Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: Modular Instruments [remove] ,
11-20 of 649
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (6)
Driver Software (95)
LabVIEW Development Systems (37)
LabVIEW Modules (4)
LabVIEW Toolkits (5)
LabWindows/CVI Development Systems (1)
Measurement Studio (4)
Other NI Software (3)
Hardware
Digital Multimeters (DMM) (108)
Digital Transmission Analyzers (4)
Dynamic Signal Acquisition and Analysis (DSA) (232)
High-Speed Digitizers (Scopes) (148)
High-Precision DAQ (Dataloggers) (60)
RF Measurement Devices (77)
Power Supplies (14)
Question Type
Bug Fix/ Error Message/ Error Code (81)
FAQ (117)
Install/Config (35)
Programming (163)
Specifications/ Documentation (208)
Unexpected Behavior/ Bad Reading (45)
Document Languages
English (338)
Spanish (27)
French (5)
Japanese (47)
Chinese (Simplified) (110)
Chinese (Traditional) (46)
Korean (76)

Sort by:
11-20 of 649
|
Calibration Executive Report Shows Failure for NI 4060 when Software Indicates Passing When I run a "verify only" on a 4060 it will show as a green PASS but in the report, it does not meet the "as Left" data (which are 24hr specifications) and thus will show FAILED. URL: http://digital.ni.com/public.nsf/allkb/F099D251EAFA73DE862573AE000A6F1C
Ventajas de la Memoria Integrada en los Digitalizadores. En las nuevas tarjetas digitalizadoras PCIe y PXIe que usan la tecnología “PCI Express”, la cantidad de datos que pueden ser comunicados entre la tarjeta y la PC así como el reducido tiempo de latencia de la transmisión, permiten unas velocidades de transferencia entre la tarjeta y la URL: http://digital.ni.com/public.nsf/allkb/612841BC4AB4BA9C862573AD006CEE70
¿Cuál es el la Resolución del Retraso (delay) del Disparo (trigger) en un NI 5112? En la documentación del PXI-5112, encontramos que el retraso del disparo (trigger delay), se puede configurar entre 40 nano segundos y 171.85 segundos. ¿Cuál es entonces la resolución de esta demora de disparo?. Por ejemplo, podría yo especificar una demora de disparo de 41, 40.1 ó URL: http://digital.ni.com/public.nsf/allkb/4601345517DDD953862573AC006C1E23
¿Cual es la Relación entre Ancho de Banda y Tiempo de Subida? Me gustaría digitalizar una onda cuadrada con tiempo de subida específico pero no estoy seguro cual es el ancho de banda recomendado y cuál sería el mejor digitalizador para esta tarea. URL: http://digital.ni.com/public.nsf/allkb/A45E6F72D167DC6A862573AA007B8598
Replacing an Older DMM With a Newer One Results in 'Device Not Recognized' Error in Text-Based Program I replaced my PXI-4060 with the newer PXI-4065 and ran my C, CVI, or Visual Basic code. I get the error message Device not recognized. Why is this error occuring and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/A99056ACBAC7C64E8625739A00511727
NI-DAQmx Error -50103 When Performing AI and AO on an NI 4461 When I use the Multi-Device Sync-AI and AO-Shared Timebase & Trig-DSA shipping example or when I try to synchronize Analog Output (AO) and Analog Input (AI) on my NI 4461 DSA card I URL: http://digital.ni.com/public.nsf/allkb/8C7A7AF1A6DDD00086257399005B8513
动态信号采集(DSA)设备上的交流耦合能够移除多大的直流偏置? 我有一个具有很大直流偏置的信号,并想用DSA设备进行测量。交流耦合电路能够成功移除的直流偏置有限制吗?我的信号的幅值小于2.8V,而相对于板卡地的直流偏置超过12V。我还能够在交流耦合使能的情况下测量这个信号吗? URL: http://digital.ni.com/public.nsf/allkb/3CF5A29CC4F634E54825739100287DF2
How to Configure the Vertical Range per Channel of my National Instruments Digitizer? I have an NI-SCOPE device and would like to adjust the Channel 0 vertical range independently of the Channel 1 vertical range. I have tried using the niScope Configure Vertical VI but it changes the settings for both channels. How can I change the vertical ranges independently? URL: http://digital.ni.com/public.nsf/allkb/DD92BCF134C342C48625738B0065306C
NI 4498 Connector Diagram and Pinout I'm having difficulty locating the NI 4498 connector diagram with the accompanying pinout. Where can I find this? URL: http://digital.ni.com/public.nsf/allkb/0E96DC4546D1D092862573830072B519
Error-50251 When Performing Self-Calibration on My NI-5922 After Upgrading from NI-SCOPE 3.3.2 to NI-SCOPE 3.4 Previously I had NI-SCOPE 3.3.2, which I had installed from the August 2007 device driver CDs. I recently upgraded my NI-SCOPE driver to version 3.4 and now I cannot self-calibrate my NI-5922. In Measurement and Automation Explorer the self-calibrate option is disabled and I do not see any URL: http://digital.ni.com/public.nsf/allkb/B84AE4281BA524508625737C005375AF