Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: Modular Instruments / Digital Multimeters (DMM) [remove] ,
21-30 of 119
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (7)
Calibration Executive (1)
Driver Software (14)
Hardware
CB-68T (2)
DAQCard-4050 (3)
DAQPad-4060 for USB (3)
PC-4060 (7)
PCI-4060 (13)
PCI-4065 (4)
PCI-4070 (26)
PCIe-4065 (3)
PXI-4022 (3)
PXI-4060 (17)
PXI-4061 (1)
PXI-4065 (4)
PXI-4070 (35)
More... 
PXI-4071 (22)
PXI-4072 (28)
TBX-68 (3)
TBX-68T (5)
USB-4065 (3)
Question Type
Bug Fix/ Error Message/ Error Code (13)
FAQ (21)
Install/Config (15)
Programming (24)
Specifications/ Documentation (38)
Unexpected Behavior/ Bad Reading (8)
Document Languages
English (62)
Spanish (4)
Japanese (9)
Chinese (Simplified) (16)
Chinese (Traditional) (18)
Korean (10)

Sort by:
21-30 of 119
|
NI DMM Error -1074118625: Volt-Hz Common Mode Limit I am using an NI DMM, and occassionally run into the following error: "Error -1074118625: niDMM Read Waveform (waveform data).vi. The Volt-Hz common mode limit has been exceeded." What does this error mean, and what can I do to remedy it? URL: http://digital.ni.com/public.nsf/allkb/A593DEBFD86A69C68625727900748EEC
Digital Multimeters with Switches in Large Chassis I have an 18-slot PXI chassis that will be using more than 10 switch modules with a DMM. Can I use the NI-DMM/Switch Express VI to perform my measurements? URL: http://digital.ni.com/public.nsf/allkb/4DEF8AD7C70E654986257260001160DB
用于热电偶测量的NI推荐硬件 NI Home This Document is not yet Rated Rate this Document 用于热电偶测量的NI推荐硬件 硬件: Multifunction DAQ (MIOE Series, Multifunction DAQ (MIOM Series, Multifunction DAQ (MIOPortable>>USB-9211A, SCXI>>Modules>>SCXI-1102, SCXI>>Terminal Blocks>>SCXI-1303, SCXI>>Modules>>SCXI-1112, SCXI>>Modules>>SCXI-1125, URL: http://digital.ni.com/public.nsf/allkb/5728F1E2C606756E4825724400233160
WHAT DOES DIGITS OF PRECISION MEAN FOR DMMS? I'm looking at the specifications for the DMM products and they are described as having a certain number of digits of precision. What does this mean and why are some DMMs described as having ½ of a digit? URL: http://digital.ni.com/public.nsf/allkb/5AD7D510F95BC5AC8625738C007C20F2
What Does Digits of Precision Mean for DMMs? I'm looking at the specifications for the DMM products and they are described as having a certain number of digits of precision. What does this mean and why are some DMMs described as having ½ of a digit? URL: http://digital.ni.com/public.nsf/allkb/CFEEE7675C76637F86257243007D0A7E
Shunt Resistors in Conjunction with Switches for Measuring Current with an NI-DMM I have a current shunt module (shunt resistor) that I’m using with an NI-DMM for measuring high levels of current, but I want to toggle between multiple current readings through the use of a switch with the shunt. Can I do this? URL: http://digital.ni.com/public.nsf/allkb/18E4CBEE31BCC1EC86257243000F870D
用 NI-DMM 量電流時與 Switch 連接的並聯電阻 我有一個電流並聯模組(並聯電阻)搭配 NI-DMM 來量高電流, 但是我希望使用 Switch 搭並聯電阻在不同的電流讀值間切換. 我可以這樣做嗎 URL: http://digital.ni.com/public.nsf/allkb/92183E516727970186257458000F65CE
使用PXI-4022和DMM进行小电流测试 我想用PXI-4022进行小电流测试,我应该如何配置它结合DMM使用啊? URL: http://digital.ni.com/public.nsf/allkb/6A307C840AC827D448257218002F2203
利用PXI-4022搭配DMM進行微小電流量測 我想用PXI-4022 URL: http://digital.ni.com/public.nsf/allkb/7B9EC9A8B3C2FDD2862573470025423A
Decreasing the digits of resolution on my DMM causes incorrect readings when measuring coil resistance. I am measuring a coil resistance. When I set my DMM to measure at 6.5 digits of resolution my readings are all good. When I read at 5.5 Digits my readings are off by +/-5 Ohms. When I measure at 4.5 Digits my readings are off by about +/-10 Ohms. When I am measuring resistance in the 50 URL: http://digital.ni.com/public.nsf/allkb/D99D0C3EE1E6846086257206003C0E6F