Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: Compact FieldPoint / Connector Blocks [remove] ,
1-9 of 9
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
cFP-CB-1 (1)
cFP-CB-11 (1)
cFP-CB-3 (1)
Question Type
Bug Fix/ Error Message/ Error Code (1)
FAQ (1)
Specifications/ Documentation (7)
Document Languages
English (8)
Japanese (1)

Sort by:
1-9 of 9
What are the pinouts for the cFP-CB-11? I am trying to find the pinouts for the cFP-CB-11. Where can I find this information? URL: http://digital.ni.com/public.nsf/allkb/2DA50514A6ADD94686257465005C0813
Can I Use the 37-Pin Female to Pigtail Compact Fieldpoint Cable with the PCI-6239 Card? I have a PCI-6239 card and a Compact FieldPoint controller. I noticed that both devices use the same 37-pin female to male shielded cable (Part number: 778621-01). I have also noticed that the Compact FieldPoint (cFP) controller has another recommended cable that maps out the 37-pin connector URL: http://digital.ni.com/public.nsf/allkb/193AB425E3266FC18625727A0061106B
Compact FieldPoint cFP-TC-120 and cFP-CB-3 Product Notification Information As noted in our recent product notification letter, National Instruments recently discovered that revision B of the cFP-TC-120 may not meet performance specifications when operating in environments at the extreme ends of the operating temperature range. Furthermore, revisions A and B URL: http://digital.ni.com/public.nsf/allkb/0C86B0BD02BB1AC68625700E0074A04D
EシリーズデバイスとSCXIシャーシでSH68-68-D1ケーブルを使用する上での問題 EシリーズDAQボードとSCXIをSH68-68ケーブルで繋いでいます。SCXIシャーシが、Measurement and Automation Explorer(MAX)で認識されません。インストール手順にも問題はありません。何が問題なのでしょうか。 URL: http://digital.ni.com/public.nsf/allkb/7CA5903F1A1B70F286256F4F001FCE59
Problems Using SH68-68-D1 Cable With E Series Device and SCXI Chassis? I have an SH68-68 cable connecting my SCXI chassis to an E Series Data Acquisition (DAQ) board. The chassis is not detected in Measurement and Automation Explorer (MAX), but everything else seems to be installed correctly. What's wrong with my setup? URL: http://digital.ni.com/public.nsf/allkb/EFB318B34595307B86256CA0006A48CC
Bad Readings from Thermocouple with the SC-2071 Accessory Why am I getting bad readings from my thermocouple on the SC-2071? In the test panels, the voltage I am reading is greater than 2 mV. URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C862566470058BCDB
Bad Readings from Thermocouple with the SC-2071 Accessory Why am I getting bad readings from my thermocouple on the SC-2071? In the test panels, the voltage I am reading is greater than 2 mV. URL: http://digital.ni.com/public.nsf/allkb/F28A990C57905A01862570F2005E7B92
What are the USER1 and USER2 BNC Connectors on the BNC-2090? The BNC-2090 has two BNC connectors named USER1 and USER2. What is their purpose? URL: http://digital.ni.com/public.nsf/allkb/E10E39C6271502C5862565DA00267133
Wire Gauge Sizes for DAQ Connector Blocks and SCXI Terminal Blocks What gauge wire can our DAQ connector blocks and SCXI terminal blocks take? URL: http://digital.ni.com/public.nsf/allkb/82A2CE405817E8D78625618700519A37
Sort by:
1-9 of 9