Reenumerar el Chasis PXI No Actualiza el Número de Mi Chasis en Mis Dispositivos RIO
Estoy utilizando algunos dispositivos de la Serie R en mi chasis PXI. Sin embargo, cuando reenumero mi chasis utilizando Measurement & Automation Explorer (MAX) y hago clic en mi dispositivo RIO que está en el chasis, el número del chasis no cambia. ¿Por qué es esto, y cómo puedo cambiarlo?
URL: http://digital.ni.com/public.nsf/allkb/6BF5B4F1D01A0C3A862575DE005B3ED1
|
Renumbering PXI Chassis Does not Update My Chassis Number in My RIO Devices
I am using some R-Series devices in my PXI chassis. However, when I renumber my chassis using Measurement & Automation Explorer (MAX) and click on my RIO device that is in that chassis, the chassis number does not change. Why is this, and how can I change it?
URL: http://digital.ni.com/public.nsf/allkb/3F16C8047A91C641862575DA0058D945
|
Why Can't I Monitor CPU Usage on a LabVIEW Real-Time Controller?
I want to monitor the CPU usage of a network-connected real-time controller using the Distributed System Manager. I selected the real-time target of interest from the tree in the left-hand window and then selected the Auto View tab at the bottom right of the window. Then I expected to visualize the
URL: http://digital.ni.com/public.nsf/allkb/FA5C65FF5645FA5A862575D30029B6E4
|
Switch Executive está Congelando Measurement & Automation Explorer (MAX)
Cuando selecciono una o más de mis configuraciones de Switch Executive en Measurement & Automation Explorer (MAX) para borrarlos o modificarlos, mi PC se congela o muestra otros síntomas de que mis configuraciones se han corrupto. ¿Cómo puedo removerlas fuera de MAX?
URL: http://digital.ni.com/public.nsf/allkb/E6E334FAD08CF17F862575DA00722701
|
Switch Executive is Freezing Measurement & Automation Explorer (MAX)
When I select one or more of my Switch Executive configurations in Measurement & Automation Explorer (MAX) to delete or modify them, my computer will freeze or give other symptoms that my configurations have become corrupted. How can I remove them outside of MAX?
URL: http://digital.ni.com/public.nsf/allkb/F16D4D73CD2946F2862575CC0058E701
|
Why does my Run/Stop bit not appear active while my motor is running?
When using the Read per Axis Status VI, I am seeing the Run/Stop bit on my motor not turn true while the motor is running. How can I adjust my settings to generate this behavior?
URL: http://digital.ni.com/public.nsf/allkb/797B98CAEF33FD25862575BA0068DE0E
|
How to Set CJC Source Attribute of the CJ Temperature channel with a cFP-TC-120
I have a cFP-TC 120 and I want to use a software algorithm for cold junction compensation. The FP-TC-120 and cFP-TC-120 Operating Instructions manual states that to perform this operation it is necessary to set the CJC Source attribute of the CJ Temperature channel to either 0° or 25°. Which
URL: http://digital.ni.com/public.nsf/allkb/9996F09082DAFFC0862575B70047F92F
|
How do I make a custom scale in the Measurement and Automation Explorer (MAX)?
I would like to make a custom scale in the Measurement & Automation Explorer to use with NI-DAQmx or NI Traditional DAQ in LabVIEW.
URL: http://digital.ni.com/public.nsf/allkb/3F6558112FD2C776862575B5004F7F87
|
Is It Possible To Import The Configuration .dss File Programmatically for My Datasocket Server Manager?
I need to import the .dss configuration file into the Datasocket Server Manager programmatically. I verified the methods associated with the Datasocket Server Manager's ActiveX but the only two actions allowed are About and Quit. Is it possible to import the configuration .dss file programmatically
URL: http://digital.ni.com/public.nsf/allkb/F59BBEC9FB6FD37C862575B500311263
|
Can I Create and Use VISA Aliases for My Instrument Simulator 2.0 in Multi-Instrument Mode?
I have the NI Instrument Simulator 2.0. Is it possible for me to create a VISA alias for each separate instrument while I am configured in multi-instrument mode?
URL: http://digital.ni.com/public.nsf/allkb/64D8AF607FB1CA8E862575A200624CE2
|