Actual Excitation Voltage of NI 9237 Differs from Specified Voltage When creating a DAQmx Task for Strain or Custom Voltage with Excitation with the NI 9237, the excitation voltage that I specified in the task is not the same as I measure across Ex+ and Ex-. For example, URL: http://digital.ni.com/public.nsf/allkb/5CA74236A6A1919B862571D5005A41D0
NI 9237實際的激發電壓(Excitation Voltage)與指定的電壓不同 當使用 NI 9237 建立 Strain 或 Custom Voltage with Excitation 的 DAQmx Task 時,我所指定的激發電壓與我直接去量測 Ex+ 與 Ex- 的電壓值不同。舉例來說,若我指定激發電壓為 6V,而我所量測到在 Ex+ 與 Ex- 的壓差只有5 V。為什麼實際的激發電壓與指定的電壓 URL: http://digital.ni.com/public.nsf/allkb/D92F7641B906E9328625737D001BC48F
为什么我最新的cRIO模块不能被LabVIEW FPGA 1.1检测到? 我正在使用LabVIEW FPGA 1.1,同时我添加了最新的cRIO模块(NI 9203、9205等等,参看下面的链接)。当我进入'Embedded Project Manager'为CompactRIO配置目标并点击'Discover Modules'时,所有的老模块都能被发现,可是插有新模块的插槽却报告'Unknown'。我也尝试着在一个空槽中手动添 URL: http://digital.ni.com/public.nsf/allkb/9BDF588E0EFF24D748257172003A9D2A
Why Are My Newer cRIO Modules Not Detected By LabVIEW FPGA 1.1? I am using LabVIEW FPGA 1.1, and I have added one of the newer cRIO modules (NI 9203, 9205, etc. See list below) to my bank. When I go into the 'Embedded Project Manager' to Configure Target for CompactRIO and click 'Discover Modules', all of my older modules are found, but the slot that holds the URL: http://digital.ni.com/public.nsf/allkb/E98B9ADFB3AF05BC86257147004A2709
なぜ新しいcRIOのモジュールはLabVIEW FPGA 1.1で認識されないのですか? LabVIEW FPGA 1.1を使用して、新しいcRIOモジュール(NI 9203, 9205, 下記リスト参照)を追加しました。Embedded Project ManagerからCompactRIOの構成を行うために'Discover Modules'をクリックすると、以前購入したモジュールは表示されるものの、新しいモジュールがインストール URL: http://digital.ni.com/public.nsf/allkb/C0DAC6232E31F92E8625716F00391106
Temperature Readings With NI-9211 Are Off By Some Degrees When using the NI-9211 temperature module, I can see that there is a couple of degrees error at very high or very low temperatures. Why is this? URL: http://digital.ni.com/public.nsf/allkb/AAEC7BF96A019EFB862570E4006D9204
在某些溫度下用NI-9211讀取會有誤差 當使用NI-9211溫度模組時,我發現在非常高或非常低的溫度下會產生一些偏差,為什麼會這樣呢? URL: http://digital.ni.com/public.nsf/allkb/474077DD3B3F7E768625735B0041C466