Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
: Utility Software [
remove
] ,
Hardware
: Multifunction DAQ (MIO) [
remove
] ,
11-20 of
21
KnowledgeBase [
see results below
]. To refine your results, select another category.
Hardware
Connector Blocks
(10)
E Series
(4)
M Series
(1)
Portable
(1)
Question Type
Bug Fix/ Error Message/ Error Code
(10)
Install/Config
(7)
Programming
(3)
Unexpected Behavior/ Bad Reading
(1)
Document Languages
English
(10)
Spanish
(3)
Japanese
(3)
Chinese (Simplified)
(1)
Chinese (Traditional)
(2)
Korean
(2)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
21
Previous
|
Next
Error -200077 (0xFFFCF273) al Realizar Mediciones con Termopares utilizando un SCB-68 o un SCXI
¿Por qué al utilizar un dispositivo DAQ con un SCB-68 o un SCXI-1102 para Mediciones de Termopares con Compensación de Unión Fría (CJC) Interna (Built-In)
URL:
http://digital.ni.com/public.nsf/allkb/B5C1198004968935862573840003C1ED
Error 50103 en DAQmx Start Task
Estoy utilizando VIs de DAQmx para adquirir datos y cuando intento correr mi aplicación, obtengo el siguiente mensaje de error: Error 50103 occured at an unidentified location¿Cuál es la causa de este error?
URL:
http://digital.ni.com/public.nsf/allkb/F8E05086B65729068625748E005C5431
Error 50103 於 DAQmx Start Task
我使用DAQmx VIs做資料擷取,當我一執行程式時,出現以下錯誤: Error 50103 occured at an unidentified location此錯誤訊息的原因為何?
URL:
http://digital.ni.com/public.nsf/allkb/94155DB931C82BA986257146002D93F4
SCB-68 또는 SCXI로 Thermocouple을 측정하려고하면 -200077(0xFFFCF273)에러가 발생합니다.
SCB-68 또는 SCXI-1102 내부에 있는 CJC 보상회로를 이용하여 DAQ장비로 Thermocouple 측정하려고 하면 왜 -200077(0xFFFCF273)에러가 발생합니까?
URL:
http://digital.ni.com/public.nsf/allkb/97852302224A53EC862571BD000A9C19
Channels Crossed Out in MAX When Using the NIConfig.daq File
Why all of my are channels crossed out in MAX, when I copied my NIConfig.daq file from another computer?
URL:
http://digital.ni.com/public.nsf/allkb/4F14F26324542F6086256F4D001CBC10
How do I Set Programmable Power Up States and What Boards Support them?
How Do I Set Programmable Power Up States and What Boards Support Them?
URL:
http://digital.ni.com/public.nsf/allkb/A98392F93E54D07786256E6F004DE4C3
BNC-2110の端子台を671xと673x型のアナログ出力デバイスと組み合わせて使用することに関して。
671xあるいは673x型のアナログ出力デバイスにBNC-2110端子台を使用したい場合、Measurement & Automation Explorer (MAX)の設定画面で、BNC-2110はアクセサリの一覧に出てきません。どうしたらよいでしょうか?
URL:
http://digital.ni.com/public.nsf/allkb/5227C69E6521E7FF862570DC001F190D
Using the BNC-2110 with 671x and 673x Analog Output Devices
When I try to configure my 671x or 673x analog output device to use the BNC-2110 as an accessory, Measurement & Automation Explorer (MAX) does not list the BNC-2110 as an option. What should I do?
URL:
http://digital.ni.com/public.nsf/allkb/5E5DFEF10C256A1A86256D7F0063CD92
Error -10401 When Swapping PCMCIA DAQ Cards
I have a LabVIEW application that uses a PCMCIA DAQCard-AI-16E-4. I have multiple DAQCards that I am using with the same LabVIEW application. When I shut down my laptop and insert another DAQCard-AI-16E-4 into the same PCMCIA slot of my laptop and then run my application, I receive error -10401.
URL:
http://digital.ni.com/public.nsf/allkb/23B5918E5604915B86256C2B005F4D70
PCMCIA DAQカードを入れ替えた際にエラー -10401が発生します
PCMCIA DAQCard-AI-16E-4を使用したLabVIEWのアプリケーションを用いてデータ集録を行っています。DAQカードを複数枚所有していて、同じアプリケーションを用いて使用しているのですが、ラックトップPCをシャットダウンし、他のDAQCard-AI-16E-4を同じスロットに挿して
URL:
http://digital.ni.com/public.nsf/allkb/9234AC7BDE2199CC86256EF3004DA25D
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
21
Previous
|
Next
Search KnowledgeBase Documents: