21-30 of 75
|
S 시리즈 장비에서 동시 샘플링과 Hold SCXI 모듈 사용하기. 동시 샘플링 S 시리즈 장치로 동시 샘플링과 hold SCXI 모듈(SCXI-1140, 1520, 1530, or 1531 같은)을 사용하는 것이 가능합니까? URL: http://digital.ni.com/public.nsf/allkb/F99A1DCEFE707B3C8625714D00053889
Sシリーズデバイスで同時サンプルアンドホールドアンプ(SSH)モジュールを使用する方法に関して SCXI-1140や1520、1530、1531などの同時サンプルアンドホールドアンプ(SSH)モジュールを、Sシリーズデバイスで使用することは可能でしょうか。 URL: http://digital.ni.com/public.nsf/allkb/88D4F061BD4D26AF862571E300261CE0
Using Simultaneous Sample and Hold SCXI Modules with an S Series Device Is it possible to use a simultaneous sample and hold SCXI module (such as the SCXI-1140, 1520, 1530, or 1531) with a simultaneous sampling S Series device? Do I have to disable the sample and hold circuitry? URL: http://digital.ni.com/public.nsf/allkb/EBB8C362E138233E86257141006BC944
How to do a Null-Offset Calibration for Full-Bridge Absolute Transducers (SCXI-1520 / PXI-4220) with the DAQ Assistant? The DAQ Assistant does not provide a way to do any calibration for Full-Bridge Absolute Transducers that are not strain gauges (for example load cells) for a NI-DAQmx Tasks / Global Channels created in MAX.If I use the example VI located in the example finder ( Browse According to URL: http://digital.ni.com/public.nsf/allkb/3593FEAB432C2B0C8625713E0059E5E9
Error -200320 at DAQmx Start Task with a SCXI System When I try and run my DAQmx program with my SCXI system I get the following error -200320:Why do I get this error and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/F5529A0EF8ADDA288625713400613065
Error -200320 en DAQmx Start Task con un Sistema SCXI Cuando intento correr mi programa de DAQmx con mi sistema SCXI obtengo el siguiente error -200320: ¿Por qué obtengo este URL: http://digital.ni.com/public.nsf/allkb/2A62835291072B9B8625747300686AC3
Conflicting Range Values in Thermocouple Task Cause Error -200077 When the maximum and minimum values specified as the temperature range of a thermocouple task exceed the range of values used when calibrating that channel using the DAQ Assistant, the thermocouple task returns error -200077. For example, a calibration file is created for a particular URL: http://digital.ni.com/public.nsf/allkb/440EB533229211CD8625711C007E61B3
Conflicto en los Valores del Rango en una Tarea de Termopares Causa el Error -200077 Cuando los valores máximos y mínimos especificados como el rango de temperatura de una tarea de un termopar exceden el rango de valores utilizados al calibrar dicho URL: http://digital.ni.com/public.nsf/allkb/63C3E4ACC8A5FBD78625738400067478
Calibrate SCXI Modules with NI-DAQmx Problem: Can I use NI-DAQmx calls to calibrate my SCXI modules? Solution: With NI-DAQmx 8.0 and later you can calibrate some SCXI modules. As of DAQmx 8. URL: http://digital.ni.com/public.nsf/allkb/DAC4C20C9AE291A4862570E5006B0F3C
SCXI-1520 Hardware Offset Nulling Fails with 'out of range' Error I tried to use the offset nulling feature of my SCXI-1520, but it fails with an error that says the measurement is too far out of range. How else can I null my measurement offset? URL: http://digital.ni.com/public.nsf/allkb/30D6D29F67104C4E8625709A004BA510