Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: Driver Software / NI-RIO [remove] ,
31-40 of 139
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Multifunction DAQ (MIO) (1)
Compact FieldPoint (3)
CompactDAQ (8)
CompactRIO (33)
Image Acquisition (IMAQ) (6)
Industrial Communications (3)
Reconfigurable I/O (RIO) (8)
Question Type
Bug Fix/ Error Message/ Error Code (56)
FAQ (19)
Install/Config (13)
Programming (23)
Specifications/ Documentation (11)
Unexpected Behavior/ Bad Reading (17)
Document Languages
English (81)
Spanish (7)
Japanese (10)
Chinese (Simplified) (22)
Chinese (Traditional) (9)
Korean (10)

Sort by:
31-40 of 139
|
IP Protection Options with CompactRIO How do I lock my application code to the hardware in a CompactRIO system? URL: http://digital.ni.com/public.nsf/allkb/E37E647F075FEFEB862573600005C805
How to Unmount an NI 9802 SD Card when the Handle has been Lost I've lost the handle of to the SD card that was mounted with LabVIEW Real-Time with the NI 9802. How do I Unmount an SD Card after the Handle has been lost? URL: http://digital.ni.com/public.nsf/allkb/F03D275B663F6587482573590058EA1C
Recommended Windows Disk Tools for Maintenance of Secure Digital (SD) Cards What are the recommended Windows Disk tools for maintenance of Secure Digital (SD) Cards for use with the NI 9802? URL: http://digital.ni.com/public.nsf/allkb/4998923F82F1F52C482573590058C667
Why is Incorrect Data Retuned When Communicating via Interactive Mode with NI-RIO 2.1.3 or Earlier? I Have and NI RIO application that performs array read/writes on a cRIO 901x controller that has NI RIO 2.3 and LabVIEW Real-Time 8.5 installed that returns incorrect data. When running in host interface mode, I get a LabVIEW Real-Time error about incompatible versions on the remote target URL: http://digital.ni.com/public.nsf/allkb/ACFAFB6C516C7C904825735300774D04
Why Does the Properties Dialog for CAN I/O Node in LabVIEW FPGA 8.5 Hang LabVIEW? If I try to change the data type for my FPGA CAN I/O node within LabVIEW FPGA 8.5, this will hang the LabVIEW user interface and I have to terminate LabVIEW using the Windows Task Manager. Why does this happen and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/5CE1747D0447614F8625734F006995E0
Earliest Software Support for the NI 9802 I recently purchased an NI 9802 module and I was directed to download and install NI-RIO 2.3.1 or later for the system to perform properly. However, I currently have NI-RIO 2.3 installed and I have been successful in using the NI 9802 module. Is it okay to continue to use NI-RIO 2.3 with the NI URL: http://digital.ni.com/public.nsf/allkb/E5CBFC3BDA775A3E4825734600774872
Manually Setting the Timeout Time for RPC connections for NI-RIO Targets I need to increase the timeout period for RPC connections to my cRIO controllers due to a slow internet connection. Is it possible to change this setting from MAX? URL: http://digital.ni.com/public.nsf/allkb/B746EA10EA65BE894825733D006BEA8F
Why Do I See Spurious Returns When Using Multiple Wait on IRQ Nodes on VxWorks Real Time Targets? The NI-RIO 2.3 driver with LabVIEW 8.5 supports multiple Wait on IRQ nodes in a single VI. Unfortunately, I see spurious returns from the Wait on IRQ Method Node when using cRIO-901x controllers. This does not occur on my cRIO-900x controllers or any other Pharlap based real-time controller. URL: http://digital.ni.com/public.nsf/allkb/A868BA261986A486482573380077794D
当我在VxWorks Real Time Targets环境下使用多个Wait on IRQ节点时,为何会得到假的返回值? NI-RIO 2.3搭配LabVIEW 8.5的使用可以支持在单一VI中使用多个Wait on IRQ节点。然而,当我使用CRIO-901x控制器时,会从"Wait on IRQ" 节点得到假的返回值。这个现象并不会发生在cRIO-9000x或其他Pharlap的Real-Time控制器。这个问题为何发生呢? URL: http://digital.ni.com/public.nsf/allkb/4F849B6417C2C27E862574DB00348222
當我在VxWorks Real Time Targets環境下使用多個Wait on IRQ節點時,為何會得到假的回傳值? NI-RIO 2.3搭配LabVIEW 8.5的使用可以支援在單一VI中使用多個Wait on IRQ節點。然而,當我使用CRIO-901x控制器時,會從"Wait on IRQ" 節點得到假的回傳值。這個現象並不會發生在cRIO-9000x或其他Pharlap的Real-Time控制器。這個問題發生的緣由為何呢? URL: http://digital.ni.com/public.nsf/allkb/95BC4E473B7C6313862573AD00070404
Sort by: