How Can I Setup the FieldPoint Watchdog When Connected With a Serial Cable?
I have a FieldPoint network module, and I can setup and use the FieldPoint Watchdog timer when using TCP/IP. However, when I connect to the FieldPoint network module with a serial cable, the watchdog timer continues to fire even though the cable is still connected. Why?
URL: http://digital.ni.com/public.nsf/allkb/BA951FB049D4E4FD862575D7005B0308
|
Network Settings For Using Windows XP Remote Desktop With A PXI Controller
What network settings do I need to change on my PC and my PXI Controller in order to use Windows XP Remote Desktop to control the PXI Controller from my PC?
URL: http://digital.ni.com/public.nsf/allkb/78AE3DB4926FDA68862575D7006FC122
|
CompactRIO Controller Installation Issue: Connected - Safe Mode (Improper Installation)
I have just received my compactRIO controller and after installing LabVIEW RT software, the controller boots into SafeMode with the status of Connected - Safe Mode (Improper Installation). How do I get my CompactRIO controller out of this state?
URL: http://digital.ni.com/public.nsf/allkb/B2BA1B006C12B1A2862575D60044E192
|
How Do I Connect a Pressure Transducer to the cFP-AI-110?
I have a pressure transducer that I want to use with the cFP-AI-110 module. How do I wire it?
URL: http://digital.ni.com/public.nsf/allkb/491FA7C7F2713BF1862575CC007F7AE5
|
Where can I find out what products need calibrating?
I have a National Instruments device and need to know whether I need to calibrate it or not. Where can I find this information?
URL: http://digital.ni.com/public.nsf/allkb/05DCF4B44AC68BEB862575CB00499A4B
|
Can I Use LabVIEW Shared Variables with LabVIEW Items on Compact FieldPoint?
I would like to use the LabVIEW Shared Variable with a LabVIEW Item on a Compact FieldPoint (cFP) rather than a FieldPoint Read. How do I do this?
URL: http://digital.ni.com/public.nsf/allkb/70ADB10B443988F5862575C50061F28A
|
Error al Desplegar el Proyecto de LabVIEW Cuando se usa cFP-180x
El proyecto de LabVIEW, si doy clic derecho en el banco FP para desplegar los cambios realizados, por ejemplo, al "Watchdog", muestra el siguiente mensaje de error: "Bank Error deploying FieldPoint configuration: The module addressed is not of the selected type." o "The FieldPoint server cannot
URL: http://digital.ni.com/public.nsf/allkb/4D470AEA9D7804F0862575C300835172
|
How to Set CJC Source Attribute of the CJ Temperature channel with a cFP-TC-120
I have a cFP-TC 120 and I want to use a software algorithm for cold junction compensation. The FP-TC-120 and cFP-TC-120 Operating Instructions manual states that to perform this operation it is necessary to set the CJC Source attribute of the CJ Temperature channel to either 0° or 25°. Which
URL: http://digital.ni.com/public.nsf/allkb/9996F09082DAFFC0862575B70047F92F
|
Voltage Loss Through AWG Wire
Problem: What is the voltage loss through AWG wire? Solution: Voltage loss is a function of the current, cable length, and cable resistance.
URL: http://digital.ni.com/public.nsf/allkb/DA8D6F7B62FE96D8862575B70057F181
|
Cannot Read UTC Time From My Real-Time Controller
I have set my controller to Coordinated Universal Time (UTC) in Measurement & Automation Explorer (MAX), but my controller is still returning local time. Why is this happening?