Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: Legacy DAQ Devices / Analog Output [remove] ,
1-6 of 6
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
AT-AO-10 (6)
AT-AO-6 (1)
Question Type
Bug Fix/ Error Message/ Error Code (2)
Install/Config (1)
Specifications/ Documentation (3)
Document Languages
English (5)
Spanish (1)

Sort by:
1-6 of 6
Why am I Receiving Error -10401 When Outputting a Voltage in a Test Panel with my AT-AO-6/10 Board? I have an AT-AO-6/10 board installed on my computer. It shows up in both MAX and device manager. When I run a test panel in MAX, however, I receive a -10401 error. Why is this? URL: http://digital.ni.com/public.nsf/allkb/AE786749D6E63C0286256E8E0023946E
Running the Test Panel on an AT-AO-10 Causes a Reboot I am using either NI-DAQ 6.7 or 6.8.1 and running the test panel on the AT-AO-10, and this causes my system to instantly reboot. I tested this on several different computers and several different AT-AO-10 cards with the same result. URL: http://digital.ni.com/public.nsf/allkb/48AB18545EA20C278625699D0078BC7A
My Board Is Labeled AT-AO-6/10, but Do I Have an AT-AO-6 or an AT-AO-10? How do I tell the difference between an AT-AO-6 and an AT-AO-10 card when the board is labeled AT-AO-6/10? URL: http://digital.ni.com/public.nsf/allkb/E4E961BAFC1B5D3B8625698C0057D4EF
Various Errors Using Channels 8 and 9 on the AT-AO-10 Channels 8 and 9 on the AT-AO-10 are handled differently than channels 0 through 7, and this difference can result in the following errors when improperly accessed:In the Measurement & Automation Explorer (MAX) test panel, performing sine wave output on channels 8 or 9 results in the error URL: http://digital.ni.com/public.nsf/allkb/13D559256EEE84408625698C0059551F
Configuración de Tarjetas PnP Utilizando NI-DAQ para Windows NT Después de agregar una tarjeta DAQ PnP (Plug and Play) en la Utilería de Configuración de NI-DAQ y seleccionar una dirección (base address) y después de oprimir 'Apply' u 'OK' puede aparecer un mensaje de error 'Failed to Assign Resource' con el botón de 'Test' en gris. Puede encontrar que ciertas URL: http://digital.ni.com/public.nsf/allkb/862567530005F0A18625699000592804
Does the AT-AO-10 Require +/- 12V and +5V for Power Like the AT-AO-6, or Just +5V? The documentation lists the following:Power Requirements (from PC AT I/O Channel)AT-AO-6+5 VDC 0.6 A typical+12 VDC 60 mA typical + load-12 VDC 60 mA typical + loadAT-AO-10+5 VDC 1.6 A typicalIs this a misprint on the AT-AO-10 section? URL: http://digital.ni.com/public.nsf/allkb/522BC43F027D8466862566D6005EF8CC
Sort by:
1-6 of 6