Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Hardware
:
CompactRIO
/ Analog Input Modules [
remove
] ,
1-10 of
94
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Driver Software
(13)
LabVIEW Modules
(6)
LabVIEW Signal Express
(3)
LabVIEW Toolkits
(1)
Utility Software
(3)
Hardware
NI 9201
(5)
NI 9203
(5)
NI 9205
(19)
NI 9205 D-Sub
(4)
NI 9206
(10)
NI 9211
(13)
NI 9215
(10)
NI 9217
(6)
NI 9221
(6)
NI 9233
(19)
NI 9234
(1)
NI 9237
(37)
NI 9239
(3)
More...
cRIO-9220
(2)
cRIO-9231
(4)
Question Type
Bug Fix/ Error Message/ Error Code
(4)
FAQ
(33)
Install/Config
(13)
Programming
(15)
Specifications/ Documentation
(17)
Unexpected Behavior/ Bad Reading
(12)
Document Languages
English
(42)
Spanish
(3)
French
(3)
Japanese
(8)
Chinese (Simplified)
(22)
Chinese (Traditional)
(7)
Korean
(9)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
94
Next
Programmatically Setting the NI 9205 Voltage Range
I want to be able to programmatically set the voltage range on each of my analog inputs on the NI 9205 independently. How do I set these ranges?
URL:
http://digital.ni.com/public.nsf/allkb/32C533AF9AFAF3B38625746E004A510F
Switching Between Calibrated Fixed-Point and Raw Integer Modes for CompactRIO I/O
How can I select either calibrated fixed-point or raw integer data types for the I/O nodes of my C-Series module?
URL:
http://digital.ni.com/public.nsf/allkb/F4ECE2EDDA91E5A386257441005D897E
What Units Are Returned from C-Series Analog Modules when using Fixed-Point Data?
I am using Fixed-Point Data in my FPGA project for my C-series analog modules. What units will be returned with this data?
URL:
http://digital.ni.com/public.nsf/allkb/C18C172029D187CA8625741600664D89
¿Cuáles son las Unidades de los Valores Provenientes de Mi Módulo de la Serie C utilizado en un cRIO?
No entiendo el valor de las medidas que estoy leyendo de mi Módulo de la Serie C.
URL:
http://digital.ni.com/public.nsf/allkb/59F2CF49FB4A5BC28625743A00562AB6
Current vs. Voltage Characteristics for C-Series Modules with Current Limiting Architectures
What input impedance should I expect when using a C-Series module with a current limiting architecture (9421, 9422 and 9423)?
URL:
http://digital.ni.com/public.nsf/allkb/7C8EE3C395478645862573FC00783B08
How Do I Acquire Data from More than One CompactDAQ Module in LabVIEW SignalExpress?
I need to acquire data from multiple modules in my cDAQ-9172 chassis using LabVIEW SignalExpress. How do I do accomplish this?
URL:
http://digital.ni.com/public.nsf/allkb/7F890A8413C0544A862573F4006D4E63
Does the CompactRIO 9215 Module Have Anti-Alias Filters?
We recently purchased several cRIO NI 9215 modules together with a cRIO NI 9233 module. I was looking for information on the anti-alias filters and I found that the 9215 does not have anti-alias filter and the 9233 does. Why does the cRIO-9215 module not have anti-alias filters? Which
URL:
http://digital.ni.com/public.nsf/allkb/2C4C52B37819F838862573E20055F037
Why Do I See Large Binary Values Coming From Coming from My Analog FPGA Reading
I am seeing raw binary data that is outside of the range of my analog device.
URL:
http://digital.ni.com/public.nsf/allkb/7829D061AB7EF7F1862573E100702A2C
Moving CompactRIO VIs with Uncalibrated Data to FPGA Targets with Calibrated Data
In versions of NI-RIO prior to 2.4, C Series Modules only return binary (uncalibrated) data, which requires the host VI to apply calibration coefficients and convert the data to engineering units in software. After installing NI-RIO 2.4 or later, the default behavior for AI/AO modules is to
URL:
http://digital.ni.com/public.nsf/allkb/254BBC14267D2972862573E000824912
How do I configure the Input Range of the NI 9237?
The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get error -200077: "Requested value is
URL:
http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
94
Next
Search KnowledgeBase Documents: