使用SCXI-1520和PXI-4220来测量全桥传感器
我有一个全桥传感器(例如压力传感器、负载单元、扭矩传感器等)。我想对传感器进行激励并且通过SCXI-1520监控响应。我如何使用传统DAQ或者DAQmx 7.x 对SCXI-1520(或PXI-4220)进行配置来创建虚拟通道、任务、或者全局通道来测量我的传感器?
URL:
http://digital.ni.com/public.nsf/allkb/95120F5F3CD30FFB48257249001629CF
PXI-4224 Does Not Meet Bandwidth Specifications
The PXI-4224 manual states that the filter has a cutoff frequency of 30KHz. Why can't I get correct measurements above 15KHz?
URL:
http://digital.ni.com/public.nsf/allkb/434B9832F768A2B2862571D5007AA1B9
Comment configurer un trigger numérique dans un châssis CompactDAQ ?
J’ai un module d’entrée analogique dans mon châssis NI cDAQ-9172. J’essaye d’utiliser le trigger numérique mais je ne peux pas sélectionner de lignes PFI. Comment résoudre ce problème ?
URL:
http://digital.ni.com/public.nsf/allkb/29B54436333C5D2A862571990053EEE3
How to do a Null-Offset Calibration for Full-Bridge Absolute Transducers (SCXI-1520 / PXI-4220) with the DAQ Assistant?
The DAQ Assistant does not provide a way to do any calibration for Full-Bridge Absolute Transducers that are not strain gauges (for example load cells) for a NI-DAQmx Tasks / Global Channels created in MAX.If I use the example VI located in the example finder ( Browse According to
URL:
http://digital.ni.com/public.nsf/allkb/3593FEAB432C2B0C8625713E0059E5E9
Measuring a Full-Bridge Absolute Transducer with the SCXI-1520 or PXI-4220
I have a full-bridge transducer (such as a pressure transducer, load cell, torque transducer, etc). I want to excite the transducer and monitor the response with an SCXI-1520. How do I use Traditional NI-DAQ or NI-DAQmx 7.x to configure the SCXI-1520 (or PXI-4220) and create virtual
URL:
http://digital.ni.com/public.nsf/allkb/FD9F22608FDC939A86256B5A0075705D
SCXI-1520 혹은 PXI-4220를 이용하여 완전 브리지 절대 트랜스듀서(Full-Bridge Absolute Transducer) 측정하기
저는 완전-브리지(full-bridge) 트랜스듀서(압력 트랜스듀서, 로드셀, 토크 트랜스듀서 등)를 가지고 있습니다. SCXI-1520으로 트랜스듀서에 전원을 인가하고 응답을 모니터링하려고 합니다. SCXI-1520(혹은 PXI-4220)을 사용하려면 Traditional NI-DAQ 혹은 NI-DAQmx 7.x를 어떻게
URL:
http://digital.ni.com/public.nsf/allkb/74DCBA931B1EA477862572810018C6AF