Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Hardware
:
Switches
/ General-Purpose [
remove
] ,
1-10 of
29
KnowledgeBase [
see results below
]. To refine your results, select another category.
Hardware
ER-16
(2)
FP-RLY-420
(7)
FP-RLY-422
(5)
PXI-2567
(1)
PXI-2569
(2)
PXI-2570
(3)
PXI-2598
(2)
PXI-2599
(2)
SCXI-1160
(4)
SCXI-1161
(2)
SCXI-1166
(2)
SCXI-1167
(1)
SCXI-1169
(1)
More...
SCXI-1192
(1)
cFP-RLY-420
(3)
cFP-RLY-421
(4)
cFP-RLY-422
(3)
cFP-RLY-423
(3)
cFP-RLY-425
(3)
Question Type
Bug Fix/ Error Message/ Error Code
(3)
FAQ
(5)
Install/Config
(1)
Programming
(5)
Specifications/ Documentation
(12)
Unexpected Behavior/ Bad Reading
(3)
Document Languages
English
(21)
Spanish
(1)
Chinese (Simplified)
(3)
Chinese (Traditional)
(1)
Korean
(3)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
29
Next
ER-16 Not Powering On
The ER-16's red power up LED is not turning on and it is not appearing in Measurement and Automation Explorer (MAX). Why won't the power LED turn on?
URL:
http://digital.ni.com/public.nsf/allkb/4AC03EECC0ADC53A8625742C00620A3A
LFH200 Bare Wire Cables with Date Codes 3707 and 5007 Have Incorrect Pinouts
On the LFH200 Bare Wire cable, Leg J2, Leg J3, Leg J6 and Leg J7 have mismatched wire color codes when compared with the pin assignment table given in the LFH200 Cable Installation Instructions. This
URL:
http://digital.ni.com/public.nsf/allkb/F6C3FFFAC2A65970862573E7007F822E
Unexpected Relay Behavior on [c]FP-RLY-42x Modules
When I write to one or more channels on a [c]FP-RLY-42x module, other channels on that module or adjacent modules exhibit unexpected behavior. Why is that?
URL:
http://digital.ni.com/public.nsf/allkb/246152C8859CE715862573C60070728F
¿Cuáles son los Requisitos de CPU para Utilizar mi Tarjeta de Serie M?
He tratado de buscar en la Web pero no he encontrado ningún requisito de CPU para utilizar mi tarjeta de Serie M. ¿Cuáles son los requisitos de
URL:
http://digital.ni.com/public.nsf/allkb/D205178A4E45BF1F86257362001FC76B
26.5GHz Switch 모듈을 사용하고 있습니다. 26.5GHz 이하에서 동작하는 어플리케이션에 사용할 수 있습니까?
26.5GHz RF Switch를 이용해서 프로젝트를 진행해본적이 있습니다. 그리고 새 프로젝트를 진행하는데, 새롭게 적용하게 될 디바이스들을 최소한으로 줄이려고 합니다. 새 프로젝트에서는 26.5 GHz 신호보다 낮은 주파수의 신호를 사용하는데 해당 Switch를 그대로 적용■>
URL:
http://digital.ni.com/public.nsf/allkb/143D65FC86B8A559862572E30005F671
Can I Use a 26.5 GHz Switch for Applications Operating at Lower Frequencies?
I have a 26.5 GHz RF switch that I had been using for a previous project and I would like to minimize the amount of new equipment I need for my new project. Can I simply use my 26.5 GHz switch for this application even though the frequency will not be anywhere near 26.5 GHz?
URL:
http://digital.ni.com/public.nsf/allkb/C902247C2F205F8F862572D200608F97
NI Switches and AC Wall Power Compatability
Which NI Switches can be used to switch AC wall power? I tried using the SCXI 1166 to switch wall power, but it didn't operate as expected.
URL:
http://digital.ni.com/public.nsf/allkb/855AF9CBDAACE3018625725A00638653
NI Switch和AC壁装电源的兼容性
哪些NI Switch可以用于开关AC壁装电源? 我试着用SCXI 1166来开关壁装电源,但是没有得到预期结果。
URL:
http://digital.ni.com/public.nsf/allkb/A79A0BF785A2B3668625739100347257
Troubleshooting an ER 16 Behaving Incorrectly
The relays on the ER 16 are not behaving as expected when being controlled by PCI-DIO 32HS (6533). In the MAX Test Panel, when writing to the ports, the corresponding LEDs on the ER 16 do not behave as expected.
URL:
http://digital.ni.com/public.nsf/allkb/F03497B561D77749862570140062F5EF
PXI-2569 Path Capacitance
What is the capacitance of the relays in the PXI-2569 switch module? What is the total path capacitance of each channel?
URL:
http://digital.ni.com/public.nsf/allkb/A44ED7EE5E7D224386256FF50057633A
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
29
Next
Search KnowledgeBase Documents: