Error -1074135028 When Closing Session to NI 5102
I am using an NI 5102 digitizer with the NI-SCOPE 3.5.1 driver. Whenever I stop my program using the niScope Close VI, I receive an error -1074135028, as seen below. What is causing this error and how can I fix it?
URL: http://digital.ni.com/public.nsf/allkb/16CFFA1EADEB7D99862575AE007B0EA1
|
NI VideoGenerator Memory and Image Resolution Considerations
How much memory will I need on my NI 5421 to generate a given test pattern? Also, if I am going to create my own image to generate, how should I determine the size of my image?
URL: http://digital.ni.com/public.nsf/allkb/FFAF1A417D0AC0BA862575A80054F2EA
|
What Video Standards does NI VideoMASTER Support?
Related Links: NI Developer Zone: NI VideoMASTER Software Overview and Comparison KnowledgeBase 4W0BM30O: What is the NI BNC-2178 VideoMUX and How do I Install it?
URL: http://digital.ni.com/public.nsf/allkb/2A03734EAB2B446A8625759E004C17F5
|
What is the NI BNC-2178 VideoMUX and How Do I Install It?
Problem: What is the NI BNC-2178 VideoMUX and how do I install it? Solution: Overview The NI BNC-2178 VideoMUX is a hardware accessory used with the NI 5122, to enable the acquisition and analysis of a broad variety of composite video signals. The VideoMUX consists of two distinct internal devices.
URL: http://digital.ni.com/public.nsf/allkb/B5F2312E5A6CC4098625758A005D59C7
|
Why Can't I See the RT Chassis' Device Names In the Resource Name Control In My VI?
I have a PXI controller running a real-time operating system. On my host computer I am creating an application for my modular instruments. I am currently using the niScope EX Getting Started.vi and I want to set the device I will be running on my real-time machine, but when I try to select my
URL: http://digital.ni.com/public.nsf/allkb/3C90DC50F4E91AF5862575800010139D
|
Why do I Get Error -50150 when Enabling Records > Memory and TIS?
I am trying to perform a multi-record acquisition using Time-Interleaved Sampling (TIS) with an NI-515x High-Speed Digitizer. I have both Records > Memory and TIS enabled using property nodes, but when I run my VI I get error -1074108567 with status -50150.
URL: http://digital.ni.com/public.nsf/allkb/DAE120C7B27FBB2186257551006EDCF0
|
¿Porqué La Velocidad de Muestro es Mayor Que La Frequencia Base del 5150?
Las especificaciones de la 5105 dicen que la velocidad de muestreo va desde 4 MHz a 65 MHz, también dice que la frequencia base de la tarjeta es de 60 MHz. ¿Cómo derivamos 65 MHz de una frecuencia base de 60 MHz?
URL: http://digital.ni.com/public.nsf/allkb/3CA82538A8D4363B86257535005764F2
|
How Do I Determine the DC Accuracy of the Scopes (Digitizers)?
In order to calculate the DC accuracy I will first explain the definition of accuracy then the theory behind the calculation and last and example of how to calculate the DC accuracy in our scopes.Definition:Accuracy is defined as: device ability to indicate the true value of a measured signal.
URL: http://digital.ni.com/public.nsf/allkb/63E5D3110F9DE1BE86257497007BD063
|
NI PXIe-5122 giving error -50550 or -228858
I am using an NI PXIe-5122 express digitizer to acquire data. I am receiving one of the following errors: On occasion while acquiring data I have had Error -50550 pop up, which states " A synchronization object was not acquired within the time limit. Operation could not be completed as specified."
URL: http://digital.ni.com/public.nsf/allkb/38F05FEA452185D18625746E00788AFF
|
NI PXIe-5122でエラー-50550または-228858が発生
データ集録にNI PXIe-5122デジタイザを使用していますが、使用中に以下の意味のエラーが表示されます。 データ集録中に、「エラー -50550: 同期オブジェクトは制限時間内に集録されませんでした。この操作を指定どおりに完了できませんでした。」が発生します。 このエラーが発生すると、ボードを再使用したい場合はボードをリセットするか、コンピュータを再起動するしか方法がありません。 時々、セルフキャリブレーションに失敗し、エラー"-228858"が発生しますが、再び試してみると成功することがよくあります。 このエラーの発生を防ぐ方法はありますか?
URL: http://digital.ni.com/public.nsf/allkb/91FE12F364EF457E8625758D001F977F
|