Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: Modular Instruments / High-Speed Digitizers (Scopes) [remove] ,
21-30 of 159
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (9)
Calibration Executive (2)
Driver Software (40)
Other NI Software (1)
Hardware
AT-5102 (4)
DAQCard-5102 (6)
DAQPad-5112 for IEEE 1394 (4)
Daqpad-5102 (7)
PCI-5102 (6)
PCI-5105 (4)
PCI-5112 (11)
PCI-5114 (2)
PCI-5122 (11)
PCI-5124 (10)
PCI-5152 (2)
PCI-5911 (6)
PCI-5922 (8)
More... 
PCIe-5122 (2)
PCIe-5142 (2)
PXI-5102 (4)
PXI-5105 (2)
PXI-5112 (14)
PXI-5114 (2)
PXI-5122 (16)
PXI-5124 (7)
PXI-5152 (7)
PXI-5620 (7)
PXI-5621 (5)
PXI-5911 (5)
PXI-5922 (6)
PXIe-5122 (4)
PXIe-5142 (2)
SMB 100 (2)
SMB 110 (2)
SMB 200 (2)
SMB 300 (2)
USB-5132 (1)
USB-5133 (1)
Question Type
Bug Fix/ Error Message/ Error Code (32)
FAQ (30)
Install/Config (7)
Programming (34)
Specifications/ Documentation (43)
Unexpected Behavior/ Bad Reading (13)
Document Languages
English (78)
Spanish (9)
Japanese (24)
Chinese (Simplified) (22)
Chinese (Traditional) (12)
Korean (14)

Sort by:
21-30 of 159
|
Using NI-Scope With Traditional NI-DAQ Devices on Vista Causes System Crash on Hibernation The kernel crashes when coming out of hibernation if I am acquiring data on a PXI-5112 or PXI-5102 running when Windows Vista™ was placed into hibernation. URL: http://digital.ni.com/public.nsf/allkb/F9D9DC2335634C79862572F0005BA040
NI-Scope设备的工作温度 我在scope设备的规格书中找到了工作温度, 但是这个温度是指环境温度还是板上温度? URL: http://digital.ni.com/public.nsf/allkb/71DA4F424878A363862574A5000853B6
Operating Temperature of NI-Scope Device Scope 관련 스팩 데이터 중 Operating Temperature라는 항목을 발견했습니다. 이것은 대기중 온도를 뜻합니까, 아니면 onboard 온도를 의미합니까? URL: http://digital.ni.com/public.nsf/allkb/B71260B5F9452D1C862572DF0007773B
Operating Temperature of NI-Scope Devices I have found the Operating Temperature in the specifications for my scope device, but is this ambient temperature or onboard temperature? URL: http://digital.ni.com/public.nsf/allkb/C7A800D705665CE0862572D0007ED67A
NI High Speed Digitizers (Scopes)의 resolution을 나타내는 ENOB(Effective Number of Bits)는 무엇을 의미합니까? National Instruments의 High Speed Digitizers 디바이스의 resolution은 스팩 시트에 명확하게 언급되어 있습니다. 그런데 노이즈와 ADC의 non-linearity 특성때문에, 보드의 실제적인 resolution을 나타내는 ENOB(Effective Number of Bits)를 나타내는 스팩이 따로 존재하는 것 같아 보입니 URL: http://digital.ni.com/public.nsf/allkb/B76C5CA45BCABE61862572DF0009A86A
What is the ENOB (Effective Number Of Bits) Resolution for NI High Speed Digitizers? The resolution for National Instruments High Speed Digitizers is listed in the specifications documents for each device. However, due to noise and non-linearity of the Analog to Digital Converter (ADC), there is another specification called Effective Number of Bits (ENOB) of resolution which URL: http://digital.ni.com/public.nsf/allkb/0E4EC5883352C14F862572CE007375CA
PXI/PCI-5112での外部クロックの利用について PXI/PCI-5112で外部クロックを使って集録をしたいと思いますが、どのようにしたらいいですか? URL: http://digital.ni.com/public.nsf/allkb/B13C721DC555E979862572C30003E41C
NI-SCOPE 仿真设备 我想使用 NI-SCOPE 驱动编程,但我还没有硬件。 我能仿真一个设备从而测试我的程序吗? URL: http://digital.ni.com/public.nsf/allkb/BE13EB675C1EEDDC482572AA00319E91
Why is the NI 5105 Sampling Rate Higher Than its Timebase Frequency? The specifications for the NI 5105 digitizers list a Frequency Range of 4 Mhz to 65 MHz, but also state a Timebase Frequency of 60 MHz. Why aren't they equal? URL: http://digital.ni.com/public.nsf/allkb/F44DB529D4AAE670862572980079CB55
为什么NI 5105的采样率比它的时基还高 NI 5105数字示波器的手册上显示,其频率范围为4Mhz到65MHz,然而,同时在手册上还显示,其时基频率为60MHz,为什么最大频率和时基频率不同呢? URL: http://digital.ni.com/public.nsf/allkb/1725B4E403A34E4F86257393003445C1
Sort by:
21-30 of 159
|