KnowledgeBase [see results below]. To refine your results, select another category.
Software
NI-DAQ (1)
NI-DAQmx (6)
Hardware
Carriers (3)
Modules (5)
Question Type
Install/Config (1)
Programming (1)
Specifications/ Documentation (3)
Unexpected Behavior/ Bad Reading (2)
Document Languages
English (4)
Spanish (1)
Japanese (1)
Chinese (Simplified) (1)

Sort by:
1-7 of 7
Medición con RTD01 y Sensado Remoto (Remote Sensing) En el manual del SCC RTD01 vienen dos formas para la conexión de 3 cables: 3 cables-1 canal y 3 cables con sensado remoto (remote sensing). Al hacer la configuración de un canal de lectura para estos canales en MAX, no aparece una forma de especificar remote sensing ¿Cómo puedo medir con la URL: http://digital.ni.com/public.nsf/allkb/47EE5F88C1762D8F862571D90003E470
Inconsistent Temperature Readings Between Multiple Channels In NI-DAQmx Tasks I created a DAQmx Temperature task to take readings from multiple thermocouple channels. On the Thermocouple Setup screen, I set the Thermocouple Type according to my sensor, as seen in the following image: URL: http://digital.ni.com/public.nsf/allkb/D40CC052881A5B708625715600720C22
NI-DAQmx 任务多通道间温度读数的不一致 我创建了一个 DAQmx 温度任务从多个热电欧通道上读取温度值。在热电欧建立窗口,我根据我的传感器类型设置热电欧类型,如下图所示:< URL: http://digital.ni.com/public.nsf/allkb/DB8CE3BDD79D0951862571990022D7F9
How Do I Program a DAQmx TEDS Task in LabVIEW? I know how to set up DAQmx tasks and global channels in Measurement and Automation Explorer (MAX) to use my TEDS-enabled sensors, but I want to do it programmatically in LabVIEW. Is there any way to set-up my TEDS DAQmx channels directly in LabVIEW? URL: http://digital.ni.com/public.nsf/allkb/CE93FAB3AA03809686256F7A004AB8B0
SCC-RLY01 はNI-DAQmxでサポートされていますか? NI-DAQ 7.0 を使用し、2つのSCC-RLY01をSC-2345で設定を行おうとしましたが、ドロップダウンリストに表示されません。SCC-RLY01をDAQmxで使用することはできますか? URL: http://digital.ni.com/public.nsf/allkb/AA5A1C0DFD11B90F8625700C0048F8B5
Support for SCC-RLY-01 with NI-DAQmx I have NI-DAQ 7.0 installed and am trying to configure my SC-2345 with two SCC-RLY01 modules, but they do not appear as options. Can I use the SCC-RLY01 with NI-DAQmx? URL: http://digital.ni.com/public.nsf/allkb/9F9522340F8B1A5586256E7C006608C4
What SCC Modules are Supported in NI-DAQ 6.6.0 for Mac OS? Problem: I need a list of the SCC modules that are supported in Mac OS. Solution: Here are the devices supported in NI-DAQ 6.6.0 for Mac OS. Please check the release notes of any future versions of NI-DAQ for changes. URL: http://digital.ni.com/public.nsf/allkb/E829D318E7F2890786256BA50069049E
Sort by: