为什么当在标定PXI-5112时,它的输入阻抗是750K欧姆?
我使用Datron/Wavetek 1281 (1281是一个8.5位的数字万用表)测量PXI-5112的输入阻抗(用标定执行器)。我应该在40V,4V,0.4V所有这些量程上都得到1M欧姆的输入阻抗。问题是,当我运行这个测试时,在40V和4V量程上得到1M输入阻抗。但在0.4V量程上得到750K欧姆。
URL: http://digital.ni.com/public.nsf/allkb/35A860493D953D2E86256F090022EE81
|
Verify Board Calibration Without Adjusting Calibration Constants
Is there a way to verify that my data acquisition device is properly calibrated without adjusting the calibration constants stored in the device's EEPROM?
URL: http://digital.ni.com/public.nsf/allkb/C473213FAB6835F186256EDD008268CA
|
Calibration Executive 2.2.1 File Extractor May Cause New Procedures to Appear in the Calibration Executive Wizard
I installed the Calibration Executive 2.2.1 file extractor and it caused new procedures to appear in the Calibration Executive Wizard. Why did this happen?
URL: http://digital.ni.com/public.nsf/allkb/20C0C9781D37AECD86256EA6004D5A15
|
Calibration Executive 2.2 Hangs when Opening a Report
Calibration Executive sometimes hangs when trying to open a report. The problem seems to be in the LV Run Time Engine (RTE), which is used by the report generator.
URL: http://digital.ni.com/public.nsf/allkb/24AEFA741E9BAD2086256E9900589E5F
|
Error Message 'Calibration Sequence Error' when running the Calibration Procedure.
When I run the Calibration Executive procedure, the first two steps including the self-calibration are properly passed, but the third step is failing. I obtain the following message "Calibration Sequence Error", and the execution stops and a blank report is generated (see below). It occurs in
URL: http://digital.ni.com/public.nsf/allkb/94F9A85CB634D0BD86256E8500552394
|
Calibration Executive를 64비트 프로세서에서 실행할 수 있습니까?
NI의 Calibration Executive 소프트웨어를 AMD64 또는 Intel Itanium 등의 64비트 프로세서에서 사용하고 싶습니다. 실행이 가능합니까?
URL: http://digital.ni.com/public.nsf/allkb/2FD9F96FD498A4EB86256E850046111C
|
Can Calibration Executive Run on 64-bit Processors?
I would like to use NI's Calibration Executive software on a 64-bit processor, either AMD64 or Intel Itanium for example. Is this possible?
URL: http://digital.ni.com/public.nsf/allkb/5C93D0B36E4A841986256E7700795574
|
Can the SCXI-1100 or 1102 be Calibrated with the Current Resistors Installed?
I have configured my SCXI-1100 for current measurements by installing the process-current resistors as shown on page 2-9 of the SCXI-1100 user manual (page 2-4 of the SCXI-1102/B/C User Manual). I would like to calibrate my SCXI module with Calibration Executive. Do I have to change this setup in
URL: http://digital.ni.com/public.nsf/allkb/3E6759BB31D0539D86256E77007CBCDD
|
Does Calibration Executive Support the SCXI-1102B, SCXI-1102C, SCXI-1104C, or SCXI-1120D?
In numerous locations that list the SCXI modules supported by Calibration Executive, the SCXI-1102, SCXI-1104, and SCXI-1120 are included, but the B, C, and D variations of these modules are not. Are these SCXI modules supported by Calibration Executive?
URL: http://digital.ni.com/public.nsf/allkb/F7313C35709D3C1986256E5A0069C8A0
|
Last Calibration Date Window Displays Incorrect Date
When running an external calibration procedure with Calibration Executive 2.2, the 'Last Calibration Date' window displays the original factory calibration date, even if I performed a new calibration recently, similar to the following figure.
URL: http://digital.ni.com/public.nsf/allkb/3F96293F5EC61FE186256E580071CF07
|