11-16 of 16
Glitchy Images when Acquiring from an IEEE for 1394 Camera Using IMAQdx When I grab images using the IMAQ for IEEE 1394 Cameras or IMAQdx drivers, portions of the video feed occasionally shift or glitch. If the camera outputs Bayer encoded images, the colors also change in the shifted areas as shown in the attached image [glitch bayer image/png]. How do I correct URL: http://digital.ni.com/public.nsf/allkb/F7D4BE3374F28EA1862572E500673889
Writing to Camera Registers with IMAQdx Takes Longer than with Native Camera Driver I am trying to repeatedly write to a register on a Firewire camera with the IMAQdx driver and notice that it takes a lot longer than when I write to the registers with a driver specifically built for the camera. This is especially noticed when trying to write to a 'trigger' register to perform URL: http://digital.ni.com/public.nsf/allkb/518FC152A5706D20862572D100678D71
Activation Error -1074364385 Occurs with an IEEE 1394 (FireWire) Camera I am either running a program that uses the IMAQ for IEEE 1394 Cameras driver or the IMAQdx driver, or running a script that uses these drivers. I keep getting error -1074364385 when trying to run my program. How can I fix this? URL: http://digital.ni.com/public.nsf/allkb/4170C20318D682ED862572B300835766
Does NI-IMAQdx have GigE Vision Camera Support for LabVIEW Real-Time? It seems that I can install NI-IMAQdx on to the RT system but I am not able to detect any cameras. Can I acquire images from GigE Vision cameras on an Real-Time system? URL: http://digital.ni.com/public.nsf/allkb/302F2B85712A7A2886257210005D6C59
Troubleshooting Tips for GigE Vision Cameras Where can I find troubleshooting tips as well as general information on GigE Vision cameras? URL: http://digital.ni.com/public.nsf/allkb/9B44E123EFBAB226862571E30066891C
How to Change the Name of a Firewire Camera in Measurement & Automation Explorer How can I change the name of my IEEE-1394 (Firewire) camera in Measurement & Automation Explorer (MAX) on my local system or my Compact Vision System (CVS)? URL: http://digital.ni.com/public.nsf/allkb/8B058C5DA21DA8938625716C007FCB5B
Sort by: