Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: Driver Software / NI-RIO [remove] ,
11-20 of 125
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Compact FieldPoint (3)
CompactDAQ (7)
CompactRIO (28)
Image Acquisition (IMAQ) (6)
Industrial Communications (1)
Multifunction DAQ (MIO) (1)
Reconfigurable I/O (RIO) (7)
Question Type
Bug Fix/ Error Message/ Error Code (52)
FAQ (17)
Install/Config (12)
Programming (20)
Specifications/ Documentation (8)
Unexpected Behavior/ Bad Reading (16)
Document Languages
English (73)
Spanish (5)
Japanese (10)
Chinese (Simplified) (19)
Chinese (Traditional) (8)
Korean (10)

Sort by:
11-20 of 125
|
NI-RIO 2.4 Full Recommended Software Set for Single-Board RIO Devices Does Not Include NI Serial and Modbus I/O Server I want to install the full recommended software set for NI-RIO 2.4 on a Single-Board RIO device. Unlike the software sets for the cRIO-901x, cRIO-900x, and cRIO-907x, the software set for Single-Board RIO devices does not include NI Serial or Modbus I/O Server. Why are those drivers missing from URL: http://digital.ni.com/public.nsf/allkb/4F46D4DEC02BA5D5862573AE007685E9
How to enable NI 9853/9852 C-Series module support on NI cRIO-9072 or cRIO-NI 9074 platforms? I got the following error message, if i try to install a NI985x CAN module on my NI cRIO-9072 or cRIO-NI 9074 device. The NI cRIO-9852 and NI cRIO-9853 C-Series modules are not supported on the NI cRIO-9072 or cRIO-NI 9074 platforms. Please visit ni.com/info and URL: http://digital.ni.com/public.nsf/allkb/C8284F895E607E1E862573A2006D7BA9
Using Fixed-Point Data with CompactRIO and LabVIEW FPGA In versions of NI-RIO prior to 2.4, C Series Modules only return binary (uncalibrated) data, which requires the host VI to apply calibration coefficients and convert the data to engineering units in software. After installing NI-RIO 2.4 or later, the default behavior for AI/AO modules is to URL: http://digital.ni.com/public.nsf/allkb/8C33AC9446631A2B862573A20083CB53
Using Fixed-Point Data with CompactRIO and LabVIEW FPGA In versions of NI-RIO prior to 2.4, C Series Modules only return binary (uncalibrated) data, which requires the host VI to apply calibration coefficients and convert the data to engineering units in software. After installing NI-RIO 2.4 or later, the default behavior for AI/AO modules is to URL: http://digital.ni.com/public.nsf/allkb/0294B7F0E28501B2862574470076D330
NI-RIO Error -63040 when using Open FPGA VI Reference from Host PC When attempting to Open an FPGA VI Reference from a host PC to an FPGA on a remote target I will often see the application error out because of an NI RIO communication Error -63040. The error message indicates that the device may not be accessible over the network, or that the NI URL: http://digital.ni.com/public.nsf/allkb/83DF7B9245541FC8862573A100597696
How Can I Reset the External Calibration Password for My 783x Board? I am following the NI 783xR Calibration Procedure for NI-RIO and when I get to the adjustment procedure and use the 783XR Calibration - Initialize External Calibration VI, I get the error: Error -2000 occurred at URL: http://digital.ni.com/public.nsf/allkb/8DB02D009C3C38088625737100744FA1
List of Bug Fixes for NI-RIO 2.3.1 The following items are the IDs and titles of a subset of issues fixed between NI-RIO 2.3 and NI-RIO 2.3.1. If you have a CAR ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-RIO. URL: http://digital.ni.com/public.nsf/allkb/46F1919F9C5E291486257369007D982E
Why Does My Real-Time Controller with NI-RIO and NI-Sync Crash? I have a real-time controller with NI-RIO 2.3 and NI-Sync 2.0.1 installed and the controller will not boot. Why does my controller crash when booting? URL: http://digital.ni.com/public.nsf/allkb/FECB7E15D5025002862573630012F384
IP Protection Options with CompactRIO How do I lock my application code to the hardware in a CompactRIO system? URL: http://digital.ni.com/public.nsf/allkb/E37E647F075FEFEB862573600005C805
How to Unmount an NI 9802 SD Card when the Handle has been Lost I've lost the handle of to the SD card that was mounted with LabVIEW Real-Time with the NI 9802. How do I Unmount an SD Card after the Handle has been lost? URL: http://digital.ni.com/public.nsf/allkb/F03D275B663F6587482573590058EA1C
Sort by: