (5)
FAQ (42)
Install/Config (14)
Programming (21)
Specifications/ Documentation (20)
Unexpected Behavior/ Bad Reading (12)
Document Languages
English (51)
Spanish (6)
French (3)
Japanese (11)
Chinese (Simplified) (24)
Chinese (Traditional) (10)
Korean (9)

Sort by:
21-30 of 114
|
How Do I Configure the Input Range of the NI 9237? The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get URL: http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
How to Wire the Shield Pins of My 994x Terminal Blocks I see the shield terminal on my 994x terminal block but I don’t know how to use it. URL: http://digital.ni.com/public.nsf/allkb/E14E3FC42DD02FFE862573D30005240E
How Do I Select Configurations and Resistances of Strain Gauges in My FPGA VI for an NI 9237? When using an NI 9237 module in an FPGA target, I don’t see a way to specify the resistance of my strain gauges or how to configure the module for quarter bridge measurement. URL: http://digital.ni.com/public.nsf/allkb/4E06A09A826895D98625738D006305FF
在我的FPGA VI中,如何为NI 9237进行应变计的配置和选择电阻? 当在FPGA设备中使用NI 9237模块时, 我找不到如何指定应变计的电阻,也不知道如何配置模块用于 1/4 桥测量. URL: http://digital.ni.com/public.nsf/allkb/0D58BB53134195AB862573C4003AFD05
How Do I Detect an Open Thermocouple Using the NI-9211? I have read in the user manual for the NI-9211 that the module can detect open thermocouples. How do I program my application to work with this functionality? URL: http://digital.ni.com/public.nsf/allkb/67E93D764EC9C38086257387004EADF6
使用NI-9211時要如何偵測開路狀態的Thermocouple? 我從NI-9211的使用手冊上看到這個模組可以偵測開路狀態的thermocouples。要如何在程式中加入這個功能呢? URL: http://digital.ni.com/public.nsf/allkb/3A539DD864BF54F1862573F3001B6097
Warning 200045 When Using NI-9237 in NI cDAQ-9172 When I use my NI-9237 in a NI cDAQ-9172 chassis I receive the following warning:Warning 200045 occurredPossible Reason(s):Measurements: EEPROM of the device appears to be URL: http://digital.ni.com/public.nsf/allkb/26A60C1D0DFF711A8625738500582D03
NI 9237真实的激励电压与指定电压值不同 在用NI 9237创建Strain或者Custom Voltage with Excitation的DAQmx任务时,在任务中指定的激励电压与我在Ex+和Ex-两端之间测到的电压不一致。例如,在创建任务时,我指定的激励电压为6V。然而,我在Ex+和Ex URL: http://digital.ni.com/public.nsf/allkb/3F7E5F74EE6458AB4825736F00208909
¿Por Qué se Escuchan Mal los Archivos .WAV de los Datos Adquiridos con un Dispositivo 9233? Tengo el Sound and Vibration Toolkit 4.0 y estoy adquiriendo una señal a través de un micrófono conectado a un dispositivo 9233. Guardo los datos adquiridos a un archivo .WAV mediante el ejemplo que viene con el toolkit llamado SVXMPL_WAV Recorder (DAQmx).vi. Cuando escucho el WAV a traves de URL: http://digital.ni.com/public.nsf/allkb/12B8285B75746ACC8625736F00496550
Why do I see Voltage Offsets in NI 9237 Acquisitions when Connecting Additional Strain Sensors? While measuring strain from a channel on the NI 9237, if an additional strain sensor is inserted into an available channel on the module it may cause other channels to see an offset. How can I correct this offset? URL: http://digital.ni.com/public.nsf/allkb/57BEE29D9B9331BE482573530078D386
Sort by: