Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Hardware
: FieldPoint / Analog I/O Modules [remove] ,
1-10 of 95
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (2)
Driver Software (1)
Hardware
FP-AI-100 (8)
FP-AI-102 (4)
FP-AI-110 (24)
FP-AI-111 (4)
FP-AI-112 (1)
FP-AI-118 (1)
FP-AIO-600 (3)
FP-AO-200 (8)
FP-AO-210 (1)
FP-RTD-122 (9)
FP-RTD-124 (4)
FP-SG-140 (11)
FP-TC-120 (33)
Question Type
Bug Fix/ Error Message/ Error Code (6)
FAQ (12)
Install/Config (11)
Programming (19)
Specifications/ Documentation (41)
Unexpected Behavior/ Bad Reading (6)
Document Languages
English (59)
Spanish (5)
Japanese (4)
Chinese (Simplified) (11)
Chinese (Traditional) (2)
Korean (14)

Sort by:
1-10 of 95
[c]FP-SG-140 Returns Noisy or Fluctuating Measurements Problem: Why does my [c]FP-SG-140 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that revision G and earlier FieldPoint and Compact FieldPoint [c]FP-SG-140 modules can exhibit abnormal fluctuation in their readings. URL: http://digital.ni.com/public.nsf/allkb/0461C1946084BA74862573530071BA4F
[c]FP-RTD-124 Returns Noisy or Fluctuating Measurements Problem: Why does my [c]FP-RTD-124 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that FieldPoint and Compact FieldPoint [c]FP-RTD-124 modules may take noisy or fluctuating measurements at power up. Often, measurements stabilize after several seconds. URL: http://digital.ni.com/public.nsf/allkb/3784655EFDDDE51E862572CF007A7D62
如何增加FieldPoint或者cRIO RTD模块的范围? 我有一个RTD,其电阻值超出了我的RTD模拟输入模块指定的测量范围。可否扩展最大阻值以使我的RTD能够测量? URL: http://digital.ni.com/public.nsf/allkb/3437EF0534231DEC482572BA0012011F
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration? I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but URL: http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
如何使用NI的产品测量电流? 我想进行电流测量,但是我不知道哪种NI产品可以测量电流并且如何测量? URL: http://digital.ni.com/public.nsf/allkb/D84290C812ED19164825726700401FB7
哪些美国国家仪器的产品可以被用来作为电流输出? c[FP]-AIO-600 - 8通道,单端参考地,模拟输入/输出混合模块,内部更新率可达1. URL: http://digital.ni.com/public.nsf/allkb/51560496185576ED4825725D002D9E45
[c]FP-TC-120的电磁抗干扰性 当[c]FP-TC-120暴露在电磁场中时,传感器会感生出电压,这会引入错误数据。 URL: http://digital.ni.com/public.nsf/allkb/2070E4D82096922B4825725C00322D42
为什么在 FieldPoint FP-TC-120的热电偶输入通道上发现有电压输出? 当我用万用表去测量FP-TC-120的热电偶输入通道时,我测到了一个电压输出。为什么没有热电偶连接时,我能从热电偶输入通道测到一个电压? URL: http://digital.ni.com/public.nsf/allkb/6C276A563855DE0E4825725C00314C67
当接上热电偶时,为什么[c]FP-TC-120的LED不亮? 当我将热电偶接上[c]FP-TC-120模块时,为什么表明热电偶已连上的红色LED不亮?我怎么才能使LED亮呢? URL: http://digital.ni.com/public.nsf/allkb/B368D960358584234825725C002F8714
我怎么提高FP-TC-120的测量精度? 在 FP-TC-120的数据手册上,0.2 C 错误被描述为 '当使用FP-TB-3等温底座时,冷端传感器温度和接线端实际温度间的误差', 有没有什么测量方法可以最小化这个误差? URL: http://digital.ni.com/public.nsf/allkb/E08725D6B8FA693E4825725C0033D773