Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Hardware
:
Compact FieldPoint
/ Analog I/O Modules [
remove
] ,
1-10 of
34
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Calibration Executive
(1)
Driver Software
(1)
LabVIEW Development Systems
(1)
Hardware
cFP-AI-100
(7)
cFP-AI-102
(3)
cFP-AI-110
(6)
cFP-AI-111
(6)
cFP-AIO-600
(1)
cFP-AIO-610
(4)
cFP-AO-200
(3)
cFP-AO-210
(3)
cFP-RTD-122
(3)
cFP-RTD-124
(3)
cFP-SG-140
(2)
cFP-TC-120
(8)
Question Type
Bug Fix/ Error Message/ Error Code
(4)
FAQ
(11)
Install/Config
(6)
Programming
(4)
Specifications/ Documentation
(8)
Unexpected Behavior/ Bad Reading
(1)
Document Languages
English
(19)
Spanish
(1)
French
(1)
Japanese
(1)
Chinese (Simplified)
(7)
Korean
(5)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
34
Next
How to Build a Current Loop System with Compact FieldPoint?
I want to build a 4 - 20 mA current loop system with Compact FieldPoint. Which module should I use and configurations are possible?
URL:
http://digital.ni.com/public.nsf/allkb/7BC3FBF060AB9D60862573F600786B71
How to Build a Current Loop System with CompactRIO?
I want to build a 4 - 20 mA current loop system with CompactRIO (cRIO). Which module should I use and configurations are possible?
URL:
http://digital.ni.com/public.nsf/allkb/5A30CD178637BFA5862573F700003BAD
读取FieldPoint输出模块上的输出值
在LabVIEW应用程序中,我从FieldPoint模块的模拟输出通道上写了一些值。如何在程序中确定当前写到FieldPoint模块的输出值?
URL:
http://digital.ni.com/public.nsf/allkb/A3AE048E7783C422482573A2001D259F
[c]FP-SG-140 Returns Noisy or Fluctuating Measurements
Problem: Why does my [c]FP-SG-140 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that revision G and earlier FieldPoint and Compact FieldPoint [c]FP-SG-140 modules can exhibit abnormal fluctuation in their readings.
URL:
http://digital.ni.com/public.nsf/allkb/0461C1946084BA74862573530071BA4F
How Does the [c]FP-SG-140 Determine mV/V and What Power Supply Do I Need?
I am measuring strain gauges with the [c]FP-SG-140. The values it returns are in mV/V, where mV is the strain and the V is excitation voltage. I have setup the excitation voltage in MAX to be 5 Volts. Will the readings always be divided by 5, or is the module reading the actual excitation
URL:
http://digital.ni.com/public.nsf/allkb/6CE21845D7E42EAA8625732D0072D0AB
[c]FP-RTD-124 Returns Noisy or Fluctuating Measurements
Problem: Why does my [c]FP-RTD-124 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that FieldPoint and Compact FieldPoint [c]FP-RTD-124 modules may take noisy or fluctuating measurements at power up. Often, measurements stabilize after several seconds.
URL:
http://digital.ni.com/public.nsf/allkb/3784655EFDDDE51E862572CF007A7D62
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration?
I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but
URL:
http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
如何使用NI的产品测量电流?
我想进行电流测量,但是我不知道哪种NI产品可以测量电流并且如何测量?
URL:
http://digital.ni.com/public.nsf/allkb/D84290C812ED19164825726700401FB7
哪些美国国家仪器的产品可以被用来作为电流输出?
c[FP]-AIO-600 - 8通道,单端参考地,模拟输入/输出混合模块,内部更新率可达1.
URL:
http://digital.ni.com/public.nsf/allkb/51560496185576ED4825725D002D9E45
[c]FP-TC-120的电磁抗干扰性
当[c]FP-TC-120暴露在电磁场中时,传感器会感生出电压,这会引入错误数据。
URL:
http://digital.ni.com/public.nsf/allkb/2070E4D82096922B4825725C00322D42
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
34
Next
Search KnowledgeBase Documents: