How Can I Test a Device that Requires Excitation in MAX? I am testing my SCXI device using test panels in Measurement & Automation Explorer (MAX) but the values aren't what I'm expecting. Is something wrong with my device? URL: http://digital.ni.com/public.nsf/allkb/C2553DEE2E3CF1BE862573A30062C1F3
Error -200077 (0xFFFCF273) During Thermocouple Measurements with SCB-68 or SCXI Why is using a DAQ device with the SCB-68 or SCXI-1102 for Thermocouple Measurements with Built-In CJC Compensation Yield -200077 Error? URL: http://digital.ni.com/public.nsf/allkb/E740DA479107B1468625703B0077037B
Error -200077 (0xFFFCF273) al Realizar Mediciones con Termopares utilizando un SCB-68 o un SCXI ¿Por qué al utilizar un dispositivo DAQ con un SCB-68 o un SCXI-1102 para Mediciones de Termopares con Compensación de Unión Fría (CJC) Interna (Built-In) URL: http://digital.ni.com/public.nsf/allkb/B5C1198004968935862573840003C1ED
SCB-68 또는 SCXI로 Thermocouple을 측정하려고하면 -200077(0xFFFCF273)에러가 발생합니다. SCB-68 또는 SCXI-1102 내부에 있는 CJC 보상회로를 이용하여 DAQ장비로 Thermocouple 측정하려고 하면 왜 -200077(0xFFFCF273)에러가 발생합니까? URL: http://digital.ni.com/public.nsf/allkb/97852302224A53EC862571BD000A9C19
為什麼在我的DAQmx Base Configuration Utility中看不到SCXI模組設定? 我要用DAQmx Base並且透過SCXI來擷取訊號,但我卻無法在DAQmx Base Configuration Utility中顯示出SCXI的模組出來。 URL: http://digital.ni.com/public.nsf/allkb/79F67CB6240E65C98625700D0002B49D
Why Does Measurement & Automation Explorer (MAX) Freeze When I Try to Auto-Detect My SCXI Modules Using Traditional DAQ? I go under Devices and Interfaces and right-click on Traditional DAQ Devices and Add an SCXI Chassis. I then follow the prompts selecting the Chassis Type, Chassis ID, and Chassis Address, but when I select Yes to Auto-Detect Modules Measurement & Automation Explorer (MAX) freezes. URL: http://digital.ni.com/public.nsf/allkb/0FA44B20777D77C186256F8700011D65
Error -10635 when Running SCXI-1520 Calibration Executive Procedure with SCXI-1001 Chassis The following error occurs when running the SCXI-1520 Calibration Executive Procedure with an SCXI-1001 Chassis.Error -10635, Error Message: invalid SCXIOpModeError: Either the SCXI operating mode specified in a configuration call is invalid, or a module is in the wrong operating mode URL: http://digital.ni.com/public.nsf/allkb/863A7527267B772B86256F0400532E92
User Specified Excitation Values for Virtual Channels. While setting up virtual channels in Measurement and Automation Exporer (MAX), can I control the amount of excitation provided by the SCXI Modules to my sensor if I set the excitation value to be user specified? URL: http://digital.ni.com/public.nsf/allkb/3969C232D0A5656886256DBB00762B9A
Why Does the Test Panel for My SCXI Module Seem So Slow? I am trying to test an SCXI module, such as the SCXI-1531, in a MAX test panel. but it seems to read very slowly. Why is this occurring? URL: http://digital.ni.com/public.nsf/allkb/ABD1791C417660A786256DB70050FBCB
써머커플에 대한 버추얼 채널에 냉접접보상(CJC)값이 갖추어져(Built In) 있지 않을 경우. Measurement & Automation Explorer (맥스)에서 버추얼 채널을 설정할때,냉접점보상의 소스에 대한 선택이 사용자 값(User value)에 의한 설정입니다. 반면에 터미널 단자에는 써머커플 입력을 위한 냉접점보상(CJC)을 정밀하게 해주는 온도센서를 가지고 있습니다. 이 온보드 냉 URL: http://digital.ni.com/public.nsf/allkb/09E06C7FC0FFC9DB86256E350010483B