How Do I Use the Digital Input/Output Lines on my 7330, 7340, or 7350 Motion Controller Card?
How do I program the Digital Input/Output (DIO) lines on my NI 7330, 7340, or 7350 Motion Controller card?
URL: http://digital.ni.com/public.nsf/allkb/2D238C3BF101620C862573A60081BFFE
|
What is the Difference Between a Soft Reboot and a Hard Reboot on a Real-Time FieldPoint Controller?
What is the difference between a soft reboot and a hard reboot on a real-time FieldPoint controller?
URL: http://digital.ni.com/public.nsf/allkb/C268F401137B3D14862573A600771CB4
|
Why Do I Receive VISA Error 0xBFFF00A7 and NI-RIO Error -63040 Under My CompactRIO Controller in MAX?
I’ve connected my CompactRIO target to my network. However, when I look under remote systems in Measurement and Automation Explorer (MAX) on my host PC, I can see the controller, but under Devices and Interfaces I see both VISA error
URL: http://digital.ni.com/public.nsf/allkb/5BBA8F279C449E828625739300040621
|
LabVIEW RT でのUSBメモリへのアクセス方法(ドライブ名)
LabVIEW RT 8.2以降で、USB接続のハードディスクやUSBメモリへのアクセスがサポートされるようになりましたが、RTコントローラにUSBメモリを挿入して、プログラムで、”D:¥”や”E:¥”としてアクセスしようとしてもアクセスできません。USBメ■>
URL: http://digital.ni.com/public.nsf/allkb/A32A7955141169308625738D0006E53F
|
What Do I Do When the Status LED on my cFP-2020 Stays Lit?
I just powered up my cFP-2020 and the Status LED is staying lit. According to the cFP-20xx manual, the controller did not power up correctly and I should contact National Instruments. How do I fix this?
URL: http://digital.ni.com/public.nsf/allkb/2BAB7963FD9286B18625738B000495DC
|
我应当怎么做如果我的cFP-2020持续点亮?
当我给我的cFP-2020上电的时候,状态指示灯持续点亮. 参考cFP-20xx的用户手册, 是由于控制器并没有正确的被上电,应当联系National Instruments. 我应该怎么做才可以解决这个问题?
URL: http://digital.ni.com/public.nsf/allkb/C3C035244D1E95E7862573CA004712F8
|
我要如何觀看連結至Compact RIO上USB Flash Drive中的資料?
我將USB flash drive連接至Compact RIO上,但是要如何在我的電腦上來觀看資料呢?
URL: http://digital.ni.com/public.nsf/allkb/B22A15B34FA1940B862573B500069F83
|
LabVIEW RT Memory Usage on FieldPoint Controllers
I don't know how much memory and storage are left for my applications when I install and run software on my FieldPoint controller.
URL: http://digital.ni.com/public.nsf/allkb/EEC34DB19DD2B40A86257377006BD663
|
512 MB Compact Flash Product Notification FAQ
Information on the 512 MB Compact Flash Product NotificationOnly the following products shipped between December 1, 2006 and September 10, 2007 are affected: cRIO-9004 cFP-2020 - Only with 512 MB Compact Flash cards in the
URL: http://digital.ni.com/public.nsf/allkb/C64D8FF78DADB84E862573600071F65D
|
Why Does My cRIO Controller Not Show Up in MAX?
Why doesn't my cRIO controller show up under Remote Systems in the Measurement and Automation Explorer (MAX)?
URL: http://digital.ni.com/public.nsf/allkb/ABE4BC247E8AC9BC8625734E005CAB42
|