Software
NI-DAQ
(46)
NI-DAQmx
(34)
NI-DAQmx Base
(2)
NI-SWITCH
(1)
Hardware
Chassis
(7)
Modules
(44)
Terminal Blocks
(6)
Question Type
Bug Fix/ Error Message/ Error Code
(7)
FAQ
(8)
Install/Config
(6)
Programming
(20)
Specifications/ Documentation
(23)
Unexpected Behavior/ Bad Reading
(11)
Document Languages
English
(51)
Spanish
(2)
French
(1)
Japanese
(4)
Chinese (Simplified)
(9)
Chinese (Traditional)
(2)
Korean
(6)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
21-30 of
75
Previous
|
Next
S 시리즈 장비에서 동시 샘플링과 Hold SCXI 모듈 사용하기.
동시 샘플링 S 시리즈 장치로 동시 샘플링과 hold SCXI 모듈(SCXI-1140, 1520, 1530, or 1531 같은)을 사용하는 것이 가능합니까?
URL:
http://digital.ni.com/public.nsf/allkb/F99A1DCEFE707B3C8625714D00053889
Sシリーズデバイスで同時サンプルアンドホールドアンプ(SSH)モジュールを使用する方法に関して
SCXI-1140や1520、1530、1531などの同時サンプルアンドホールドアンプ(SSH)モジュールを、Sシリーズデバイスで使用することは可能でしょうか。
URL:
http://digital.ni.com/public.nsf/allkb/88D4F061BD4D26AF862571E300261CE0
Using Simultaneous Sample and Hold SCXI Modules with an S Series Device
Is it possible to use a simultaneous sample and hold SCXI module (such as the SCXI-1140, 1520, 1530, or 1531) with a simultaneous sampling S Series device? Do I have to disable the sample and hold circuitry?
URL:
http://digital.ni.com/public.nsf/allkb/EBB8C362E138233E86257141006BC944
How to do a Null-Offset Calibration for Full-Bridge Absolute Transducers (SCXI-1520 / PXI-4220) with the DAQ Assistant?
The DAQ Assistant does not provide a way to do any calibration for Full-Bridge Absolute Transducers that are not strain gauges (for example load cells) for a NI-DAQmx Tasks / Global Channels created in MAX.If I use the example VI located in the example finder ( Browse According to
URL:
http://digital.ni.com/public.nsf/allkb/3593FEAB432C2B0C8625713E0059E5E9
Error -200320 at DAQmx Start Task with a SCXI System
When I try and run my DAQmx program with my SCXI system I get the following error -200320:Why do I get this error and how can I fix it?
URL:
http://digital.ni.com/public.nsf/allkb/F5529A0EF8ADDA288625713400613065
Error -200320 en DAQmx Start Task con un Sistema SCXI
Cuando intento correr mi programa de DAQmx con mi sistema SCXI obtengo el siguiente error -200320: ¿Por qué obtengo este
URL:
http://digital.ni.com/public.nsf/allkb/2A62835291072B9B8625747300686AC3
Conflicting Range Values in Thermocouple Task Cause Error -200077
When the maximum and minimum values specified as the temperature range of a thermocouple task exceed the range of values used when calibrating that channel using the DAQ Assistant, the thermocouple task returns error -200077. For example, a calibration file is created for a particular
URL:
http://digital.ni.com/public.nsf/allkb/440EB533229211CD8625711C007E61B3
Conflicto en los Valores del Rango en una Tarea de Termopares Causa el Error -200077
Cuando los valores máximos y mínimos especificados como el rango de temperatura de una tarea de un termopar exceden el rango de valores utilizados al calibrar dicho
URL:
http://digital.ni.com/public.nsf/allkb/63C3E4ACC8A5FBD78625738400067478
Calibrate SCXI Modules with NI-DAQmx
Problem: Can I use NI-DAQmx calls to calibrate my SCXI modules? Solution: With NI-DAQmx 8.0 and later you can calibrate some SCXI modules. As of DAQmx 8.
URL:
http://digital.ni.com/public.nsf/allkb/DAC4C20C9AE291A4862570E5006B0F3C
SCXI-1520 Hardware Offset Nulling Fails with 'out of range' Error
I tried to use the offset nulling feature of my SCXI-1520, but it fails with an error that says the measurement is too far out of range. How else can I null my measurement offset?
URL:
http://digital.ni.com/public.nsf/allkb/30D6D29F67104C4E8625709A004BA510
Sort by:
Date (Most recent)
Title (A-Z)
21-30 of
75
Previous
|
Next