在P-command Drive上使用非7390的运动控制卡 我的7330/7340/7350运动控制卡,在MAX中配置闭环步进模式,它连接到了一个P-Command驱动器。每次运动时,编码器反馈都会显示电机偏离了一点位置 URL: http://digital.ni.com/public.nsf/allkb/44AAD965CC678E778625740000186901
Reading the UMI-7764/7774’s Inhibit All Line Status Can I read the UMI-7764 or UMI-7774’s Inhibit All input line status with NI-Motion? URL: http://digital.ni.com/public.nsf/allkb/F09914A1561EFBC5862571CC006D7521
讀取UMI-7764/7774的Inhibit All Line的狀態 我可以使用NI-Motion讀取在UMI-7764或UMI-7774上的Inhibit All input line的狀態嗎? URL: http://digital.ni.com/public.nsf/allkb/E12496F118D1A7678625740C0006C096
モーションボードでのアナログ入力とデジタル入力の速度 モーションボードのアナログ入力とデジタル入力を使おうと考えています。マニュアルにはサンプリングレートの記述がありません。サンプリングレートはどうなっていますか? URL: http://digital.ni.com/public.nsf/allkb/73AEE4AE62F410BB8625714E0021EC7B
Inhibit Input Setting in MAX is Grayed Out In Measurement and Automation Explorer (MAX), under Devices and Interfaces » NI-Motion Devices » PCI 73xx » Default 73xx Settings » Axis 1 » on the Motion I/O Settings folder there is a setting for Inhibit Input Settings, but it is always grayed out. Why is this setting grayed out? Is URL: http://digital.ni.com/public.nsf/allkb/01CE29B6175371118625714C0058C2B1
Set ADC Range On Motion Controller I am trying to read an analog voltage on my motion controller using the Read ADC VI. I use the Set ADC Range VI to change the voltage range, but it does not change the value I am reading. Why is the Set ADC Range VI not working and not returning an error? URL: http://digital.ni.com/public.nsf/allkb/DACB60F333807FF4862571330059C012
設定運動控制器的ADC範圍 我目前正嘗試使用Read ADC VI來讀取運動控制器上的類比輸入電壓值。我呼叫Set ADC Range VI來改變電壓輸入範圍,但是這樣並不會改變我所接收的電壓讀取值。為什麼Set ADC Range VI沒有發揮作用,但卻也沒有錯誤訊息的回傳呢? URL: http://digital.ni.com/public.nsf/allkb/DCD623F7AAA53012862574970051F98B
모션 컨트롤러에서 Set ADC Range Read ADC VI를 사용하여 모션 컨트롤러에서 아날로그 전압을 측정하려고 합니다. Set ADC Range VI 를 이용하여 전압범위를 바꾸어 주는데 측정하는 값이 변하지 않습니다. Set ADC Range VI 가 왜 동작하지 않고 에러를 발생합니까? URL: http://digital.ni.com/public.nsf/allkb/703C55F6899C682A862571410001EA9C
Why Do I Need Limit Switches to Find the Home Position? My motion setup provides a signal for the home switch, but no limit switches. Can I use the Find Reference functions in this setup? URL: http://digital.ni.com/public.nsf/allkb/0806A5F3E582AE448625711D000CEA9D
왜 홈(Home) 위치를 찾는데 Limit 스위치가 필요합니까? 모션 설정에서 홈 스위치에 대한 신호가 있습니다. 그러나 Limit 스위치는 없습니다. 이 설정에서 Find Reference 함수를 사용할수 있습니까? URL: http://digital.ni.com/public.nsf/allkb/3630DFE6969FDF778625724C0023DF16